Comparison of Point-of-Care Testing Methods and Laboratory Analysis for Assessing Urine Specific Gravity and pH of Children Undergoing Chemotherapy

被引:1
|
作者
Kalbfeld, Karen [1 ]
Parkosewich, Janet A. [2 ]
Teng, Wei [3 ]
Funk, Marjorie [4 ]
机构
[1] Yale New Haven Childrens Hosp, New Haven, CT USA
[2] Yale New Haven Med Ctr, 20 York St, New Haven, CT 06504 USA
[3] Yale New Haven Hlth Syst, Joint Data Analyt Team, New Haven, CT USA
[4] Yale Sch Nursing, Nursing, West Haven, CT USA
关键词
point-of-care urine testing; pediatric; chemotherapy; cancer; REAGENT; NEPHROTOXICITY; RECOMMENDATIONS; HYDRATION;
D O I
10.1177/1043454220958652
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background To reduce the risk of renal toxicity, urine specific gravity (SG) and pH (potential of hydrogen) parameters should be met before nephrotoxic chemotherapeutic agents are administered. The purpose of this study was to compare laboratory urine SG and pH values with those obtained with urine point-of-care (POC) testing methods commonly used when caring for children receiving nephrotoxic chemotherapeutic agents. Method A method-comparison design was used to compare the values of three POC methods for SG (dipstick, automated dipstick reader, refractometer) and three pH (dipstick, automated dipstick reader, litmus paper) methods with laboratory analysis of 86 urine samples from 43 children hospitalized on a pediatric hematology oncology unit in a large academic medical center. The Bland-Altman method was used to calculate bias and precision between POC and laboratory values. Results Except for the SG refractometer, bias values from Bland-Altman graphs demonstrated poor agreement between POC and laboratory urine SG and pH results. The precision values between these methods indicated overestimation or underestimation of hydration or urine pH status. Compared with laboratory methods, 31% of POC visual reading of dipstick SG values were falsely low-putting the patient at risk of not receiving necessary hydration and subsequent nephrotoxicity. Discussion In conclusion, most POC urine testing methods for SG and pH are not accurate compared with laboratory analysis. Because laboratory analyses can take longer than POC methods to obtain results, clinicians need to collaborate with laboratory medicine to ensure that an expedited process is in place in order to prevent chemotherapy administration delays.
引用
收藏
页码:6 / 15
页数:10
相关论文
共 50 条
  • [21] Hyponatraemia: the importance of obtaining a detailed history and corroborating point-of-care analysis with laboratory testing
    Lim, Su Yin
    Bodagh, Neil
    Scott, Gregory
    Hill, Neil E.
    BMJ CASE REPORTS, 2019, 12 (12)
  • [22] Comparison of point-of-care testing and laboratory testing of myocardial damage markers in the diagnosis and prognosis of acute coronary syndrome
    杨军
    China Medical Abstracts(Internal Medicine), 2013, 30 (01) : 1 - 2
  • [23] Evaluating Urine pH and Specific Gravity: A Single-Center Experience Comparing Different Urine Testing Methods in Children Receiving High-Dose Methotrexate
    Ali, Zain
    Chyu, Joanna
    Almekdash, Mhd Hasan
    Al-Rahawan, Mohamad M.
    CLINICAL LYMPHOMA MYELOMA & LEUKEMIA, 2021, 21 : S265 - S266
  • [24] A contemporaneous inr comparison of point-of-care instruments designed for monitoring oral anticoagulation with standard laboratory methods
    Gosselin, RC
    Owings, JT
    White, RH
    Hutchinson, R
    Branch, J
    Mahackian, K
    Larkin, EC
    THROMBOSIS AND HAEMOSTASIS, 1999, : 547 - 548
  • [25] Comparison of emergency department patient classification by point-of-care and central laboratory methods for cardiac troponin I
    Bock, Jay L.
    Singer, Adam J.
    Thode, Henry C., Jr.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (01) : 132 - 135
  • [26] C-reactive protein point-of-care testing in acutely ill children: a mixed methods study in primary care
    Van den Bruel, Ann
    Jones, Caroline
    Thompson, Matthew
    Mant, David
    ARCHIVES OF DISEASE IN CHILDHOOD, 2016, 101 (04) : 382 - 385
  • [27] A Comparison Study Between Point-of-Care Testing Systems and Central Laboratory for Determining Blood Glucose in Venous Blood
    Wei, Huiping
    Lan, Fang
    He, Qitian
    Li, Haiwei
    Zhang, Fuyong
    Qin, Xue
    Li, Shan
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (03)
  • [28] Point-of-care testing for prothrombin time, but not activated partial thromboplastin time, correlates with laboratory methods in patients receiving antifibrinolytic agents while undergoing cardiac surgery
    Choi, T
    Greilich, PE
    Shi, C
    Wilson, JS
    Keller, A
    Kroll, M
    Markin, V
    TRANSFUSION, 2000, 40 (10) : 128S - 128S
  • [29] POINT-OF-CARE VERSUS CENTRAL LABORATORY TESTING - AN ECONOMIC-ANALYSIS IN AN ACADEMIC-MEDICAL-CENTER
    TSAI, WW
    NASH, DB
    SEAMONDS, B
    WEIR, GJ
    CLINICAL THERAPEUTICS, 1994, 16 (05) : 898 - 910
  • [30] Assessing the cost-effectiveness of point-of-care testing for patients with symptoms suggestive of ACS in primary care: a threshold analysis
    Moesker, M. J.
    Steuten, L. M. G.
    Kip, M. M. A.
    Kusters, R. G. C. M.
    ACTA CLINICA BELGICA, 2015, 70 : S13 - S14