An international, cross-sectional survey of the management of Vancouver type B1 periprosthetic femoral fractures around total hip arthroplasties

被引:16
|
作者
Bates, Brent D. [1 ]
Walmsley, David W. [2 ]
Vicente, Milena R. [2 ]
Kuzyk, Paul R. [3 ]
Nauth, Aaron [1 ,2 ]
Waddell, James P. [2 ]
McKee, Michael D. [2 ]
Schemitsch, Emil H. [4 ]
机构
[1] Univ Toronto, St Michaels Hosp, Keenan Res Ctr Biomed Sci, Toronto, ON, Canada
[2] Univ Toronto, St Michaels Hosp, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
[3] Univ Toronto, Mt Sinai Hosp, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
[4] Western Univ, London Hlth Sci Ctr, Dept Surg, London, ON, Canada
关键词
Total hip arthroplasty; Periprosthetic fracture; Vancouver type B1; Locking plate; Strut allograft; Survey; WELL-FIXED IMPLANTS; SHAFT FRACTURES; PLATE FIXATION; ONLAY ALLOGRAFTS; FEMUR FRACTURES; STRUT ALLOGRAFT; REDUCTION; ALGORITHM; STEM;
D O I
10.1016/j.injury.2017.10.034
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The incidence of periprosthetic femoral fractures around total hip arthroplasties is increasing. Fractures around a stable implant stem (Vancouver type B1) are among the most common of these fractures. Various fixation strategies for Vancouver type B1 periprosthetic fractures have been reported in the literature; however, little high-level evidence exists. This study was designed to determine the current management strategies and opinions among orthopaedic surgeons treating Vancouver type B1 periprosthetic femoral fractures, and to evaluate the need for a large prospective randomized controlled trial for the management of these injuries. Methods: Orthopaedic surgeon members of the Orthopaedic Trauma Association (OTA), the Canadian Orthopaedic Association (COA), and the Hip Society were invited to participate in a 51-item web-based survey surrounding the management of periprosthetic femoral fractures around total hip replacements, as well as the perceived need for future research in this area. Responses were summarized using proportions, and further stratified by practice type, case volume, surgeon age, and fellowship training. Results: For Vancouver type B1 fractures, open reduction and internal fixation (ORIF) with locked plating was favoured slightly over ORIF with cable plating +/- cortical strut allograft (51.1% versus 45.5%). When compared to cable plating with cortical strut allograft, respondents believed that isolated locked plating resulted in lower nonunion and reoperation rates, but similar infection and malunion rates. Subgroup analyses revealed that practice type, surgeon age, case volume, and fellowship training influenced surgeons' management of periprosthetic femoral fractures and beliefs regarding complications. There is high demand for a large prospective randomized controlled trial for Vancouver type B1 fracture fixation. Conclusions: Consensus surrounding the management of Vancouver type B1 periprosthetic femoral fractures is lacking, and there is a perceived need among orthopaedic surgeons for a large prospective randomized controlled trial in order to define the optimal management of these injuries. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:364 / 369
页数:6
相关论文
共 50 条
  • [31] Surgical outcomes of cable plate fixation in treatment of Vancouver type B1 and type C periprosthetic femoral fractures: a retrospective case series
    Sen, Cengiz
    Kizilkurt, Taha
    Demirel, Mehmet
    Yildirim, Ahmet Mucteba
    Saglam, Yavuz
    Ozturk, Irfan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (04) : 235 - 243
  • [32] Vancouver type B2 and B3 periprosthetic fractures treated with revision total hip arthroplasty
    Tomas Amenabar
    Wael A. Rahman
    Vineet V. Avhad
    Ramiro Vera
    Allan E. Gross
    Paul R. Kuzyk
    International Orthopaedics, 2015, 39 : 1927 - 1932
  • [33] Vancouver type B2 and B3 periprosthetic fractures treated with revision total hip arthroplasty
    Amenabar, Tomas
    Rahman, Wael A.
    Avhad, Vineet V.
    Vera, Ramiro
    Gross, Allan E.
    Kuzyk, Paul R.
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (10) : 1927 - 1932
  • [34] Locking Compression Plate and Cerclage Band for Type B1 Periprosthetic Femoral Fractures
    Xue, Huaming
    Tu, Yihui
    Cai, Minwei
    Yang, Anli
    JOURNAL OF ARTHROPLASTY, 2011, 26 (03): : 467 - 471
  • [35] Outcomes of Vancouver B2 and B3 periprosthetic femoral fractures after total hip arthroplasty in elderly patients
    Moreta, Jesus
    Uriarte, Iker
    Ormaza, Amaia
    Mosquera, Javier
    Iza, Kattalin
    Aguirre, Urko
    Jose Legarreta, Maria
    Luis Martinez-De Los Mozos, Jose
    HIP INTERNATIONAL, 2019, 29 (02) : 184 - 190
  • [36] Hip revision arthroplasty for failed osteosynthesis in periprosthetic Vancouver type B1 fractures using a cementless, modular, tapered revision stem
    Fink, B.
    Oremek, D.
    BONE & JOINT JOURNAL, 2017, 99B (04): : 11 - 16
  • [37] Letter to the Editor on "Predictors of Perioperative Vancouver B Periprosthetic Femoral Fractures Associated With the Direct Anterior Approach to Total Hip Arthroplasty"
    Adriana Galvis, Luz
    Castano, Juliana
    Suarez, Cristina
    Bonilla, Guillermo
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : 1752 - 1753
  • [38] Locking compression plate versus revision-prosthesis for Vancouver type B2 periprosthetic femoral fractures after total hip arthroplasty
    Joestl, Julian
    Hofbauer, Marcus
    Lang, Nikolaus
    Tiefenboeck, Thomas
    Hajdu, Stefan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (04): : 939 - 943
  • [39] The management of Vancouver B1 and C periprosthetic fractures: radiographic and clinic outcomes of a monocentric consecutive series
    Ciriello, Vincenzo
    Chiarpenello, Roberto
    Tomarchio, Alessandro
    Marra, Francesco
    Egidio, Antonio Carmine
    Piovani, Lucio
    HIP INTERNATIONAL, 2020, 30 (2_SUPPL) : 94 - 100
  • [40] Periprosthetic fracture fixation in Vancouver B1 femoral shaft fractures: A biomechanical study comparing two plate systems
    Waehnert, Dirk
    Mueller, Marcus
    Tiedemann, Hendrik
    Maerdian, Sven
    Raschke, Michael J.
    Koesters, Clemens
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 24 : 150 - 154