Transfer of transient conditions from prototype to closed-loop model test rig

被引:0
|
作者
Junginger, J. [1 ]
Riedelbauch, S. [1 ]
Kirschner, O. [1 ]
机构
[1] Univ Stuttgart, Inst Fluid Mech & Hydraul Machinery, Pfaffenwaldring 10, D-70569 Stuttgart, Germany
关键词
D O I
10.1088/1755-1315/240/8/082010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes a method for determining the sequence of transient model test experiments in a closed loop test-rig, using previous 1D-simulations. A real power plant with reversible pump turbine in the Austrian Alps serves as baseline. A fast transition with load rejection and guide vane closing has been simulated, as it is state of the art. Furthermore, it was assumed that this power plant also has a full size frequency converter for fast transition from pump mode to turbine mode and vice versa applying linear speed variation. These simulation results were transferred to the scaled model size via similarity laws. Of particular importance is the choice of model to prototype speed ratio whose influence has been studied more closely. Subsequently, the transient processes are simulated in a closed loop test-rig. The simulations are controlled by a temporal power variation of the service pump. An iteration loop with optimizer has adapted the power in order to achieve similar conditions as in the prototype simulation. The findings of the pump behavior can then be used for the transient model test experiments.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Informative Conditions for Identification of MISO ARMAX Model in Closed-loop Systems
    Yan, Wengang
    Zhu, Yucai
    IFAC PAPERSONLINE, 2018, 51 (15): : 455 - 460
  • [22] New rig control system provides closed-loop drilling automation
    Rach, Nina M.
    OIL & GAS JOURNAL, 2007, 105 (27) : 39 - +
  • [23] TRANSIENT CLOSED-LOOP HEATING FOR LOCALIZED MEMS BONDING
    Teal, Daniel
    Pister, Kristofer S. J.
    2022 IEEE 35TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS CONFERENCE (MEMS), 2022, : 569 - 572
  • [24] Transient response of closed-loop MHD experimental facility
    Takana, Hidemasa
    Okuno, Yoshihiro
    Yamasaki, Hiroyuki
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 2007, 158 (01): : 46 - 52
  • [25] A closed-loop logistics model for remanufacturing
    Jayaraman, V
    Guide, VDR
    Srivastava, R
    JOURNAL OF THE OPERATIONAL RESEARCH SOCIETY, 1999, 50 (05) : 497 - 508
  • [26] Transient response of closed-loop MHD experimental facility
    Takana, Hidemasa
    Okuno, Yoshihiro
    Yamasaki, Hiroyuki
    ELECTRICAL ENGINEERING IN JAPAN, 2007, 158 (01) : 46 - 52
  • [27] WEAR IN SLURRY PIPELINES: EXPERIMENTS WITH 38mm DIAMETER SPECIMENS IN A CLOSED-LOOP TEST RIG.
    James, J.G.
    Broad, B.A.
    TRRL Supplementary Report (Transport and Road Research Laboratory, Great Britain), 1983,
  • [28] Closed-loop minimal model analysis of the cardiovascular response to transient arousal from sleep in healthy humans
    Blasi, A
    Jo, J
    Valladares, E
    Juarez, R
    Baydur, A
    Khoo, MCK
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3893 - 3896
  • [29] TEST RIG WITH CLOSED POWER LOOP FOR REDUCTION GEAR TESTING
    KUDINOV, VD
    RUSSIAN ENGINEERING JOURNAL, 1974, 54 (07): : 47 - 50
  • [30] ONLINE PID CONTROLLER TUNING FROM A SINGLE, CLOSED-LOOP TEST
    LEE, JT
    AICHE JOURNAL, 1989, 35 (02) : 329 - 331