Composite Nanofibers as Novel Sorbents for On-Line and Off-Line Solid-Phase Extraction in Chromatographic System: A Comparison for Detection of Free Biogenic Monoamines and Their Metabolites in Plasma

被引:0
|
作者
Chen, Liqin [1 ,2 ]
Bi, Yueling [3 ]
Xu, Tong [1 ]
Li, Xiaohuan [1 ]
Fang, Zhongze [1 ,2 ]
机构
[1] Tianjin Med Univ, Sch Publ Hlth, Dept Toxicol & Sanit Chem, Tianjin 300070, Peoples R China
[2] Tianjin Key Lab Environm Nutr & Publ Hlth, Tianjin 300070, Peoples R China
[3] Tianjin Xiqing Hosp, Dept Pharm, Tianjin 300380, Peoples R China
来源
MOLECULES | 2022年 / 27卷 / 20期
基金
中国国家自然科学基金;
关键词
on-line packed-fiber solid-phase extraction; nanofibers; HPLC; biogenic monoamines; plasma; ELECTROSPUN POLYMER NANOFIBERS; LIQUID-CHROMATOGRAPHY; CROWN-ETHER; CATECHOLAMINES; PERFORMANCE; HPLC; SPE;
D O I
10.3390/molecules27206971
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Two different pretreatment approaches have been used for the enrichment and separation of biogenic monoamines and metabolites in plasma for high performance liquid chromatography (HPLC) determination. The first approach, based on on-line packed-fiber solid-phase extraction (PFSPE) coupled with HPLC, allows for the simultaneous detection of epinephrine (E), norepinephrine (NE), dopamine (DA), 3-methoxyl epinephrine (MN), norepinephrine (NMN), 3-methoxytyramine (3-MT), and 5-hydroxytryptamin (5-HT). Using this developed on-line PFSPE-HPLC method, the limit of detections (LODs) of the seven analytes ranged from 1 ng/mL (NMN and MN) to 2 ng/mL (NE, E, DA, 3-MT and 5-HT). The reportable ranges were 5-300 ng/mL for NE and DA, 5-100 ng/mL for E, and 5-200 ng/mL for NMN, MN, 3-MT and 5-HT. The off-line PFSPE-HPLC was employed in the second approach and could provide simultaneous detection of NE, E, DA, NMN, and MN. The linearity was verified in the range of 0.5-20 ng/mL (NE, E, and DA) and 20-250 ng/mL (NMN and MN). The LODs of the five analytes ranged from 0.2 ng/mL (NE, E, and DA) to 5 ng/mL (NMN and MN). This study verified the possibility of using nanofibers as an adsorbent in an on-line PFSPE-HPLC system for the determination of biogenic monoamines and their metabolites in human plasma. Compared with the off-line PFSPE approach, the on-line PFSPE method deserves attention mainly due to its greener character, derived from the automation of the process and high-throughput with less operators' handling.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] On-line solid-phase extraction and HPLC determination of polycyclic aromatic hydrocarbons in water using fluorocarbon polymer sorbents
    Oliferova, L
    Statkus, M
    Tsysin, G
    Shpigun, O
    Zolotov, Y
    ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 35 - 40
  • [42] Quantitation of promethazine and metabolites in urine samples using on-line solid-phase extraction and column-switching
    Song, Q
    Putcha, L
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 763 (1-2): : 9 - 20
  • [43] HIGHLY SPECIFIC OFF-LINE SOLID-PHASE EXTRACTION OF BASIC LIPOPHILIC DRUGS FROM BLOOD-PLASMA WITH AUTOMATED ONLINE ELUTION
    KUPFERSCHMIDT, R
    SCHMID, R
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1987, 25 (09): : 616 - 617
  • [44] Fabrication of a cycloalkyl-monolith for on-line solid-phase extraction and determination of four polyphyllins in plasma
    Peng, Shan
    Bai, Ligai
    Wang, Laisen
    Sun, Fanrong
    Liu, Haiyan
    Yan, Hongyuan
    ANALYTICAL BIOCHEMISTRY, 2020, 591
  • [45] Automated on-line solid-phase extraction gas chromatography with nitrogen-phosphorus detection: Determination of benzodiazepines in human plasma
    Louter, AJH
    Bosma, E
    Schipperen, JCA
    Vreuls, JJ
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01): : 35 - 43
  • [46] Determination of phenols in water by on-line solid-phase disk extraction and liquid chromatography with electrochemical detection
    Jauregui, O
    Galceran, MT
    ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) : 191 - 199
  • [47] Determination of salbutamol using on-line solid-phase extraction and sequential injection analysis. Comparison of chemiluminescence and fluorescence detection
    Jitka Huclová
    Dalibor Šatínský
    Hana Sklenářová
    Rolf Karlíček
    Analytical and Bioanalytical Chemistry, 2003, 376 : 448 - 454
  • [48] Determination of salbutamol using on-line solid-phase extraction and sequential injection analysis.: Comparison of chemiluminescence and fluorescence detection
    Huclová, J
    Satínsky, D
    Sklenárová, H
    Karlícek, R
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (04) : 448 - 454
  • [49] Evaluation of new polymeric sorbents with high specific surface areas using an on-line solid-phase extraction liquid chromatographic system for the trace-level determination of polar pesticides
    Guenu, S
    Hennion, MC
    JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (01) : 15 - 24
  • [50] Fully automated solid-phase extraction cleanup and on-line liquid chromatographic determination of benzimidazole fungicides in fruit and vegetables
    Hiemstra, M
    Joosten, JA
    DeKok, A
    JOURNAL OF AOAC INTERNATIONAL, 1995, 78 (05) : 1267 - 1274