Delineation of hippocampal subregions using T1-weighted magnetic resonance images at 3 Tesla

被引:5
|
作者
Rhindress, Kathryn [1 ,2 ,3 ]
Ikuta, Toshikazu [4 ]
Wellington, Robin [3 ]
Malhotra, Anil K. [1 ,2 ,5 ,6 ]
Szeszko, Philip R. [1 ,2 ,5 ,6 ]
机构
[1] Feinstein Inst Med Res, Ctr Psychiat Neurosci, Manhasset, NY USA
[2] North Shore LIJ Hlth Syst, Zucker Hillside Hosp, Div Psychiat Res, Glen Oaks, NY 11004 USA
[3] St Johns Univ, Dept Psychol, Queens, NY USA
[4] Univ Mississippi, Dept Commun Sci & Disorders, Oxford, MS USA
[5] Hofstra North Shore LIJ Sch Med, Dept Psychiat, Hempstead, NY USA
[6] Hofstra North Shore LIJ Sch Med, Dept Mol Med, Hempstead, NY USA
来源
BRAIN STRUCTURE & FUNCTION | 2015年 / 220卷 / 06期
关键词
Magnetic resonance imaging; Hippocampus; Subregion; 3; Tesla; Delineation criteria; HIGH-RESOLUTION MRI; ALZHEIMERS-DISEASE; SUBFIELDS; ANTERIOR; VOLUME; AGE; SEGMENTATION; ATROPHY; 1ST-EPISODE; MEMORY;
D O I
10.1007/s00429-014-0854-1
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Although several novel approaches for hippocampal subregion delineation have been developed, they need to be applied prospectively and may be limited by long scan times, the use of high field (> 3T) imaging systems, and limited reliability metrics. Moreover, the majority of MR imaging data collected to date has employed a T1-weighted acquisition, creating a critical need for an approach that provides reliable hippocampal subregion segmentation using such a contrast. We present a highly reliable approach for the identification of six subregions comprising the hippocampal formation from MR images including the subiculum, dentate gyrus/cornu Ammonis 4 (DG/CA4), entorhinal cortex, fimbria, and anterior and posterior segments of cornu Ammonis 1-3 (CA1-3). MR images were obtained in the coronal plane using a standard 3D spoiled gradient sequence acquired on a GE 3T scanner through the whole head in approximately 10 min. The average ICC for inter-rater reliability across right and left volumetric regions-of-interest was 0.85 (range 0.71-0.98, median 0.86) and the average ICC for intra-rater reliability was 0.92 (range 0.66-0.99, median 0.97). The mean Dice index for inter-rater reliability across right and left hemisphere subregions was 0.75 (range 0.70-0.81, median 0.75) and the mean Dice index for intra-rater reliability was 0.85 (range 0.82-0.90, median 0.85). An investigation of hippocampal asymmetry revealed significantly greater right compared to left hemisphere volumes in the anterior segment of CA1-3 and in the subiculum.
引用
收藏
页码:3259 / 3272
页数:14
相关论文
共 50 条
  • [31] Fast and robust segmentation of head in T1-weighted magnetic resonance volumes
    Hu, Qingmao
    Qian, Guoyu
    Nowinski, Wieslaw L.
    2006 9TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION, VOLS 1- 5, 2006, : 1965 - +
  • [32] On the noise in "augmented T1-weighted steady state magnetic resonance imaging"
    Leupold, Jochen
    Kiselev, Valerij G. G.
    NMR IN BIOMEDICINE, 2023, 36 (05)
  • [33] Quantifying Bone Marrow Adiposity Using T1-weighted Magnetic Resonance Images in Children With Typical Development and in Children With Cerebral Palsy
    Zhang, Chuan
    Miller, Freeman
    Modlesky, Christopher
    JOURNAL OF BONE AND MINERAL RESEARCH, 2018, 33 : 432 - 432
  • [34] Paramagnetic and Superparamagnetic Inorganic Nanoparticles for T1-Weighted Magnetic Resonance Imaging
    Zeng, Leyong
    Wu, Di
    Zou, Ruifen
    Chen, Tianxiang
    Zhang, Jinchao
    Wu, Aiguo
    CURRENT MEDICINAL CHEMISTRY, 2018, 25 (25) : 2970 - 2986
  • [35] Diet and gastrointestinal signal on T1-weighted magnetic resonance imaging of mice
    Kiryu, Shigeru
    Inoue, Yusuke
    Yoshikawa, Kohki
    Shimada, Mono
    Watanabe, Makoto
    Ohtomo, Kuni
    MAGNETIC RESONANCE IMAGING, 2010, 28 (02) : 273 - 280
  • [36] Visualisation of the fetal bowel on T1-weighted magnetic resonance imaging scans
    Hyde, G.
    Fry, A.
    Whitby, E.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2019, 126 : 84 - 84
  • [37] Are TrueFISP images T2/T1-weighted?
    Huang, TY
    Huang, IJ
    Chen, CY
    Scheffler, K
    Chung, HW
    Cheng, HC
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 684 - 688
  • [38] Hyperintense basal ganglia on T1-weighted magnetic resonance images following postoperative parenteral nutrition in a pancreatoduodenectomized patient
    Iwase, K
    Kondoh, H
    Higaki, J
    Tanaka, Y
    Yoshikawa, M
    Hori, S
    Osuga, K
    Kamiike, W
    DIGESTIVE SURGERY, 2000, 17 (02) : 190 - 193
  • [39] Registration of in vivo magnetic resonance T1-weighted brain images to triphenyltetrazolium chloride stained sections in small animals
    Li, Guokuan
    Nikolova, Simona
    Bartha, Robert
    JOURNAL OF NEUROSCIENCE METHODS, 2006, 156 (1-2) : 368 - 375
  • [40] Transient central diabetes insipidus in pregnancy with a peculiar change in signal intensity on T1-weighted magnetic resonance images
    Yamamoto, T
    Ishii, T
    Yoshioka, K
    Yamagami, K
    Yamakita, T
    Miyamoto, M
    Hosoi, M
    Sato, T
    Tanaka, S
    Fujii, S
    INTERNAL MEDICINE, 2003, 42 (06) : 513 - 516