MR imaging of lung parenchyma at 0.2 T: evaluation of imaging techniques, comparative study with chest radiography and interobserver analysis

被引:14
|
作者
Abolmaali, ND
Schmitt, J
Krauss, S
Bretz, F
Deimling, M
Jacobi, V
Vogl, TJ
机构
[1] Goethe Univ Frankfurt, Inst Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Leibniz Univ Hannover, Dept Bioinformat, D-30419 Hannover, Germany
[3] Siemens Med Solut, D-91052 Erlangen, Germany
关键词
magnetic resonance; low-field-strength imaging; comparative studies; lung; MR; radiography; images; analysis;
D O I
10.1007/s00330-003-2215-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate low-field MR imaging of the lung parenchyma in comparison with postero-anterior (PA) and lateral chest radiographs (CR). One hundred one prospectively randomized patients who had received routine CR were additionally examined with magnetic resonance imaging (MRI) at 0.2 T. Utilized sequences were: constructive interference in steady state (CISS), true fast imaging in steady state precession (True-FISP) and T1-weighted spin-echo (T1SE). Consensus reading of two observers was performed for CR. Three other observers analyzed hardcopies of the MRI examinations for each sequence independently. The individual results for the comparisons between the sequences and CR were calculated using kappa coefficients with their corresponding confidence intervals. Additionally, an interobserver analysis was performed.The proportions of agreement for the three sequences compared with CR were high, with 0.93 for CISS, 0.89 for True-FISP and 0.91 for T1SE. The kappa coefficients and the corresponding confidence intervals were 0.81 [0.68; 0.95] for CISS, 0.72 [0.57; 0.88] for True-FISP and 0.78 [0.65; 0.92] for T1SE. Concerning CISS, differences between MRI and CR were mainly related to advantages resulting from cross-sectional imaging. The smallest 95% lower confidence bound of the three kappa measures for comparing the MR readers with each other was 0.97, indicating a high interobserver agreement. Low-field MRI of the lung parenchyma using the CISS sequence is well comparable with chest radiography and demonstrates slight advantages resulting from the cross-sectional imaging technique.
引用
收藏
页码:703 / 708
页数:6
相关论文
共 50 条
  • [21] EVALUATION OF INTRATHORACIC EXTENT OF LUNG-CANCER BY PLAIN CHEST RADIOGRAPHY, COMPUTED-TOMOGRAPHY, AND MAGNETIC-RESONANCE IMAGING
    BATRA, P
    BROWN, K
    COLLINS, JD
    OVENFORS, CO
    STECKEL, RJ
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (06): : 1456 - 1462
  • [22] PRIMARY LUNG-CANCER STAGING - PROSPECTIVE COMPARATIVE-STUDY OF MR IMAGING WITH CT
    MUSSET, D
    GRENIER, P
    CARETTE, MF
    FRIJA, G
    HAUUY, MP
    DESBLEDS, MT
    GIRARD, P
    BIGOT, JM
    LALLEMAND, D
    RADIOLOGY, 1986, 160 (03) : 607 - 611
  • [23] Renal Perfusion 3-T MR Imaging: A Comparative Study of Arterial Spin Labeling and Dynamic Contrast-enhanced Techniques
    Wu, Wen-Chau
    Su, Mao-Yuan
    Chang, Chin-Cheng
    Tseng, Wen-Yih Isaac
    Liu, Kao-Lang
    RADIOLOGY, 2011, 261 (03) : 845 - 853
  • [24] Sensitivity encoding for diffusion-weighted MR Imaging at 3.0 T: intraindividual comparative study
    Kuhl, CK
    Gieseke, J
    von Falkenhausen, M
    Textor, J
    Gernert, S
    Sonntag, C
    Schild, HH
    RADIOLOGY, 2005, 234 (02) : 517 - 526
  • [25] Comparative study and analysis on techniques for diffusion-weighted magnetic resonance imaging
    Wu, Yuan-Hung
    Tseng, Wen-Yi Issac
    Chang, Chein-I
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3024 - 3026
  • [26] The role of imaging techniques in the diagnosis and treatment of neonatal pneumothorax: A comparative analysis of ultrasound and chest X-ray
    Leng, H.
    Zhang, Y.
    Zhang, L.
    Liu, Y.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2024, 22 (02): : 489 - 494
  • [27] Ex vivo evaluation of ferromagnetic aneurysm clips using a 0.2 T extremity MR imaging system: Safety implications for patients
    Shellock, FG
    Shellock, VJ
    RADIOLOGY, 1997, 205 : 1128 - 1128
  • [28] Imaging techniques and histology in the evaluation of liver fibrosis in hepatosplenic schistosomiasis mansoni in Brazil: a comparative study
    Voieta, Izabela
    de Queiroz, Leonardo C.
    Andrade, Luciene M.
    Silva, Luciana Cristina S.
    Fontes, Vitor F.
    Barbosa, Aryon, Jr.
    Resende, Vivian
    Petroianu, Andy
    Andrade, Zilton
    Antunes, Carlos Mauricio
    Lambertucci, Jose Roberto
    MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2010, 105 (04): : 414 - 421
  • [29] Cardiac magnetic resonance imaging using an open 1.0T MR platform: a comparative study with 1.5T
    Ortrud Kosiek
    Katharina A Strach
    Bernhard Schnackenburg
    Alexander Schmeisser
    Jan Smid
    Friederike Walz
    Jens Ricke
    Frank Fischbach
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [30] Comparative MR imaging study of brain maturation in kittens with T1, T2, and the trace of the diffusion tensor
    Baratti, C
    Barnett, AS
    Pierpaoli, C
    RADIOLOGY, 1999, 210 (01) : 133 - 142