Analysis of Contact Resistance in Fault Parameter Identification Method and Its Suppression Methods

被引:0
|
作者
Chen, Wei [1 ]
Zou, Zhilong [1 ]
Yuan, Tao [2 ]
Liu, Nanjing [2 ]
Luo, Donghui [2 ]
Sun, Potao [2 ]
机构
[1] EHV Power Transmiss Co, Maintenance & Test Ctr, Guangzhou, Guangdong, Peoples R China
[2] Chongqing Univ, SKL PES, Chongqing, Peoples R China
关键词
grounding grid; corrosion diagnosis; contact resistance; inverse calculation; suppressing method;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The grounding grid is an important part of the power system. A good grounding grid status is related to the stable operation of the power system. Therefore, when a corrosion problem occurs in the grounding grid, the grounding resistance will increase, and the discharge of electrical energy will become unsmooth. This may lead to spark discharge between devices. What's worse, it may lead to device damage, resulting in a large area. Finally, it may affect the safe and stable operation of the power system. In grounding grid corrosion diagnosis, fault parameter identification method is one of the commonly used methods. By measuring the port resistance and performing inverse calculation to obtain the branch resistance change value, it also be-longs to fault parameter identification method. When measuring port resistance for ground grid corrosion diagnosis, since the digital DC bridge wire is not long enough, auxiliary wires need to be added between the digital DC bridge wire port and the down conductor steel. The contact resistance between the auxiliary wire and the down conductor steel will greatly affect the measured value of the port resistance, resulting in inaccurate inversion of the ground grid branch resistance. Therefore, in this paper, the influence of contact resistance on the corrosion diagnosis of grounding grid is studied by taking the grounding grid of the oil storage area as an example. The influence of the contact resistance on the inverse calculation is analyzed. The suppression method of the influence of the contact resistance in the corrosion diagnosis is also put forward and verified by the field test.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] EXPERIMENTAL MODAL ANALYSIS OF VIBRATING SYSTEMS: A METHOD FOR MODAL PARAMETER IDENTIFICATION AND ITS SOFTWARE PACKAGE.
    Kano, Hiroyuki
    Matsumoto, Fumio
    Kaneko, Junji
    Fujitsu Scientific and Technical Journal, 1987, 23 (01): : 55 - 69
  • [32] Sensitivity analysis-based classification and identification method of a synchronous condenser and its excitation system parameter
    Ma R.
    Zou S.
    Cao Y.
    Zhang H.
    Liu Z.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (04): : 26 - 37
  • [33] Parameter identification method for a three-dimensional foot-ground contact model
    Pamies-Vila, Rosa
    Font-Llagunes, Josep M.
    Lugris, Urbano
    Cuadrado, Javier
    MECHANISM AND MACHINE THEORY, 2014, 75 : 107 - 116
  • [34] A Kind Of Improved Adaptive Control Method And Its Application In Parameter Identification
    Peng, Jun
    Liu, Di
    Lei, Junwei
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND INTELLIGENT SYSTEMS (ICMEIS 2015), 2015, 26 : 277 - 281
  • [35] Inverse Rheological Hysteresis Model and its Efficient Parameter Identification Method
    Liu, Ren
    Lu, Youhao
    IEEE TRANSACTIONS ON MAGNETICS, 2024, 60 (03)
  • [36] Analysis of Kinematic Parameter Identification Method Based on Genetic Algorithm
    Yang, Jing
    Jin, Lingyan
    Han, Zejie
    Zhao, Deming
    Hu, Ming
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2021, PT I, 2021, 13013 : 119 - 128
  • [37] Parameter identification for nonlinear hysteresis damping with spectral analysis method
    Dong, XG
    Houghton, JR
    PROCEEDINGS OF THE 14TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I & II, 1996, 2768 : 343 - 348
  • [38] Parameter identification method based on wavelet Analysis of Time Window
    1600, International Frequency Sensor Association (164):
  • [39] A single terminal fault location method for single phase fault of cable based on parameter identification of metal sheath model
    Zhao T.
    Wang X.
    Yu Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (21): : 83 - 91
  • [40] Fault Identification of Rotating Electric Machines using Comparative Analysis Methods
    Balan, H.
    Vadan, I.
    Buzdugan, M.
    Botezan, A.
    Karaissas, P.
    INTERNATIONAL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS & ELECTROMOTION JOINT CONFERENCE, 2011, : 276 - 281