Investigation of gated cone-beam CT to reduce respiratory motion blurring

被引:17
|
作者
Kincaid, Russell E., Jr. [1 ]
Yorke, Ellen D. [1 ]
Goodman, Karyn A. [2 ]
Rimner, Andreas [2 ]
Wu, Abraham J. [2 ]
Mageras, Gig S. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
关键词
image guided radiation therapy; cone-beam CT; respiratory motion; motion management; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; LUNG-TUMORS; QUALITY-ASSURANCE; CANCER; LIVER;
D O I
10.1118/1.4795336
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Methods of reducing respiratory motion blurring in cone-beam CT (CBCT) have been limited to lung where soft tissue contrast is large. Respiration-correlated cone-beam CT uses slow continuous gantry rotation but image quality is limited by uneven projection spacing. This study investigates the efficacy of a novel gated CBCT technique. Methods: In gated CBCT, the linac is programmed such that gantry rotation and kV image acquisition occur within a gate around end expiration and are triggered by an external respiratory monitor. Standard CBCT and gated CBCT scans are performed in 22 patients (11 thoracic, 11 abdominal) and a respiration-correlated CT (RCCT) scan, acquired on a standard CT scanner, from the same day serves as a criterion standard. Image quality is compared by calculating contrast-to-noise ratios (CNR) for tumors in lung, gastroesophageal junction (GEJ) tissue, and pancreas tissue, relative to surrounding background tissue. Congruence between the object in the CBCT images and that in the RCCT is measured by calculating the optimized normalized cross-correlation (NCC) following CBCT-to-RCCT rigid registrations. Results: Gated CBCT results in reduced motion artifacts relative to standard CBCT, with better visualization of tumors in lung, and of abdominal organs including GEJ, pancreas, and organs at risk. CNR of lung tumors is larger in gated CBCT in 6 of 11 cases relative to standard CBCT. A paired two-tailed t-test of lung patient mean CNR shows no statistical significance (p = 0.133). In 4 of 5 cases where CNR is not increased, lung tumor motion observed in RCCT is small (range 1.3-5.2 mm). CNR is increased and becomes statistically significant for 6 out of 7 lung patients with > 5 mm tumor motion (p = 0.044). CNR is larger in gated CBCT in 5 of 7 GEE cases and 3 of 4 pancreas cases (p = 0.082 and 0.192). Gated CBCT yields improvement with lower NCC relative to standard CBCT in 10 of 11, 7 of 7, and 3 of 4 patients for lung, GEJ, and pancreas images, respectively (p = 0.0014, 0.0030, 0.165). Conclusions: Gated CBCT reduces image blurring caused by respiratory motion. The gated gantry rotation yields uniformly and closely spaced projections resulting in improved reconstructed image quality. The technique is shown to be applicable to abdominal sites, where image contrast of soft tissues is low. (C) 2013 American Association of Physicists in Medicine. [http ://dx.doi.org/10.1118/1.4795336]
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Motion compensation for cone-beam CT using Fourier consistency conditions
    Berger, M.
    Xia, Y.
    Aichinger, W.
    Mentl, K.
    Unberath, M.
    Aichert, A.
    Riess, C.
    Hornegger, J.
    Fahrig, R.
    Maier, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17): : 7181 - 7215
  • [42] Motion artefact reduction for exact cone-beam CT reconstruction algorithms
    Koken, P
    Köhler, T
    Bontus, C
    Proksa, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2985 - 2988
  • [43] Convolutional Network Based Motion Artifact Reduction in Cone-Beam CT
    Paysan, P.
    Strzelecki, A.
    Arrate, F.
    Munro, P.
    Scheib, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E340 - E341
  • [44] Motion blurring correction for a cone beam CT system with image decomposition and deconvolution method
    Yang, K.
    Boone, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2572 - 2572
  • [45] A new weighting scheme for cone-beam helical CT to reduce the image noise
    Taguchi, K
    Chiang, BSS
    Silver, MD
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2351 - 2364
  • [46] Respiratory Motion Estimation from Cone-Beam Projections Using a Prior Model
    Vandemeulebroucke, Jef
    Kybic, Jan
    Clarysse, Patrick
    Sarrut, David
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT II, PROCEEDINGS, 2009, 5762 : 365 - +
  • [47] Comparative study of respiratory motion correction techniques in cone-beam computed tomography
    Rit, Simon
    Nijkamp, Jasper
    van Herk, Marcel
    Sonke, Jan-Jakob
    RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) : 356 - 359
  • [48] Crescent artifacts in cone-beam CT
    Giles, William
    Bowsher, James
    Li, Hao
    Yin, Fang-Fang
    MEDICAL PHYSICS, 2011, 38 (04) : 2116 - 2121
  • [49] Towards cone-beam CT thermometry
    Li, Ming
    Abi-Jaoudeh, Nadine
    Kapoor, Ankur
    Kadoury, Samuel
    Xu, Sheng
    Noordhoek, Niels
    Radaelli, Alessandro
    Carelsen, Bart
    Wood, Bradford J.
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [50] Clinical implementation of a cone-beam CT
    Betgen, A
    van Herk, M
    Remeijer, P
    Sonke, JJ
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S158 - S158