Transvaginal ultrasound probe contamination by the human papillomavirus in the emergency department

被引:43
|
作者
Ma, Shuk Ting Christine [1 ]
Yeung, A. C. [2 ]
Chan, Paul Kay Sheung [2 ]
Graham, Colin A. [1 ]
机构
[1] Chinese Univ Hong Kong, Accid & Emergency Med Acad Unit, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Microbiol, Fac Med, Shatin, Hong Kong, Peoples R China
关键词
ECTOPIC PREGNANCY; ULTRASONOGRAPHY; MANAGEMENT; INFECTION; DIAGNOSIS; RISK;
D O I
10.1136/emermed-2012-201407
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective To determine if human papillomavirus (HPV) DNA can be detected on the transvaginal sonography (TVS) probe in the emergency department (ED) and whether the current barrier method plus disinfection can prevent HPV contamination of the TVS probe. Methods This was a two-part cross-sectional study. In the first part, surveillance samples were taken from the TVS probe for HPV DNA detection daily for 2 months. In the second part, patients presenting with early pregnancy complications were identified in the ED and high vaginal swabs were taken for HPV DNA testing. Several probe swabs were taken to identify if contamination was possible in cases where the procedure was done on an HPV carrier. Results A total of 120 surveillance samples were obtained, nine of which (7.5%) tested positive for HPV DNA. In the second part, 76 women were recruited, of whom 14 (18.4%) were HPV carriers. After the procedure and disinfection of the probe, three out of the 14 probe samples (21%) were HPV DNA positive. Conclusions HPV is commonly encountered in the ED and contamination of the TVS probe with HPV is possible. Although it is difficult to prove the viability and infectivity of the virus, vigilant infection control measures should be maintained.
引用
收藏
页码:472 / 475
页数:4
相关论文
共 50 条
  • [21] MRSA Contamination of Emergency Department Ultrasonography Probes
    Sanz, G. E.
    Theoret, J.
    Michael, L. M.
    Erickson, C.
    Kendall, J. L.
    ANNALS OF EMERGENCY MEDICINE, 2010, 56 (03) : S116 - S116
  • [22] Reducing Blood Culture Contamination in the Emergency Department
    McLeod, Casey G.
    JOURNAL OF NURSING CARE QUALITY, 2020, 35 (03) : 245 - 251
  • [23] Keeping Up With Emergency Department Ultrasound
    Regan, Linda
    ACADEMIC EMERGENCY MEDICINE, 2011, 18 (03) : 309 - 310
  • [24] Anal canal ultrasound: Transvaginal evaluation with an end fire probe
    Montorfano, Miguel
    Pla, Fernando
    Torres, Monica
    Ricci, Sergio
    Roasio, Carlos
    Vera, Leonardo
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [25] Analysis of the integrity of ultrasound probe covers used for transvaginal examinations
    Basseal, Jocelyne M.
    Westerway, Susan Campbell
    Hyett, Jon A.
    INFECTION DISEASE & HEALTH, 2020, 25 (02) : 77 - 81
  • [26] Evolving role of ultrasound in the emergency department
    Thompson, Peter
    EMERGENCY MEDICINE AUSTRALASIA, 2008, 20 (05) : 375 - 378
  • [27] Musculoskeletal Ultrasound in the Emergency Department: Is There a Role?
    Perone, Michael, V
    Yablon, Corrie M.
    SEMINARS IN ROENTGENOLOGY, 2021, 56 (01) : 115 - 123
  • [28] Pediatric Ultrasound Applications in the Emergency Department
    Leeson, Kimberly
    Leeson, Ben
    EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 2013, 31 (03) : 809 - +
  • [29] Bedside ultrasound in the pediatric emergency department
    Levy, Jason A.
    Bachur, Richard G.
    CURRENT OPINION IN PEDIATRICS, 2008, 20 (03) : 235 - 242
  • [30] Emergency department ultrasound by nurse practitioners
    Henderson, Sean O.
    Ahern, Terence
    Williams, David
    Mailhot, Thomas
    Mandavia, Diku
    JOURNAL OF THE AMERICAN ACADEMY OF NURSE PRACTITIONERS, 2010, 22 (07): : 352 - 355