The development of a new method for the determination of concentrations of carbonaceous gases using a non-dispersive infrared sensor

被引:4
|
作者
Liu, Haibo [1 ]
Chen, Tianhu [1 ]
Chen, Dong [1 ]
Chang, Dongyin [1 ]
Frost, Ray L. [2 ]
机构
[1] Hefei Univ Technol, Sch Resource & Environm Engn, Hefei, Peoples R China
[2] Queensland Univ Technol, Fac Sci & Technol, Chem Discipline, Brisbane, Qld 4001, Australia
基金
美国国家科学基金会; 高等学校博士学科点专项科研基金;
关键词
Non-dispersive infrared sensor (NDIR); Carbonaceous gas; Calibration plot; Related coefficient; Reproducibility; BIOMASS GASIFICATION; STEAM; CATALYSTS; NAPHTHALENE; DOLOMITE;
D O I
10.1016/j.fuel.2012.07.063
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An analytical method for the detection of carbonaceous gases by a non-dispersive infrared sensor (NDIR) has been developed. The calibration plots of six carbonaceous gases including CO2, CH4, CO, C2H2, C2H4 and C2H6 were obtained and the reproducibility determined to verify the feasibility of this gas monitoring method. The results prove that squared correlation coefficients for the six gas measurements are greater than 0.999. The reproducibility is excellent, thus indicating that this analytical method is useful to determinate the concentrations of carbonaceous gases. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:749 / 751
页数:3
相关论文
共 50 条
  • [31] On-Chip Non-Dispersive Infrared CO2 Sensor Based on an Integrating Cylinder
    Jia, Xiaoning
    Roels, Joris
    Baets, Roel
    Roelkens, Gunther
    SENSORS, 2019, 19 (19)
  • [32] Belief Function Fusion based Self-calibration for Non-dispersive Infrared Gas Sensor
    You, Yang
    Xu, Anran
    Oechtering, Tobias J.
    2020 IEEE SENSORS, 2020,
  • [33] Non-dispersive infrared (NDIR) sensor for real-time nitrate monitoring in wastewater treatment
    Roodenko, K.
    Hinojos, D.
    Hodges, K.
    Veyan, J. -F.
    Chabal, Y. J.
    Clark, K. P.
    Katzir, A.
    Robbins, D.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XIX, 2019, 10872
  • [34] Enrichment-layer based miniaturized non-dispersive infrared CO2 sensor
    Moumen, Sarra
    Raible, Isabelle
    Krauss, Andreas
    Woellenstein, Juergen
    EUROSENSORS 2015, 2015, 120 : 400 - 405
  • [35] A review on non-dispersive infrared gas sensors: Improvement of sensor detection limit and interference correction
    Trieu-Vuong Dinh
    Choi, In-Young
    Son, Youn-Suk
    Kim, Jo-Chun
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 529 - 538
  • [36] Research of Weak Signal Processing Circuit Based on Non-dispersive Infrared Automobile Exhaust Sensor
    Xie, Jun
    Zhang, Yilong
    Yuan, Yuefeng
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS II, PTS 1-3, 2013, 336-338 : 163 - +
  • [37] Light Powered Battery-less Non-Dispersive Infrared Sensor for Methane Gas Detection
    Fleming, Lewis
    Ahmadzadeh, Sam
    Pomfret, Jonathan
    Waddell, Ewan
    McGann, Greg
    Hutson, David
    Keel, Emma
    Kauer, Matthias
    Bellanger, Matthieu
    Brinkley, Ian
    Gibson, Des
    OPTICAL SENSING AND DETECTION VIII, 2024, 12999
  • [38] Development of a flat conical chamber-based non-dispersive infrared CO2 gas sensor with temperature compensation
    Zhang, Jiahong
    Lu, Chunling
    Gu, Fang
    Liu, Qingquan
    Wang, Mengjuan
    Li, Dalin
    Han, Zhu
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (05):
  • [39] A Novel Bandpass Filter for the Analysis of Carbon Monoxide Using a Non-Dispersive Infrared Technique
    Dinh, Trieu-Vuong
    Ahn, Ji-Won
    Choi, In-Young
    Kim, Jo-Chun
    ATMOSPHERE, 2018, 9 (12):
  • [40] DETERMINATION OF IRON AND TITANIUM IN KAOLINS BY METHOD OF NON-DISPERSIVE X-RAY-FLUORESCENCE
    BIALY, N
    KIERZEK, J
    PARUS, J
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1976, 34 (02): : 365 - 373