Femoral impaction bone allografting has been developed as a means of restoring bone stock in revision total hip replacement. We report the results of 75 consecutive patients (75 hips) with a mean age of 68 years (35 to 87) who underwent impaction grafting using the Exeter collarless, polished, tapered femoral stem between 1992 and 1998. The mean follow-up period was 10.5 years (6.3 to 14.1). The median pre-operative bone defect score was 3 (interquartile range (IQR) 2 to 3) using the Endo-Klinik classification. The median subsidence at one year post-operatively was 2 mm (IQR 1 to 3). At the final review the median Harris hip score was 80.6 (IQR 67.6 to 88.9) and the median subsidence 2 mm (IQR 1 to 4). Incorporation of the allograft into trabecular bone and secondary remodelling were noted radiologically at the final follow-up in 87% (393 of 452 zones) and 40% (181 of 452 zones), respectively. Subsidence of the Exeter stem correlated with the pre-operative Endo-Klinik bone loss score (p = 0.037). The degree of subsidence at one year had a strong association with long-term subsidence (p < 0.001). There was a significant correlation between previous revision surgery and a poor Harris Hip score (p = 0.028), and those who had undergone previous revision surgery for infection had a higher risk of complications (p = 0.048). Survivorship at 10.5 years with any further femoral operation as the end-point was 92% (95% confidence interval 82 to 97).
引用
收藏
页码:1000 / 1004
页数:5
相关论文
共 50 条
  • [21] Fretting corrosion of fully cemented polished collarless tapered stems: The influence of PMMA bone cement
    Bryant, M.
    Farrar, R.
    Brummitt, K.
    Freeman, R.
    Neville, A.
    WEAR, 2013, 301 (1-2) : 290 - 299
  • [22] A Multi-factor Analysis of Revision in Total Hip Replacement Using the Collarless-Polished-Tapered Stems with Different Cups
    Hong, Yu
    Johnston, Linda
    Wang, Weijie
    ORTHOPAEDIC SURGERY, 2023, 15 (07) : 1870 - 1883
  • [23] Influence of stem geometry on the stability of polished tapered cemented femoral stems
    Glyn-Jones, S
    Gill, HS
    Beard, DJ
    McLardy-Smith, P
    Murray, DW
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (07): : 921 - 927
  • [24] Cemented hemiarthroplasty for femoral neck fracture patients: collarless, polished tapered stem (CPT) versus anatomic matte stem (Lubinus SP2)
    Rajzan Joanroy
    Jesper Stork-Hansen
    Lars Rotwitt
    Bjarke Viberg
    European Journal of Orthopaedic Surgery & Traumatology, 2021, 31 : 855 - 860
  • [25] Cemented hemiarthroplasty for femoral neck fracture patients: collarless, polished tapered stem (CPT) versus anatomic matte stem (Lubinus SP2)
    Joanroy, Rajzan
    Stork-Hansen, Jesper
    Rotwitt, Lars
    Viberg, Bjarke
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (05): : 855 - 860
  • [26] Stem fracture of a collarless, polished, double-taper cemented femoral prosthesis : A case report
    Raj, Dipak
    Coupe, Benjamin D.
    Keene, Graham S.
    ACTA ORTHOPAEDICA BELGICA, 2008, 74 (05): : 697 - 699
  • [27] Collarless polished tapered impaction grafting of the femur during revision total hip arthroplasty - Pitfalls of the surgical technique and follow-up in 31 cases
    Knight, JL
    Helming, C
    JOURNAL OF ARTHROPLASTY, 2000, 15 (02): : 159 - 165
  • [28] A unique peri-prosthetic fracture pattern in well fixed femoral stems with polished, tapered, collarless design of total hip replacement
    Grammatopoulos, George
    Pandit, Hemant
    Kambouroglou, Gregoris
    Deakin, Mark
    Gundle, Roger
    McLardy-Smith, Peter
    Taylor, Adrian
    Murray, David
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1271 - 1276
  • [29] Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement
    Rajeev, Aysha
    Mohamed, Abdalla
    Shaikh, Mazharuddin
    Banaszkiewicz, Paul
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2016, 22 : 66 - 69
  • [30] Impaction bone grafting and cemented stem revision in periprosthetic hip fractures: a novel surgical technique
    Dearden, Paul M.
    Bobak, Peter P.
    Giannoudis, Peter V.
    HIP INTERNATIONAL, 2014, 24 (02) : 210 - 212