Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of leucine in biological and pharmaceutical samples

被引:31
|
作者
Rezaei, B. [1 ]
Zare, Z. Mirahmadi [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan, IR, Iran
关键词
cyclic voltammetry; electrocatalytic; leucine; modified glassy carbon electrode; multiwall carbon nanotubes;
D O I
10.1080/00032710802238036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and highly sensitive method is described for voltammetric determination of leucine in blood and urine samples; namely, a glassy carbon electrode with an effective method is modified with multiwall carbon nanotubes (MWNTs). The cyclic voltammetric results indicated that MWNTs remarkably enhanced electrocatalytic activity toward the oxidation of leucine. Under the optimum condition the calibration curve was linear in the concentration range 9.0 x 10(-6) 1.5 x 10(-3) mol L-1, with the detection limit of 3.0 x 10(-6) mol L-1 and a relative standard deviation (RSD%) lower than 3.0% (n = 5). Also, some kinetic parameters were determined and a multistep mechanism for oxidation of leucine was proposed.
引用
收藏
页码:2267 / 2286
页数:20
相关论文
共 50 条
  • [41] Voltammetric Determination of Penicillamine Using a Carbon Paste Electrode Modified with Multiwall Carbon Nanotubes In the Presence of Methyldopa as a Mediator
    Safari, Fardin
    Keyvanfard, Mohsen
    Karimi-Maleh, Hassan
    Alizad, Khadijeh
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2017, 16 (03): : 1019 - 1029
  • [42] Voltammetric determination of tinidazole using a glassy carbon electrode modified with single-wall carbon nanotubes
    Yang, CH
    ANALYTICAL SCIENCES, 2004, 20 (05) : 821 - 824
  • [43] Voltammetric determination of the herbicide propham on glassy carbon electrode modified with multi-walled carbon nanotubes
    Leniart, Andrzej
    Brycht, Mariola
    Burnat, Barbara
    Skrzypek, Slawomira
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 54 - 63
  • [44] Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples
    Kassa, Adane
    Amare, Meareg
    Benor, Amare
    Tigineh, Getinet Tamiru
    Beyene, Yonas
    Tefera, Molla
    Abebe, Atakilt
    ACS OMEGA, 2022, : 34599 - 34607
  • [45] Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes
    Salimi, A
    Hallaj, R
    Khayatian, GR
    ELECTROANALYSIS, 2005, 17 (10) : 873 - 879
  • [46] Electrochemical Determination of Acetaminophen Using Gold Nanoparticles-Multiwall Carbon Nanotubes Modified Glassy Carbon Electrode
    Peng, Youyuan
    Zheng, Zhifu
    AMERICAN LABORATORY, 2014, 46 (09) : 16 - 19
  • [47] A new voltammetric sensor for the determination of sulfite in water and wastewater using modified-multiwall carbon nanotubes paste electrode
    Ensafi, Ali A.
    Karimi-Maleh, Hassan
    Keyvanfard, M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (06) : 650 - 660
  • [48] Electrochemical Determination of Cu(II) Using a Glassy Carbon Electrode Modified with Multiwall Carbon Nanotubes Dispersed in Polyhistidine
    Dalmasso, Pablo R.
    Pedano, Maria L.
    Rivas, Gustavo A.
    ELECTROANALYSIS, 2015, 27 (09) : 2164 - 2170
  • [49] Development of a sensitive voltammetric sensor for diltiazem determination in biological samples using MWCNT/PPy-PBA modified glassy carbon electrode
    Ostovar, Sahar
    Maghsoudi, Shahab
    Mousavi, Mehdi
    SYNTHETIC METALS, 2021, 281
  • [50] Voltammetric Determination of N-Actylcysteine Using Modified Multiwall Carbon Nanotubes Paste Electrode
    Karimi-Maleh, Hassan
    Keyvanfard, Mohsen
    Alizad, Khadijeh
    Fouladgar, Masoud
    Beitollahi, Hadi
    Mokhtari, Ali
    Gholami-Orimi, Fathali
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (12): : 6141 - 6150