Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss

被引:32
|
作者
Cox-Reijven, PLM
van Kreel, B
Soeters, PB
机构
[1] Univ Hosp Maastricht, Dept Dietet, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, Dept Clin Chem, NL-6202 AZ Maastricht, Netherlands
[3] Univ Hosp Maastricht, Dept Surg, NL-6202 AZ Maastricht, Netherlands
关键词
D O I
10.1177/0148607102026002120
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: Bioelectrical impedance spectroscopy (BIS) is an attractive method for measuring body composition because it is noninvasive, simple, and cheap. The effect of obesity on the accuracy of impedance measurements has been recognized for some time, but no conclusive explanations or ways to correct the measurement errors have been published. We studied the effect of the composition of weight loss on the accuracy of BIS to measure changes in body fluid volumes during severe weight loss. Within subjects the effect of variable losses of fat mass was studied. Methods: In 10 morbidly obese female subjects who underwent gastric reduction surgery, changes in total body water (TBW) and extracellular water (ECW) were monitored for 1 year by deuterium (Deu) and bromide (Br) dilution and by BIS. Measurements were performed before the operation and after 2 weeks, 3 months, and 1 year. Extrapolated resistance values of extracellular (Recw) and intracellular water (Ricw) were used in mixture equations for calculating the corresponding fluid volumes. Results: After 1 year, weight decreased by 53 kg, TBW (Deu) loss was 8.7 L, and ECW (Br) loss was 4.3 L. Comparison of BIS with reference methods for measuring all possible changes over 6 time-intervals revealed a mean overestimation of TBW (2.4 L, SD = 2.9) and ECW (0.74 L, SD = 2.6) losses by BIS. Overestimation increased significantly with increasing fat losses, expressed as percentage fat of the weight loss and as change in triceps skinfolds. Measured changes in Recw and Ricw were less than expected for an ideal agreement between dilution methods and mixture equations. Conclusions: BIS with the use of mixture equations overestimates fluid losses during weight loss. The error is associated with the amount of fat loss. The large contribution of the factor weight in the mixture equations is likely to be responsible. The assumptions of mixture theory are not valid in obesity.
引用
收藏
页码:120 / 127
页数:8
相关论文
共 50 条
  • [31] Accuracy of Consumer Grade Bioelectrical Impedance Analyzers to Assess Body Composition.
    Barnas, Jillian
    Micinski, Natalie
    Wheatley, Laura
    Laurson, Kelly
    Thomas, David
    Brown, Dale
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 619 - 619
  • [32] Preoperative Body Composition Analysis as a Predictor of Weight Loss Outcomes Following Bariatric Surgery: A Bioelectrical Impedance Study
    Piero Giustacchini
    Giuseppe Marincola
    Simona Masia
    Valentina Milano
    Voltjan Sula
    Marco Raffaelli
    Obesity Surgery, 2025, 35 (3) : 685 - 693
  • [33] Bioelectrical impedance spectroscopy in an obese population before and after weight loss.
    Van Wijk, MCW
    Gill, TP
    Elia, M
    PROCEEDINGS OF THE NUTRITION SOCIETY, 2000, 59 : 42A - 42A
  • [34] Body Composition Assessment in Late Pregnancy by Bioelectrical Impedance and Neonatal Birth Weight
    Belghiti, H.
    Barkat, A.
    Elkari, Kh
    Kharbach, A.
    Mrabet, M.
    Bagri, A.
    Aguenaou, H.
    Lamdouar Bouazzaoui, N.
    INTERNATIONAL JOURNAL OF OBESITY, 2011, 35 : S53 - S53
  • [35] Bioelectrical impedance: The effect of exercise on bioelectrical impedance measurement and calculation of body composition
    Civar, S
    Ozer, K
    Gursel, E
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2006, 77 (01) : A37 - A38
  • [36] CHANGES IN FAT-FREE MASS DURING WEIGHT-LOSS MEASURED BY BIOELECTRICAL IMPEDANCE AND BY DENSITOMETRY
    DEURENBERG, P
    WESTSTRATE, JA
    HAUTVAST, JGAJ
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 49 (01): : 33 - 36
  • [37] Body mass index, bioelectrical impedance, and body composition
    Lukaski, HC
    NUTRITION, 2001, 17 (01) : 55 - 56
  • [38] Comparison of methods for assessing body composition changes during weight loss
    Weyers, AM
    Mazzetti, SA
    Love, DM
    Gómez, AL
    Kraemer, WJ
    Volek, JS
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (03): : 497 - 502
  • [39] Estimates of body composition during pregnancy using bioelectrical impedance analysis
    Toro-Ramos, Tatiana
    Hoffman, Daniel J.
    Sichieri, Rosely
    FASEB JOURNAL, 2012, 26
  • [40] Good agreement between bioelectrical impedance and dual-energy X-ray absorptiometry for estimating changes in body composition during weight loss in overweight young women
    Thomson, Rebecca
    Brinkworth, Grant D.
    Buckley, Jonathan D.
    Noakes, Manny
    Clifton, Peter M.
    CLINICAL NUTRITION, 2007, 26 (06) : 771 - 777