Determination of chitosan by cathodic stripping voltammetry

被引:16
|
作者
Lu, GH [1 ]
Wang, LR
Wang, RX
Zeng, Y
Huang, X
机构
[1] Cent China Normal Univ, Coll Chem, Wuhan 430079, Peoples R China
[2] Chizhou Coll, Dept Chem, Guichi 247000, Peoples R China
关键词
D O I
10.2116/analsci.22.575
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive method for the determination of chitosan (CTS) by cathodic stripping voltammetry is presented. The method exploits a pair of oxidation-reduction peaks of CTS at -0.62 V (vs. SCE) and -0.54 V (vs. SCE), and an enhancement of the peak current of CTS observed in a 0.05 mol 1(-1) potassium hydrogenphthalate buffer solution (pH 2.5). The peak current is linear with the concentration of CTS from 5.0 x 10(-7) to 1.5 x 10(-5) g ml(-1), and the detection limit is 1.0 x 10(-7) g ml(-1). We studied the characteristics and the mechanism of the electrode reaction, which proved that this process was diffusion controlled. This method was applied to determine the content of CTS in real samples with satisfactory results.
引用
收藏
页码:575 / 578
页数:4
相关论文
共 50 条
  • [31] THE DETERMINATION OF COBALT IN WATER SAMPLES BY CATHODIC STRIPPING VOLTAMMETRY
    GOLIMOWSKI, J
    TYKARSKA, A
    MELIAN, JAH
    PENA, JP
    CHEMIA ANALITYCZNA, 1995, 40 (02): : 201 - 206
  • [32] DETERMINATION OF PENICILLIN IN BIOLOGICAL SAMPLES BY CATHODIC STRIPPING VOLTAMMETRY
    SHCHUKINA, TI
    KATYUKHIN, VE
    SHTEINGARDT, YN
    BUKREEVA, EB
    JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 48 (02) : 262 - 264
  • [34] Indirect determination of boron in water by cathodic stripping voltammetry
    Sahin, Ibrahim
    Nakiboglu, Nuri
    FRESENIUS ENVIRONMENTAL BULLETIN, 2006, 15 (05): : 457 - 461
  • [35] Indirect determination of propranolol by cathodic adsorptive stripping voltammetry
    Ghoneim, MM
    Beltagi, AM
    Radi, A
    QUIMICA ANALITICA, 2002, 20 (04): : 237 - 241
  • [36] Determination of pyrithione in natural waters by cathodic stripping voltammetry
    Mackie, DS
    van den Berg, CMG
    Readman, JW
    ANALYTICA CHIMICA ACTA, 2004, 511 (01) : 47 - 53
  • [37] ONLINE DETERMINATION OF CHROMIUM BY ADSORPTIVE CATHODIC STRIPPING VOLTAMMETRY
    DOBNEY, AM
    GREENWAY, GM
    ANALYST, 1994, 119 (02) : 293 - 297
  • [38] CATHODIC STRIPPING VOLTAMMETRY AND ADSORPTIVE STRIPPING VOLTAMMETRY OF SELENIUM(IV)
    STARA, V
    KOPANICA, M
    ANALYTICA CHIMICA ACTA, 1988, 208 (1-2) : 231 - 236
  • [39] CATHODIC STRIPPING VOLTAMMETRY OF HGSE
    MATTSSON, G
    NYHOLM, L
    OLIN, A
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 377 (1-2): : 149 - 162
  • [40] THE CATHODIC PEAK IN STRIPPING VOLTAMMETRY
    FILANOVSKII, BK
    BUTYRSKAYA, LA
    SOKOLOV, MA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1987, 42 (10): : 1440 - 1442