MR imaging of lung parenchyma at 0.2 T: evaluation of imaging techniques, comparative study with chest radiography and interobserver analysis

被引:14
|
作者
Abolmaali, ND
Schmitt, J
Krauss, S
Bretz, F
Deimling, M
Jacobi, V
Vogl, TJ
机构
[1] Goethe Univ Frankfurt, Inst Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Leibniz Univ Hannover, Dept Bioinformat, D-30419 Hannover, Germany
[3] Siemens Med Solut, D-91052 Erlangen, Germany
关键词
magnetic resonance; low-field-strength imaging; comparative studies; lung; MR; radiography; images; analysis;
D O I
10.1007/s00330-003-2215-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate low-field MR imaging of the lung parenchyma in comparison with postero-anterior (PA) and lateral chest radiographs (CR). One hundred one prospectively randomized patients who had received routine CR were additionally examined with magnetic resonance imaging (MRI) at 0.2 T. Utilized sequences were: constructive interference in steady state (CISS), true fast imaging in steady state precession (True-FISP) and T1-weighted spin-echo (T1SE). Consensus reading of two observers was performed for CR. Three other observers analyzed hardcopies of the MRI examinations for each sequence independently. The individual results for the comparisons between the sequences and CR were calculated using kappa coefficients with their corresponding confidence intervals. Additionally, an interobserver analysis was performed.The proportions of agreement for the three sequences compared with CR were high, with 0.93 for CISS, 0.89 for True-FISP and 0.91 for T1SE. The kappa coefficients and the corresponding confidence intervals were 0.81 [0.68; 0.95] for CISS, 0.72 [0.57; 0.88] for True-FISP and 0.78 [0.65; 0.92] for T1SE. Concerning CISS, differences between MRI and CR were mainly related to advantages resulting from cross-sectional imaging. The smallest 95% lower confidence bound of the three kappa measures for comparing the MR readers with each other was 0.97, indicating a high interobserver agreement. Low-field MRI of the lung parenchyma using the CISS sequence is well comparable with chest radiography and demonstrates slight advantages resulting from the cross-sectional imaging technique.
引用
收藏
页码:703 / 708
页数:6
相关论文
共 50 条
  • [1] MR imaging of lung parenchyma at 0.2 T: evaluation of imaging techniques, comparative study with chest radiography and interobserver analysis
    Nasreddin D. Abolmaali
    Jan Schmitt
    Sabine Krauss
    Frank Bretz
    Michael Deimling
    Volkmar Jacobi
    Thomas J. Vogl
    European Radiology, 2004, 14 : 703 - 708
  • [2] Fast low-field MR imaging of lung parenchyma in 58 patients: Results of an interobserver analysis
    Abolmaali, ND
    Schmitt, J
    Krauss, S
    Delmling, M
    Jacobi, V
    Vogl, TJ
    RADIOLOGY, 2001, 221 : 630 - 630
  • [3] Evaluation of the diabetic Charcot foot by MR imaging or plain radiography - an observational study
    Chantelau, E.
    Poll, L. W.
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2006, 114 (08) : 428 - 431
  • [4] Ligaments and tendons of the ankle - Evaluation with low-field (0.2 T) MR imaging
    Rand, T
    Ahn, JM
    Muhle, C
    Garcia, M
    Resnick, D
    ACTA RADIOLOGICA, 1999, 40 (03) : 303 - 308
  • [5] Imaging evaluation of meniscal injury of the knee joint - A comparative MR imaging and arthroscopic study
    Chang, CY
    Wu, HTH
    Huang, TF
    Ma, HL
    Hung, SC
    CLINICAL IMAGING, 2004, 28 (05) : 372 - 376
  • [6] High-field-strength MR imaging of the liver at 3.0 T:: Intraindividual comparative study with MR imaging at 1.5 T
    von Falkenhausen, Marcus M.
    Lutterbey, Goetz
    Morakkabati-Spitz, Nuschin
    Walter, Oliver
    Gieseke, Juergen
    Bloemer, Renate
    Willinek, Winfried A.
    Schild, Hans H.
    Kuhl, Christiane K.
    RADIOLOGY, 2006, 241 (01) : 156 - 166
  • [7] CLINICAL-EVALUATION OF IRREVERSIBLE IMAGE COMPRESSION - ANALYSIS OF CHEST IMAGING WITH COMPUTED RADIOGRAPHY
    ISHIGAKI, T
    SAKUMA, S
    IKEDA, M
    ITOH, Y
    SUZUKI, M
    IWAI, S
    RADIOLOGY, 1990, 175 (03) : 739 - 743
  • [8] Clinical evaluation of twin screen-film chest radiography: cost effective lung and mediastinal imaging
    McLean, D
    Gray, JE
    Swensen, SJ
    Vrieze, TJ
    EUROPEAN JOURNAL OF RADIOLOGY, 1998, 27 (01) : 61 - 66
  • [9] Line-scan diffusion tensor MR imaging at 0.2 T: Feasibility study
    Hori, M
    Aoki, S
    Okubo, T
    Ishigame, K
    Kumagai, H
    Araki, T
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (06) : 794 - 798
  • [10] Clinical evaluation of twin screen-film chest radiography: Cost effective lung and mediastinal imaging
    Sch. of Med. Radiation Technology, University of Sydney, PO Box 170, Sydney, NSW, Australia
    不详
    不详
    Eur. J. Radiol., 1 (61-66):