Comparison of femoral graft bending angle and tunnel length between transtibial technique and transportal technique in anterior cruciate ligament reconstruction

被引:59
|
作者
Wang, Joon Ho [2 ]
Kim, Jae Gyoon [1 ]
Lee, Do Kyung [2 ]
Lim, Hong Chul [1 ]
Ahn, Jin Hwan [3 ]
机构
[1] Korea Univ, Guro Hosp, Coll Med, Dept Orthoped Surg, Seoul 152703, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Orthopaed Surg, Seoul, South Korea
[3] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Orthoped Surg, Seoul, South Korea
关键词
Knee; Anterior cruciate ligament; Transportal; Transtibial; 3D-CT; OsiriX; KNEE FLEXION ANGLE; HAMSTRING TENDONS; FOLLOW-UP; BUNDLE; PLACEMENT; POSITION; AUGMENTATION; ARTHROSCOPY; STABILITY; AUTOGRAFT;
D O I
10.1007/s00167-011-1781-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To investigate which technique would reduce bending stress at the femoral tunnel aperture and make short tunnel length after ACL reconstruction by comparing the femoral graft bending angle and tunnel length between the single-bundle (SB) transtibial (TT) and double-bundle (DB) transportal (TP) technique using three-dimensional-computed tomography using OsiriX(A (R)) imaging software. Forty-nine patients underwent an ACL reconstruction using a SB TT (Group I, 20 patients) and DB TP (Group II, 29 patients) technique. Femoral graft bending angle and femoral tunnel length were measured by CT image using OsiriX(A (R)) imaging software. Groups I and II were compared, and statistical analysis was performed using SPSS software. The mean anteromedial (AM) and posterolateral (PL) femoral graft bending angle of group II (111.5 +/- A 8.8A degrees and 118.9 +/- A 9.8A degrees, respectively) was significantly more acute than that of group I (125.3 +/- A 11.1A degrees) (P < 0.001, P = 0.04). The mean femoral tunnel length of group I was significantly longer than that of group II (P = 0.001). The femoral graft bending angle and the femoral tunnel length of the TP technique performed in the maximally flexed knee position was more acute and shorter than those of the TT technique after ACL reconstruction. This might increase the bending stress at the femoral tunnel aperture and shorter graft length in the tunnel after an ACL reconstruction using TP technique compared to the TT technique. III.
引用
收藏
页码:1584 / 1593
页数:10
相关论文
共 50 条
  • [31] The influence of femoral tunnel length on graft rupture after anterior cruciate ligament reconstruction
    Betoni Guglielmetti, Luiz Gabriel
    Shimba, Leandro Girardi
    do Santos, Leonardo Cantarelli
    Severino, Fabricio Roberto
    Severino, Nilson Roberto
    de Moraes Barros Fucs, Patricia Maria
    Leite Cury, Ricardo de Paula
    [J]. JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2017, 18 (03) : 243 - 250
  • [32] The influence of femoral tunnel length on graft rupture after anterior cruciate ligament reconstruction
    Luiz Gabriel Betoni Guglielmetti
    Leandro Girardi Shimba
    Leonardo Cantarelli do Santos
    Fabrício Roberto Severino
    Nilson Roberto Severino
    Patrícia Maria de Moraes Barros Fucs
    Ricardo de Paula Leite Cury
    [J]. Journal of Orthopaedics and Traumatology, 2017, 18 : 243 - 250
  • [33] Calculation of Graft Bending Angle in Anterior Cruciate Ligament Reconstruction
    Nagamune, Kouki
    Nishizawa, Yuichiro
    Nishimto, Koji
    Hoshino, Yuichi
    Kubo, Seiji
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    [J]. PROCEEDINGS 2012 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2012, : 237 - 241
  • [34] Anterior cruciate ligament reconstruction: a new cortical suspension device for femoral fixation with transtibial and transportal techniques
    Betoni Guglielmetti, Luiz Gabriel
    Leite Cury, Ricardo de Paula
    de Oliveira, Victor Marques
    Arbix de Camargo, Osmar Pedro
    Severino, Nilson Roberto
    de Moraes Barros Fucs, Patricia Maria
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9 : 110
  • [35] Anterior cruciate ligament reconstruction: a new cortical suspension device for femoral fixation with transtibial and transportal techniques
    Luiz Gabriel Betoni Guglielmetti
    Ricardo de Paula Leite Cury
    Victor Marques de Oliveira
    Osmar Pedro Arbix de Camargo
    Nilson Roberto Severino
    Patrícia Maria de Moraes Barros Fucs
    [J]. Journal of Orthopaedic Surgery and Research, 9
  • [36] Optimal tibial tunnel angulation for anatomical anterior cruciate ligament reconstruction using transtibial technique
    Zhang, Ling
    Xu, Junjie
    Wang, Cong
    Luo, Ye
    Tsai, Tsung-Yuan
    Zhao, Jinzhong
    Wang, Shaobai
    [J]. MEDICAL ENGINEERING & PHYSICS, 2024, 129
  • [37] Tibial graft fixation in anterior cruciate ligament reconstruction: multiple tibial tunnel technique (collateral tunnel technique)
    Altunkilic, T.
    Ari, B.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2022, 26 (22) : 8289 - 8302
  • [38] Influence of Graft Bending Angle on Graft Maturation, the Femoral Tunnel, and Functional Outcomes by 12 Months After Anterior Cruciate Ligament Reconstruction
    Li, Hong
    Liu, Shaohua
    Sun, Yaying
    Li, Hongyun
    Chen, Shiyi
    Chen, Jiwu
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (11)
  • [39] No clinical differences between anteromedial portal and transtibial technique for femoral tunnel positioning in anterior cruciate ligament reconstruction: a prospective randomized, controlled trial
    Peter MacDonald
    Chris Kim
    Sheila McRae
    Jeff Leiter
    Ryan Khan
    Daniel Whelan
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1335 - 1342
  • [40] The Relationship Between Lateral Femoral Anatomic Structures and the Femoral Tunnel Outlet in Anterior Cruciate Ligament Reconstruction Using the Transportal Technique: A 3-Dimensional Simulation Analysis
    Chung, Kwangho
    Choi, Chong Hyuk
    Kim, Sung-Hwan
    Kim, Sung-Jae
    Do, Woosung
    Jung, Min
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (09)