Aim: The design and implementation of a wearable training device to improve cardiopulmonary resuscitation (CPR) is presented. Methods: The MYO contains both Electromyography (EMG) and Inertial Measurement Unit (IMU) sensors which are used to detect effective CPR, and the four common incorrect hand and arm positions viz. relaxed fingers; hands too low on the sternum; patient too close; or patient too far. The device determines the rate and depth of compressions calculated using a Fourier transform and dual-quaternions respectively. In addition, common positional mistakes are determined using classification algorithms (six machine learning algorithms are considered and tested). Feedback via Graphical User Interface (GUI) and audio is integrated. Results: The system is tested by performing CPR on a mannequin and comparing real-time results to theoretical values. Tests show that although the classification algorithm performed well in testing (98%), in real time, it had low accuracy for certain categories (60%) which are attributable to the MYO calibration, sampling rate and misclassification of similar hand positions. Combining these similar incorrect positions into more general categories significantly improves accuracy, and produces the same improved outcome of improved CPR. The rate and depth measures have a general accuracy of 97%. Conclusion: The system allows for portable, real-time feedback for use in training and in the field, and shows promise toward classifying and improving the administration of CPR.
引用
收藏
页码:183 / 189
页数:7
相关论文
共 50 条
  • [1] Real-time feedback systems for cardiopulmonary resuscitation training: time for a paradigm shift
    Cortegiani, Andrea
    Baldi, Enrico
    Iozzo, Pasquale
    Vitale, Filippo
    Raineri, Santi Maurizio
    Giarratano, Antonino
    JOURNAL OF THORACIC DISEASE, 2018, 10 (02) : E162 - E163
  • [2] Smartphone Application to Provide Real-Time Cardiopulmonary Resuscitation Quality Feedback
    Stumpf, Emily
    Ambati, Ravi
    Shekhar, Raj
    Staffa, Steven
    Zurakowski, David
    Sinha, Pranava
    CIRCULATION, 2019, 140
  • [3] A Smartphone application to provide real-time cardiopulmonary resuscitation quality feedback
    Stumpf, Emily
    Ambati, Ravi Tej
    Shekhar, Raj
    Staffa, Steven J.
    Zurakowski, David
    Sinha, Pranava
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2022, 60 : 34 - 39
  • [4] Cardiopulmonary resuscitation quality and beyond: the need to improve real-time feedback and physiologic monitoring
    Lin, Steve
    Scales, Damon C.
    CRITICAL CARE, 2016, 20
  • [5] Cardiopulmonary resuscitation quality and beyond: the need to improve real-time feedback and physiologic monitoring
    Steve Lin
    Damon C. Scales
    Critical Care, 20
  • [6] Real-Time Audiovisual Feedback Training Improves Cardiopulmonary Resuscitation Performance A Controlled Study
    Eshel, Ron
    Wacht, Oren
    Schwartz, Dagan
    SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2019, 14 (06): : 359 - 365
  • [7] Does the Real-Time Audio Feedback From an Automated External Defibrillator Enhance Cardiopulmonary Resuscitation Quality During Emergency Resuscitation?
    O'Hare, Peter
    Di Maio, Rebecca
    Torney, Hannah
    McIntyre, Colette
    McCanny, Paul
    Adgey, Jennifer
    CIRCULATION, 2013, 128 (22)
  • [8] Real-time activity monitoring using wireless wearable sensors
    Li, HQ
    Wu, JK
    Bao, XM
    Cheng, DL
    Dong, L
    PSC '05: PROCEEDINGS OF THE 2005 INTERNATIONAL CONFERENCE ON PERVASIVE SYSTEMS AND COMPUTING, 2005, : 117 - 123
  • [9] Using a smartwatch with real-time feedback improves the delivery of high-quality cardiopulmonary resuscitation by healthcare professionals
    Lu, Tsung-Chien
    Chang, Yao-Ting
    Ho, Te-Wei
    Chen, Yi
    Lee, Yi-Ting
    Wang, Yu-Siang
    Chen, Yen-Pin
    Tsai, Chu-Lin
    Ma, Matthew Huei-Ming
    Fang, Cheng-Chung
    Lai, Feipei
    Meischke, Hendrika W.
    Turner, Anne M.
    RESUSCITATION, 2019, 140 : 16 - 22
  • [10] Automated External Defibrillator with Real-Time Audiovisual Feedback System Improves the Quality of Cardiopulmonary Resuscitation
    Hayashi, Kenji
    Ushikoshi, Hiroaki
    Matsumaru, Naoki
    Nachi, Sho
    Nachi, Hikaru
    Morishita, Kentaro
    Sugihara, Hiroko
    Fukao, Ayumi
    Toyoda, Izumi
    Ogura, Shinji
    CIRCULATION, 2014, 130