The gVERSE RF Pulse: An Optimal Approach to MRI Pulse Design

被引:0
|
作者
Anand, Christopher K. [1 ]
Stoyan, Stephen J. [2 ]
Terlaky, Tamas [1 ]
机构
[1] McMaster Univ, Hamilton, ON, Canada
[2] Univ Toronto, Toronto, ON, Canada
关键词
D O I
10.1007/978-3-540-79409-7_3
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
A Variable Rate Selective Excitation (VERSE) is a type of Radio Frequency (RF) pulse that reduces the Specific Absorption Rate (SAR) of molecules in a specimen. As high levels of SAR lead to increased patient temperatures during Magnetic Resonance Imaging (MRI) procedures, we develop a selective VERSE pulse that is designed to minimize SAR while preserving its duration and slice profile; called the generalized VERSE (gVERSE). After the formulation of a rigorous mathematical model, the nonlinear gVERSE optimization problem is solved via an optimal control approach. Using the state of the art Sparse Optimal Control Software (SOCS), two separate variations of SAR reducing gVERSE pulses were generated. The Magnetic Resonance (MR) signals produced by numerical simulations were then tested and analyzed by an MRI simulator. Computational experiments involved with the gVERSE model provided constant RF pulse levels and had encouraging results with respect to MR signals. The testing results produced by the gVERSE pulse illustrate the potential advanced optimization techniques have in designing RF sequences.
引用
收藏
页码:25 / +
页数:3
相关论文
共 50 条
  • [11] CORRECTING FOR RF INHOMOGENEITIES IN MULTIECHO PULSE SEQUENCE MRI DOSIMETRY
    DUZENLI, C
    ROBINSON, D
    MEDICAL PHYSICS, 1995, 22 (10) : 1645 - 1650
  • [12] MRI RF Pulse Spectral Regrowth Contributions by PIN Diodes
    Caverly, Robert H.
    2017 IEEE RADIO AND WIRELESS SYMPOSIUM (RWS), 2017, : 194 - 196
  • [13] HIGH FIELD RF SUPERCONDUCTIVITY: TO PULSE OR NOT TO PULSE?
    Campisi, Isidoro Enrico
    IEEE Transactions on Magnetics, 1984, MAG-21 (02)
  • [14] Multiband RF pulse design for realistic gradient performance
    Seada, Samy Abo
    Price, Anthony N.
    Schneider, Torben
    Hajnal, Joseph V.
    Malik, Shaihan J.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 362 - 376
  • [15] RF PULSE DESIGN USING THE INVERSE SCATTERING TRANSFORM
    BUONOCORE, MH
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) : 470 - 477
  • [16] Optimized amplitude modulated multiband RF pulse design
    Seada, Samy Abo
    Price, Anthony N.
    Hajnal, Joseph V.
    Malik, Shaihan J.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2185 - 2193
  • [17] OPTIMAL THRUST DESIGN OF A MISSILE WITH A PULSE MOTOR
    IMADO, F
    KURODA, T
    MIWA, S
    AIAA GUIDANCE, NAVIGATION AND CONTROL CONFERENCE, PTS 1 AND 2: A COLLECTION OF TECHNICAL PAPERS, 1989, : 463 - 469
  • [18] Optimal Design of UWB Pulse Based on IDFT
    Li Bin
    Zhou Zheng
    Zou Weixia
    2009 5TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS, NETWORKING AND MOBILE COMPUTING, VOLS 1-8, 2009, : 1726 - 1729
  • [19] AN RF PULSE MULTIPLIER
    VENGER, AZ
    TERESHCHENKO, ND
    KORZHENKO, VI
    YAKIMENKO, AM
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1979, 33-4 (07) : 111 - 112
  • [20] Optimal Control Approach with Block Pulse Functions
    Aousgi, Ines Sansa
    Elloumi, Salwa
    Braiek, Naceur Benhadj
    14TH INTERNATIONAL CONFERENCE ON SCIENCES AND TECHNIQUES OF AUTOMATIC CONTROL & COMPUTER ENGINEERING STA 2013, 2013, : 331 - 336