Measurement of the radon concentration in purified water in the Super-Kamiokande IV detector

被引:18
|
作者
Nakano, Y. [1 ]
Hokama, T. [2 ]
Matsubara, M. [3 ]
Miwa, M. [4 ]
Nakahata, M. [5 ,6 ]
Nakamura, T. [7 ]
Sekiya, H. [5 ,6 ]
Takeuchi, Y. [1 ,6 ]
Tasaka, S. [5 ]
Wendell, R. A. [6 ,8 ]
机构
[1] Kobe Univ, Grad Sch Sci, Dept Phys, Kobe, Hyogo 6578501, Japan
[2] Japan Atom Energy Agcy, Nucl Emergency Assistance & Training Ctr, Ibaraki 3111206, Japan
[3] Gifu Univ, Head Off Informat & Management, Gifu 5011193, Japan
[4] Gifu Univ, Life Sci Res Ctr, Div Radioisotope Expt, Gifu 5011193, Japan
[5] Univ Tokyo, Inst Cosm Ray Res, Kamioka Observ, Gifu 5061205, Japan
[6] Univ Tokyo, Inst Adv Study, Kavli Inst Phys & Math Universe WPI, Kashiwa, Chiba 2778583, Japan
[7] Gifu Univ, Fac Educ, Dept Phys, Gifu 5011193, Japan
[8] Kyoto Univ, Dept Phys, Kyoto, Kyoto 6068502, Japan
关键词
Super-Kamiokande; Radon; Solar neutrino; Charcoal; Radon extraction column; SYSTEM; RN-222; ADSORPTION; NEUTRINOS; OSCILLATIONS; CALIBRATION; MATTER; GAS;
D O I
10.1016/j.nima.2020.164297
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The radioactive noble gas radon can be a serious background source in the underground particle physics experiments studying processes that deposit energy comparable to its decay products. Low energy solar neutrino measurements at Super-Kamiokande suffer from these backgrounds and therefore require precise characterization of the radon concentration in the detector's ultra-pure water. For this purpose, we have developed a measurement system consisting of a radon extraction column, a charcoal trap, and a radon detector. In this article we discuss the design, calibration, and performance of the radon extraction column. We also describe the design of the measurement system and evaluate its performance, including its background. Using this system we measured the radon concentration in Super-Kamiokande's water between May 2014 and October 2015. The measured radon concentration in the supply lines of the water circulation system was 1.74 +/- 0.14 mBq/m(3) and in the return line was 9.06 +/- 0.58 mBq/m(3). Water sampled from the center region of the detector itself had a concentration of < 0.23 mBq/m(3) (95% C.L.) and water sampled from the bottom region of the detector had a concentration of 2.63 +/- 0.22 mBq/m(3).
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Identification problems of muon and electron events in the Super-Kamiokande detector
    Mitsui, K
    Kitamura, T
    Wada, T
    Okei, K
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2003, 29 (09) : 2281 - 2290
  • [22] High-energy neutrino astronomy with the Super-Kamiokande detector
    Habig, A.
    PROCEEDINGS OF THE 29TH INTERNATIONAL COSMIC RAY CONFERENCE VOL 9: HE 2, 2005, : 267 - 270
  • [23] Results on neutrino mass from the Super-Kamiokande detector.
    Sobel, HW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U67 - U67
  • [24] Direct measurement of supernova neutrino emission parameters with a gadolinium-enhanced Super-Kamiokande detector
    Yuksel, Hasan
    Ando, Shin'ichiro
    Beacom, John F.
    PHYSICAL REVIEW C, 2006, 74 (01):
  • [25] Low energy radioactivity BG model in Super-Kamiokande detector from SK-IV data
    Pronost, Guillaume
    37TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2021, 2022,
  • [26] Identification of Neutron Produced from ν Interactions with Water and Its Physics Application at Super-Kamiokande IV
    Chen, Shaomin
    12TH INTERNATIONAL CONFERENCE ON TOPICS IN ASTROPARTICLE AND UNDERGROUND PHYSICS (TAUP 2011), PTS 1-6, 2012, 375
  • [27] Development of Super-Kamiokande detector simulation based on Geant4
    Harada, M.
    Koshio, Y.
    Hagiwara, K.
    36TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2019, 2021,
  • [28] Measurement of atmospheric neutrino oscillation parameters by Super-Kamiokande I
    Ashie, Y
    Hosaka, J
    Ishihara, K
    Itow, Y
    Kameda, J
    Koshio, Y
    Minamino, A
    Mitsuda, C
    Miura, M
    Moriyama, S
    Nakahata, M
    Namba, T
    Nambu, R
    Obayashi, Y
    Shiozawa, M
    Suzuki, Y
    Takeuchi, Y
    Taki, K
    Yamada, S
    Ishitsuka, M
    Kajita, T
    Kaneyuki, K
    Nakayama, S
    Okada, A
    Okumura, K
    Saji, C
    Takenaga, Y
    Clark, ST
    Desai, S
    Kearns, E
    Likhoded, S
    Stone, JL
    Sulak, LR
    Wang, W
    Goldhaber, M
    Casper, D
    Cravens, JP
    Gajewski, W
    Kropp, WR
    Liu, DW
    Mine, S
    Smy, MB
    Sobel, HW
    Sterner, CW
    Vagins, MR
    Ganezer, KS
    Hill, J
    Keig, WE
    Jang, JS
    Kim, JY
    PHYSICAL REVIEW D, 2005, 71 (11):
  • [29] Reactor anti-neutrino oscillations and gadolinium loaded super-kamiokande detector
    Choubey, S
    Petcov, ST
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2005, 143 : 489 - 489
  • [30] First measurement of radioactive isotope production through cosmic-ray muon spallation in Super-Kamiokande IV
    Zhang, Y.
    Abe, K.
    Haga, Y.
    Hayato, Y.
    Ikeda, M.
    Iyogi, K.
    Kameda, J.
    Kishimoto, Y.
    Miura, M.
    Moriyama, S.
    Nakahata, M.
    Nakajima, T.
    Nakano, Y.
    Nakayama, S.
    Orii, A.
    Sekiya, H.
    Shiozawa, M.
    Takeda, A.
    Tanaka, H.
    Tomura, T.
    Wendell, R. A.
    Irvine, T.
    Kajita, T.
    Kametani, I.
    Kaneyuki, K.
    Nishimura, Y.
    Richard, E.
    Okumura, K.
    Labarga, L.
    Fernandez, P.
    Gustafson, J.
    Kachulis, C.
    Kearns, E.
    Raaf, J. L.
    Stone, J. L.
    Sulak, L. R.
    Berkman, S.
    Nantais, C. M.
    Tanaka, H. A.
    Tobayama, S.
    Goldhaber, M.
    Carminati, G.
    Griskevich, N. J.
    Kropp, W. R.
    Mine, S.
    Renshaw, A.
    Smy, M. B.
    Sobel, H. W.
    Takhistov, V.
    Weatherly, P.
    PHYSICAL REVIEW D, 2016, 93 (01)