Validation of the body fluid module on the new Sysmex XN-1000 for counting blood cells in cerebrospinal fluid and other body fluids

被引:79
|
作者
Fleming, Cherina [1 ]
Brouwer, Rob [1 ]
Lindemans, Jan [1 ]
de Jonge, Robert [1 ]
机构
[1] Univ Med Ctr Rotterdam, Dept Clin Chem, Erasmus MC, NL-3015 CE Rotterdam, Netherlands
关键词
body fluid; cerebrospinal fluid; counting chamber; hematology analyzer; leukocytes; Sysmex XN-1000; FLOW-CYTOMETRIC ANALYSIS; AUTOMATED HEMATOLOGY; PLEURAL FLUID; MODE; ANALYZERS; XE-5000;
D O I
10.1515/cclm-2011-0927
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We evaluated the body fluid (BF) module on the new Sysmex XN-1000 for counting blood cells. Methods: One hundred and eighty-seven BF samples [73 cerebrospinal fluid (CSF), 48 continuous ambulatory peritoneal dialysis (CAPD), 46 ascites, and 20 pleural fluid] were used for method comparison between the XN-1000 and manual microscopy (Fuchs-Rosenthal chamber and stained cytospin slides) for counting red blood cells (RBCs) and white blood cells (WBCs) (differential). Results: Good agreement was found for counting WBCs (y=1.06x+0.09, n=67, R-2=0.96) and mononuclear cells (MNs) (y=1.04x-0.01, n=40, R-2=0.93) in CSF. However, the XN-1000 systematically counted more polymorphonuclear cells (PMNs) (y=1.48x+0.18, n=40, R-2=0.99) compared to manual microscopy. Excellent correlation for RBCs >1x109/L (y=0.99x+116.56, n=26, R-2=0.99) in CSF was found. For other fluids (CAPD, ascites and pleural fluid) excellent agreement was found for counting WBCs (y=1.06x+0.26, n=109, R-2=0.98), MNs (y=1.06x-0.41, n=93, R-2=0.96), PMNs (y=1.06x+0.81, n=93, R-2=0.98) and RBCs (y=1.04x+110.04, n=43, R-2=0.98). By using BF XN-check, the lower limit of quantitation (LLoQ) for WBC was defined at 5x10(6)/L. Linearity was excellent for both the WBCs (R-2=0.99) and RBCs (R-2=0.99) and carry-over never exceeded 0.05%. Conclusions: The BF module on the XN-1000 is a suitable tool for fast and accurate quantification of WBC (differential) and RBC counts in CSF and other BFs in a diagnostic setting.
引用
收藏
页码:1791 / 1798
页数:8
相关论文
共 50 条
  • [31] Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer
    Cho, Y-U
    You, E.
    Jang, S.
    Park, C-J
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (03) : 258 - 267
  • [32] Determining White Blood Cell Count In Sterile Body Fluids: Cell Counting Chamber vs Sysmex UF-1000i
    Evren, Ebru
    Us, Ebru
    Karahan, Zeynep Ceren
    GAZI MEDICAL JOURNAL, 2020, 31 (01): : 19 - 21
  • [33] Preliminary evaluation of UF-5000 Body Fluid Mode for automated cerebrospinal fluid cell counting
    Seghezzi, Michela
    Manenti, Barbara
    Previtali, Giulia
    Alessio, Maria Grazia
    Dominoni, Paola
    Buoro, Sabrina
    CLINICA CHIMICA ACTA, 2017, 473 : 133 - 138
  • [34] Evaluation of Mindray BC-6800 body fluid mode for automated cerebrospinal fluid cell counting
    Buoro, Sabrina
    Seghezzi, Michela
    Mecca, Tommaso
    Vavassori, Mauro
    Crippa, Alberto
    La Gioia, Antonio
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (11) : 1799 - 1810
  • [36] Extent of agreement between the body fluid model of Sysmex XN-20 and the manual microscopy method
    Huang, Wei-Hua
    Lu, Lin-Peng
    Wu, Kang
    Guo, Fang-Yu
    Guo, Jie
    Yu, Jing-Long
    Zhou, Dao-Yin
    Sun, Yi
    Deng, An-Mei
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (05)
  • [37] A Comparative Proteomics Analysis of Five Body Fluids: Plasma, Urine, Cerebrospinal Fluid, Amniotic Fluid, and Saliva
    Zhao, Mindi
    Yang, Yehong
    Guo, Zhengguang
    Shao, Chen
    Sun, Haidan
    Zhang, Yang
    Sun, Ying
    Liu, Yaoran
    Song, Yijun
    Zhang, Liwei
    Li, Qian
    Liu, Juntao
    Li, Mingxi
    Gao, Youhe
    Sun, Wei
    PROTEOMICS CLINICAL APPLICATIONS, 2018, 12 (06)
  • [38] Evaluation of automated synovial fluid total cell count and percent polymorphonuclear leukocytes on a Sysmex XN-1000 analyzer for identifying patients at risk of septic arthritis
    Saadalla, Abdulrahman
    Aguirre, Jose Jara
    Wockenfus, Amy M.
    Kelley, Brandon R.
    Swanson, Rebecca L.
    Howard, Matthew T.
    Karon, Brad S.
    CLINICA CHIMICA ACTA, 2020, 510 : 416 - 420
  • [39] NEW SYSTEM FOR CULTIVATION OF FASTIDIOUS AND NON-FASTIDIOUS MICROBIAL AGENTS FROM CEREBROSPINAL-FLUID AND OTHER BODY-FLUIDS
    ABDOU, MAF
    STOECKEL, H
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIES A-MEDICAL MICROBIOLOGY INFECTIOUS DISEASES VIROLOGY PARASITOLOGY, 1982, 251 (04): : 454 - 455
  • [40] METRONIDAZOLE CONCENTRATIONS IN GINGIVAL CREVICE FLUID AND OTHER BODY-FLUIDS
    KOEKVANOOSTEN, MAC
    NOTTEN, FJW
    MIKX, FHM
    JOURNAL OF DENTAL RESEARCH, 1983, 62 (04) : 453 - 453