Parallel conductance estimation by hypertonic dilution method with conductance catheter: Effects of the bolus concentration and temperature

被引:8
|
作者
Herrera, MC
Olivera, JM
Valentinuzzi, ME
机构
[1] Univ Nacl Tucuman, Fac Ciencias Exatas & Tecnol, Dept Bioingn, RA-4000 San Miguel De Tucuman, Tucuman, Argentina
[2] CONICET, INSIBIO, RA-4000 San Miguel De Tucuman, Tucuman, Argentina
关键词
conductance catheter; impedance volumetry; left ventricular volume; parallel volume; saline indicator method;
D O I
10.1109/10.771192
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The conductance catheter has gained momentum since its introduction in cardiovascular dynamics back in 1980, However, measuring errors are still blurring its clinical acceptance. The main objective here was to study the effects of the injected saline concentration and temperature on the evaluation of the parallel conductance, G(p), and thus, on the correction volume V-p. That conductance, G(p), and its associated volume, V-p, were computed using 167 saline dilution curves obtained with boluses at different concentrations and temperatures, injected in seven anesthetized closed-chest dogs. The excursion of the total conductance relative to the steady-state value during a saline maneuver showed good correlation with the injected concentration at both studied temperatures. The reference parallel volume (one reference per dog) was defined as the average value obtained with three successive maneuvers, at 6-M concentration and at body temperature; therefore, the method acted as its own reference. The variation of V-p relative to the reference value nas clearly dependent on the injected concentration and on its temperature; dispersion was greater at 22 degrees C than at 40 degrees C, The variability would recognize also other causes, such as uncertainty of the extrapolation procedure and the thoracic redistribution of electrical field lines. As conclusion, it is recommended to characterize each maneuver by its concentration and temperature. Body temperature and 6-M concentration appear as the most recommendable combination for the injectate in most animals. Finally, these results intend to characterize the V-p estimation procedure in order to minimize errors. The variability of V-p, in different experimental conditions, demonstrated that both concentration and temperature are additional parameters that mag modify the G(p) estimate.
引用
收藏
页码:830 / 837
页数:8
相关论文
共 50 条
  • [21] Accurate photosynthetic parameter estimation at low stomatal conductance: effects of cuticular conductance and instrumental noise
    Hussain, Syed Bilal
    Stinziano, Joseph
    Pierre, Myrtho O.
    Vincent, Christopher
    PHOTOSYNTHESIS RESEARCH, 2024, 160 (2-3) : 111 - 124
  • [22] SIMULTANEOUS CONDUCTANCE CATHETER AND RADIONUCLIDE ANGIOGRAPHIC LEFT-VENTRICULAR VOLUMES IN DOGS - PARALLEL CONDUCTANCE IS INDEPENDENT OF LEFT-VENTRICULAR VOLUME
    SZWARC, RS
    MICKLEBOROUGH, LL
    MIZUNO, SI
    MOHAMED, S
    WILSON, GJ
    LIU, P
    CIRCULATION, 1993, 88 (04) : 57 - 57
  • [23] LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE
    BOLTWOOD, CM
    APPLEYARD, RF
    GLANTZ, SA
    CIRCULATION, 1989, 80 (05) : 1360 - 1377
  • [24] Mouse Left Ventricular Volume Estimation by Use of the Conductance Catheter Measurement System
    Wei, Chia-Ling
    Shih, Ming-Hsien
    IEEE CIRCUITS AND SYSTEMS INTERNATIONAL CONFERENCE ON TESTING AND DIAGNOSIS, 2009, : 537 - 540
  • [25] ESTIMATION OF THE THERMAL CONTACT CONDUCTANCE FROM UNSTEADY TEMPERATURE MEASUREMENTS
    Kvapil, Jiri
    Pohanka, Michal
    Horsky, Jaroslav
    MATERIALI IN TEHNOLOGIJE, 2015, 49 (02): : 219 - 222
  • [26] Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications
    Herrera, MC
    Olivera, JM
    Valentinuzzi, ME
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (02) : 169 - 174
  • [27] Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications
    M. C. Herrera
    J. M. Olivera
    M. E. Valentinuzzi
    Medical & Biological Engineering & Computing, 1999, 37 : 169 - 174
  • [29] SPECIFIC CONDUCTANCE METHOD FOR INSITU ESTIMATION OF TOTAL DISSOLVED SOLIDS
    SINGH, T
    KALRA, YP
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1975, 67 (02): : 99 - 100
  • [30] PRESSURE AND TEMPERATURE EFFECTS ON THE EXCESS DEUTERON AND PROTON CONDUCTANCE
    TADA, Y
    UENO, M
    TSUCHIHASHI, N
    SHIMIZU, K
    JOURNAL OF SOLUTION CHEMISTRY, 1992, 21 (09) : 971 - 985