Improvement in the applicability of the air tightness measurement using a sudden expansion of compressed air

被引:11
|
作者
Bae, Sungryong [1 ]
Moon, Hyojun [1 ]
Lee, Min Jung [1 ]
Kim, Nam Il [1 ]
Ryou, Hong Sun [1 ]
机构
[1] Chung Ang Univ, Sch Mech Engn, Seoul 156756, South Korea
关键词
Air tightness; Effective leakage area; Smoke suppression; Fire safety; Sudden expansion; HOUSES; FIRE;
D O I
10.1016/j.buildenv.2012.12.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air tightness is an important parameter for both smoke suppression in a fire and for the energy efficiency of buildings. A transient method using a sudden expansion of compressed air (SECA) was recently introduced to measure the air tightness, or effective leakage area, with the least amount of labor or preparation. Although the feasibility of SECA has been reported, relevant experimental data has been limited to small leakage areas of up to 20 cm(2), which has not been sufficient to cover the leakage of rooms in buildings. In this study, a test room and the test module for SECA were modified and the basic equation of the transient method was improved. As a result, the application limit of the leakage area can be extended up to 700 cm(2), and further extension would be possible simply by increasing the chamber volume or its initial pressure. The experimental results of SECA can be related theoretically to the results of a steady method, and they were not affected by the volume of the room. The results of this study will help prove the most convenient measurements for air tightness and for the effective leakage areas in rooms and ventilation systems. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [31] Air power - Using compressed air to replace internal combustion in the power train
    Frank, Michael
    Automotive Industries AI, 2007, 187 (07):
  • [32] Microgrid Expansion through a Compressed Air Assisted Wind Energy System
    Cheng, Jie
    Choobineh, Fred
    2016 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2016,
  • [33] Electronic odour measurement systems and applicability in ambient air control
    Heining, Kai
    Wiese, Bernd
    Gefahrstoffe Reinhaltung der Luft, 2000, 60 (05): : 195 - 200
  • [34] Electronic odour measurement systems and applicability in ambient air control
    Heining, K
    Wiese, B
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2000, 60 (05): : 195 - 200
  • [35] Improvement of the air tightness and corrosive resistance of connecting threads of oil-well tubing
    Proskurkin, EV
    Sukhomlin, AI
    Shanilov, VA
    Fartushnyi, NI
    Prokhorov, NN
    NEFTYANOE KHOZYAISTVO, 1998, (9-10): : 81 - 83
  • [36] Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance
    Kim, Hyung-Mok
    Rutqvist, Jonny
    Ryu, Dong-Woo
    Choi, Byung-Hee
    Sunwoo, Choon
    Song, Won-Kyong
    APPLIED ENERGY, 2012, 92 : 653 - 667
  • [37] Combustion of premixed fuel and air downstream of a plane sudden-expansion
    L. Khezzar
    S. R. N. De Zilwa
    J. H. Whitelaw
    Experiments in Fluids, 1999, 27 : 296 - 309
  • [38] Combustion of premixed fuel and air downstream of a plane sudden-expansion
    Khezzar, L
    De Zilwa, SRN
    Whitelaw, JH
    EXPERIMENTS IN FLUIDS, 1999, 27 (04) : 296 - 309
  • [39] Malodorous air measurement in the atmosphere by using the air monitoring system
    Aoyama, Y
    Yoshimura, T
    Yamada, A
    DENKI KAGAKU, 1998, 66 (06): : 641 - 647
  • [40] Mathematical Modelling of a System for Solar PV Efficiency Improvement Using Compressed Air for Panel Cleaning and Cooling
    King, Marcus
    Li, Dacheng
    Dooner, Mark
    Ghosh, Saikat
    Roy, Jatindra Nath
    Chakraborty, Chandan
    Wang, Jihong
    ENERGIES, 2021, 14 (14)