Examination of the Effects of Vardenafil on Esophageal Function Using Multichannel Intraluminal Impedance and Manometry

被引:2
|
作者
Lee, Tae Hee [1 ]
Lee, Joon Seong [1 ]
Hong, Su Jin [2 ]
Jeon, Seong Ran [1 ]
Kim, Wan Jung [3 ]
Kim, Hyun Gun [1 ]
Cho, Joo Young [1 ]
Kim, Jin-Oh [1 ]
机构
[1] Soonchunhyang Univ Seoul Hosp, Ctr Digest Dis, Inst Digest Res, Seoul, South Korea
[2] Soonchunhyang Univ, Coll Med, Dept Internal Med, Puchon, Gyeonggi Do, South Korea
[3] Soonchunhyang Univ Hosp, Dept Internal Med, Gumi, Gyeongsangbuk D, South Korea
关键词
Manometry; Phosphodiesterase; 5; inhibitor; Vardenafil; GASTROESOPHAGEAL-REFLUX; MOTOR FUNCTION; NITRIC-OXIDE; SILDENAFIL; MOTILITY; INHIBITORS; HUMANS;
D O I
10.5056/jnm.2012.18.4.399
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims To evaluate the effects of the phosphodiesterase type 5 (PDE5) inhibitor vardenafil on esophageal function, including bolus transit, using multichannel intraluminal impedance and esophageal manometry (MII-EM). Methods Sixteen healthy volunteers (15 men) underwent an MII-EM study including 10 liquid swallows and 10 viscous swallows in a seated position after fasting. Then, each subject was asked to ingest 50 mL distilled water or 10 mg vardenafil dissolved in 50 mL water, in a double-blind manner. After 25 minutes, the MII-EM study was repeated. Results Eight men received vardenafil and eight subjects received water. Resting and residual lower esophageal sphincter pressures differed significantly only in the vardenafil group (from 18 +/- 6.7 to 6.6 +/- 5.3 mmHg, P < 0.001 and from 4.9 +/- 2.6 to 2.1 +/- 3.6 mmHg, P = 0.006, respectively). Mean distal esophageal amplitude decreased significantly only in the vardenafil group (from 86.7 +/- 41.6 to 34.0 +/- 38.0 mmHg, P < 0.05). Complete bolus transits of liquid and viscous meals decreased significantly only after vardenafil ingestion (from 80.2% +/- 13.8% to 49.4% +/- 27.9%, P < 0.05 and from 72.8% +/- 33.6% to 21.5% +/- 29.0%, P = 0.01, respectively). Conclusions Vardenafil decreased esophageal bolus transit in the seated position, despite decreased lower esophageal sphincter pressure.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 50 条
  • [31] High resolution manometry and multichannel intraluminal impedance oesophageal manometry in clinical practice
    Mainie, Inder
    FRONTLINE GASTROENTEROLOGY, 2010, 1 (02) : 112 - 117
  • [32] Esophageal function in normal volunteers and patients with ineffective esophageal motility (IEM) assessed through combined multichannel intraluminal impedance and manometry (MII/EM).
    Vela, MF
    Tutuian, RI
    Baldoo, L
    Gideon, M
    Katz, PO
    Castell, DO
    GASTROENTEROLOGY, 2001, 120 (05) : A632 - A632
  • [33] An audit of combined multichannel intraluminal impedance manometry in the assessment of dysphagia
    Burgess, Nicholas G.
    Wyeth, John W.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2011, 26 : 79 - 82
  • [34] Gatorade is a good substitute for normal saline in multichannel intraluminal impedance and manometry
    Chowdhury, Nazif
    Anwar, Zeba
    Deen, Omer
    Rackett, Richard
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 : S13 - S13
  • [35] Multichannel intraluminal esophageal impedance:: A new frontier in motility
    de la Morena, F.
    Santander Vaquero, C.
    Cantero, J.
    Perez, T.
    Moreno Otero, R.
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2008, 100 (02) : 86 - 89
  • [36] IN SYSTEMIC SCLEROSIS MULTICHANNEL INTRALUMINAL IMPEDANCE SHOWS A BETTER CORRELATION WITH PULMONARY AND SKIN INVOLVEMENT THAN ESOPHAGEAL MANOMETRY
    De Iorio, F.
    Cusumano, C.
    Peraro, L.
    Biasi, D.
    Viaro, T.
    Caramaschi, P.
    Rostello, A.
    Bambara, L. M.
    Vantini, I.
    Benini, L.
    DIGESTIVE AND LIVER DISEASE, 2008, 40 : S19 - S20
  • [37] Does combined multichannel intraluminal esophageal impedance and manometry predict postoperative dysphagia after laparoscopic Nissen fundoplication?
    Montenovo, M.
    Tatum, R. P.
    Figueredo, E.
    Martin, A. Valeria
    Vu, H.
    Quiroga, E.
    Pellegrini, C. A.
    Oelschlager, B. K.
    DISEASES OF THE ESOPHAGUS, 2009, 22 (08): : 656 - 663
  • [38] Does combined multichannel intraluminal esophageal impedance and manometry predict postoperative dysphagia after laparoscopic Nissen fundoplication?
    Montenovo, Martin I.
    Tatum, Roger
    Figueredo, Edgar
    Martin, Valeria
    Vu, Hao
    Quiroga, Elina
    Oelschlager, Brant K.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 : S141 - S141
  • [39] Evaluation of the effects of hyoscine on duodenal motor function using concurrent multiple intraluminal impedance and manometry
    Chaikomin, R
    Wu, KL
    Doran, S
    Smout, A
    Horowitz, M
    Rayner, C
    GASTROENTEROLOGY, 2005, 128 (04) : A672 - A673
  • [40] Is the use of both liquid and viscous test solutions appropriate for esophageal multichannel intraluminal impedance and manometry (mii-Em)?
    Agrawal, A
    Hila, A
    Mainie, I
    Freeman, J
    Tutuian, R
    Castell, DO
    GASTROENTEROLOGY, 2005, 128 (04) : A406 - A406