In vivo optical coherence tomography (OCT) in periocular basal cell carcinoma: correlations between in vivo OCT images and postoperative histology

被引:12
|
作者
Pelosini, Lucia [1 ]
Smith, Henry Barnabas [1 ]
Schofield, John B. [2 ]
Meeckings, Adam [3 ]
Dhital, Anish [1 ]
Khandwala, Mona [1 ]
机构
[1] Maidstone & Tunbridge Wells NHS Trust, Dept Ophthalmol, Maidstone ME16 9QQ, Kent, England
[2] Maidstone & Tunbridge Wells NHS Trust, Dept Histopathol, Maidstone ME16 9QQ, Kent, England
[3] Michelson Diagnost Ltd, Orpington, Kent, England
关键词
THICKNESS MEASUREMENT; MICROGRAPHIC SURGERY; SKIN; ULTRASOUND; EXCISION; FACE;
D O I
10.1136/bjophthalmol-2012-303043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To investigate in vivo optical coherence tomography (OCT) for imaging of periocular basal cell carcinoma (BCC). Methods Consecutive patients with periocular BCC were prospectively investigated with VivoSight OCT imaging prior to surgical excision. Histology sections were compared with OCT images with regard to lesion measurements (x, y and z dimensions) and histological features. Results A total of 15 patients with biopsy proven BCC were recruited. The OCT horizontal margins correlated positively with histology (r=0.8 and 0.66, x and y axes) and could be identified in 3/15 (x axis) and 6/15 (y axis) cases. The vertical margin correlation was r=0.43 and BCC depth could be measured in 9/15 cases. The following histological features of BCC could be identified on OCT images: (1) lobular pattern (100%); (2) dilated blood vessels (80%); (3) reflective margins of tumour lobules (100%); and (4) epidermal thinning overlying BCC lobules (100%). Conclusions This study indicated a strong positive correlation between the margins of periocular BCCs measured using in vivo OCT and histology, and a weak positive correlation with depth of invasion. VivoSight OCT produced high resolution images of BCC morphology. The limitations in horizontal margin measurements could potentially be overcome by design modification of the scanning probe.
引用
收藏
页码:890 / 894
页数:5
相关论文
共 50 条
  • [21] Creation of composite optical coherence tomography (OCT) images.
    Liebmann, JM
    Ishikawa, H
    Piette, S
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S131 - S131
  • [22] Lateral Resolution Improvement in Optical Coherence Tomography (OCT) Images
    Bousi, Evgenia
    Pitris, Costas
    IEEE 12TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS & BIOENGINEERING, 2012, : 599 - 602
  • [23] Combined multimodal photoacoustic tomography, optical coherence tomography (OCT) and OCT based angiography system for in vivo imaging of multiple skin disorders in human
    Liu, Mengyang
    Chen, Zhe
    Sinz, Christoph
    Rank, Elisabet
    Zabihian, Behrooz
    Zhang, Edward Z.
    Beard, Paul C.
    Kittler, Harald
    Drexler, Wolfgang
    PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY, 2017, 10037
  • [24] Endoscopic optical coherence tomography (OCT) and autofluorescence imaging (AFI) of ex vivo fallopian tubes
    Malone, Jeanie
    Hohert, Geoffrey
    Hoang, Lien
    Miller, Dianne M.
    McAlpine, Jeßica
    Macaulay, Calum
    Lane, Pierre
    Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 2020, 11232
  • [25] One-micron resolution optical coherence tomography (OCT) in vivo for cellular level imaging
    Cui, Dongyao
    Liu, Xinyu
    Zhang, Jing
    Yu, Xiaojun
    Ding, Sun
    Luo, Yuemei
    Gui, Jun
    Shum, Ping
    Liu, Linbo
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIX, 2015, 9312
  • [26] Encrustation of urologic double pigtail catheters—an ex vivo optical coherence tomography (OCT) study
    Markus J. Bader
    Katja Zilinberg
    Patrick Weidlich
    Raphaela Waidelich
    Michaela Püls
    Christian Gratzke
    Christian G. Stief
    Herbert Stepp
    Ronald Sroka
    Lasers in Medical Science, 2013, 28 : 919 - 924
  • [27] In vivo imaging of human primordial follicles and growing follicles by new optical coherence tomography (OCT)
    Zhang, R.
    Law, T. S. M.
    Chung, J. P. W.
    Li, T. C.
    Wang, C. C.
    HUMAN REPRODUCTION, 2019, 34 : 60 - 60
  • [28] High-resolution Optical Coherence Tomography (OCT) Imaging of Human Kidney Ex Vivo
    Duttaroy, Anik
    Paek, Andrew
    Onozato, Maristela
    Shirmahamoodi, Bobak
    Jiang, James
    Cable, Alex
    Andrews, Peter M.
    Chen, Yu
    2009 35TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2009, : 40 - +
  • [29] Endoscopic Optical Coherence Tomography (OCT) and Autofluorescence Imaging (AFI) of ex vivo Fallopian Tubes
    Malone, Jeanie
    Hohert, Geoffrey
    Hoang, Lien
    Miller, Dianne M.
    McAlpine, Jessica N.
    MacAulay, Calum E.
    Lane, Pierre M.
    MULTIMODAL BIOMEDICAL IMAGING XV, 2020, 11232
  • [30] High-Sensitivity Contrast-Enhanced in vivo Imaging with Optical Coherence Tomography (OCT)
    Liba, Orly
    SoRelle, Elliott D.
    Sen, Debasish
    de la Zerda, Adam
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2017,