Transfer of transient conditions from prototype to closed-loop model test rig

被引:0
|
作者
Junginger, J. [1 ]
Riedelbauch, S. [1 ]
Kirschner, O. [1 ]
机构
[1] Univ Stuttgart, Inst Fluid Mech & Hydraul Machinery, Pfaffenwaldring 10, D-70569 Stuttgart, Germany
关键词
D O I
10.1088/1755-1315/240/8/082010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes a method for determining the sequence of transient model test experiments in a closed loop test-rig, using previous 1D-simulations. A real power plant with reversible pump turbine in the Austrian Alps serves as baseline. A fast transition with load rejection and guide vane closing has been simulated, as it is state of the art. Furthermore, it was assumed that this power plant also has a full size frequency converter for fast transition from pump mode to turbine mode and vice versa applying linear speed variation. These simulation results were transferred to the scaled model size via similarity laws. Of particular importance is the choice of model to prototype speed ratio whose influence has been studied more closely. Subsequently, the transient processes are simulated in a closed loop test-rig. The simulations are controlled by a temporal power variation of the service pump. An iteration loop with optimizer has adapted the power in order to achieve similar conditions as in the prototype simulation. The findings of the pump behavior can then be used for the transient model test experiments.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Method to transfer transient prototype conditions to closed-loop model test rig
    Junginger J.
    Kirschner O.
    Riedelbauch S.
    International Journal of Fluid Machinery and Systems, 2020, 13 (01): : 1 - 11
  • [2] The development of the closed-loop control system for the Mechanical suspensions test rig
    Liu, Yan
    ENGINEERING SOLUTIONS FOR MANUFACTURING PROCESSES, PTS 1-3, 2013, 655-657 : 1361 - 1364
  • [3] Application conditions of the closed-loop transfer function formula
    Fushun Shiyou Xueyuan Xuebao, 4 (60-62, 80):
  • [4] Real Time Closed-loop Test Rig for Decentralized Control of Smart Distribution Networks
    Adhikari, D.
    Wu, J.
    O'Malley, G.
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 709 - 713
  • [5] Closed-loop Identification of a Multivariable Dynamic Knee Rig
    Chevalier, Amelie
    Hernandez, Andres
    Ionescu, Clara M.
    Verstraete, Matthias
    De Keyser, Robin
    IFAC PAPERSONLINE, 2015, 48 (28): : 116 - 121
  • [6] Study on transient heat transfer process of spray cooling with closed-loop
    Zhou N.
    Xu M.
    Feng H.
    Duan F.
    Wang Q.
    Chen H.
    Guo Q.
    Zhou, Nianyong (zhounianyong@cczu.edu.cn), 2020, Materials China (71): : 1018 - 1025
  • [7] NUMERICAL MODEL OF AVIATION GEARBOX TEST RIG IN A CLOSED LOOP CONFIGURATION
    Markowski, Tadeusz
    Noga, Stanislaw
    Rudy, Stanislaw
    AVIATION, 2010, 14 (01) : 3 - 11
  • [8] MODEL PREDICTIVE CONTROL OF A HYDRAULIC ACTUATOR IN TORQUE APPLYING SYSTEM OF A MECHANICALLY CLOSED-LOOP TEST RIG FOR THE HELICOPTER GEARBOX
    Parvaresh, Aida
    Mardani, Mohsen
    AVIATION, 2019, 23 (04) : 143 - 153
  • [9] Closed-loop identification of transfer function model for unstable systems
    Ananth, I
    Chidambaram, M
    JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 1999, 336 (07): : 1055 - 1061
  • [10] Design Closed-Loop Measurement and Control System of Drilling Rig
    Jiao, Yang
    Gao, Ling
    He, Siming
    ADVANCED DESIGN TECHNOLOGY, PTS 1-3, 2011, 308-310 : 2042 - 2046