Modeling DCE-MRI at Low Temporal Resolution: A Case Study on Rheumatoid Arthritis

被引:7
|
作者
Ledsam, Joseph R. [1 ]
Hodgson, Richard [2 ]
Moots, Robert J. [3 ]
Sourbron, Steven P. [1 ]
机构
[1] Univ Leeds, Div Med Phys, Leeds LS2 9JT, W Yorkshire, England
[2] Leeds Musculoskeletal Biomed Res Unit, Leeds, W Yorkshire, England
[3] Univ Liverpool, Liverpool L69 3BX, Merseyside, England
关键词
perfusion; permeability; MRI; dynamic contrast-enhanced; tracer kinetics; two-compartment model; Tofts model; rheumatoid arthritis; CONTRAST-ENHANCED MRI; TRACER KINETICS; PARAMETERS; PERFUSION;
D O I
10.1002/jmri.24061
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo identify the optimal tracer-kinetic modeling strategy for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data acquired at low temporal resolution. Materials and MethodsDCE-MRI was performed on 13 patients with rheumatoid arthritis of the hand before and after anti-tumor necrosis factor alpha (TNF) therapy, using a 3D sequence with a temporal resolution of 13 seconds, imaging for 4 minutes postcontrast injection. Concentration-time curves were extracted from regions of interest (ROIs) in enhancing synovium and fitted to the 3-parameter modified Tofts model (MT) and the 4-parameter two-compartment exchange model (2CXM). To assist the interpretation of the data, the same analysis was applied to simulated data with similar characteristics. ResultsBoth models fitted the data closely, and showed similar therapy effects. The MT plasma volume was significantly lower than with 2CXM, but the differences in permeability and interstitial volume were not significant. 2CXM was less precise than MT, with larger standard deviations relative to the mean in most parameters. The additional perfusion parameter determined with 2CXM did not provide a statistically significant trend due to low precision. ConclusionThe standard MT model is the optimal modeling strategy at low temporal resolution. Advanced models improve the accuracy and generate an additional parameter, but these benefits are offset by low precision. J. Magn. Reson. Imaging 2013;38:1554-1563. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1554 / 1563
页数:10
相关论文
共 50 条
  • [1] High spatial and temporal resolution breast DCE-MRI: A feasibility study
    Roy, N.
    Oh, K. Y.
    Kettler, M. D.
    Tudorica, L. A.
    Huang, W.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (27)
  • [2] Temporal Huber Regularization for DCE-MRI
    Matti Hanhela
    Mikko Kettunen
    Olli Gröhn
    Marko Vauhkonen
    Ville Kolehmainen
    [J]. Journal of Mathematical Imaging and Vision, 2020, 62 : 1334 - 1346
  • [3] Temporal Huber Regularization for DCE-MRI
    Hanhela, Matti
    Kettunen, Mikko
    Gröhn, Olli
    Vauhkonen, Marko
    Kolehmainen, Ville
    [J]. Hanhela, Matti (mattihan@uef.fi), 1600, Springer (62): : 1334 - 1346
  • [4] Temporal Huber Regularization for DCE-MRI
    Hanhela, Matti
    Kettunen, Mikko
    Grohn, Olli
    Vauhkonen, Marko
    Kolehmainen, Ville
    [J]. JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2020, 62 (09) : 1334 - 1346
  • [5] The use of a reference tissue arterial input function with low-temporal-resolution DCE-MRI data
    Heisen, M.
    Fan, X.
    Buurman, J.
    van Riel, N. A. W.
    Karczmar, G. S.
    Romeny, B. M. ter Haar
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16): : 4871 - 4883
  • [6] The Influence of Temporal Resolution in Determining Pharmacokinetic Parameters From DCE-MRI Data
    Heisen, Marieke
    Fan, Xiaobing
    Buurman, Johannes
    van Riel, Natal A. W.
    Karczmar, Gregory S.
    Romeny, Bart M. ter Haar
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) : 811 - 816
  • [7] Feasibility of high temporal resolution breast DCE-MRI using compressed sensing theory
    Wang, Haoyu
    Miao, Yanwei
    Zhou, Kun
    Yu, Yanming
    Bao, Shanglian
    He, Qiang
    Dai, Yongming
    Xuan, Stephanie Y.
    Tarabishy, Bisher
    Ye, Yongquan
    Hu, Jiani
    [J]. MEDICAL PHYSICS, 2010, 37 (09) : 4971 - 4981
  • [8] Blind deconvolution decreases requirements on temporal resolution of DCE-MRI: Application to 2nd generation pharmacokinetic modeling
    Kratochvila, Jiri
    Jir, Radovan
    Bartos, Michal
    Standara, Michal
    Starcuk Jr, Zenon
    Taxt, Torfinn
    [J]. MAGNETIC RESONANCE IMAGING, 2024, 109 : 238 - 248
  • [9] A linear algorithm of the reference region model for DCE-MRI is robust and relaxes requirements for temporal resolution
    Cardenas-Rodriguez, Julio
    Howison, Christine M.
    Pagel, Mark D.
    [J]. MAGNETIC RESONANCE IMAGING, 2013, 31 (04) : 497 - 507
  • [10] Temporal Resolution and SNR Requirements for Accurate DCE-MRI Data Analysis Using the AATH Model
    Kershaw, Lucy E.
    Cheng, Hai-Ling Margaret
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1772 - 1780