Multidimensional low-power pulse EPR under DNP conditions

被引:22
|
作者
Granwehr, J. [1 ]
Koeckenberger, W. [1 ]
机构
[1] Univ Nottingham, Sch Phys & Astron, Sir Peter Mansfield Magnet Resonance Ctr, Nottingham NG7 2RD, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1007/s00723-008-0133-5
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Several different processes and potentially even multiple different mechanisms are involved in the dynamic nuclear polarization (DNP) of bulk nuclei in a solid matrix doped with paramagnetic centers. This has to date prevented the quantification of DNP on the basis of a mechanistic understanding for paramagnetic agents with an electron paramagnetic resonance (EPR) spectrum broader than the Larmor frequency of the nuclei that are polarized. To compare theoretical models with experiments, it is necessary to gather experimental data to quantify all the involved processes. On the basis of an EPR setup using the same unstabilized microwave source as is used for DNP, we present multidimensional correlation EPR experiments to study the electron spin dynamics under DNP conditions. Low-power pulse EPR methods are used to measure the transient saturation and saturation-recovery on a timescale of tens to hundreds of milliseconds. Furthermore, the absence of a microwave resonator or cavity enables us to perform pump-probe experiments with switching of the microwave frequency. The correlation patterns obtained with these electron-electron double-resonance experiments can be used to analyze spectral diffusion in the EPR spectrum of the investigated radicals. In addition to studying the dynamical properties of the electron spins, it is shown for TEMPO in a glassy matrix that these experiments can be used to directly measure DNP of strongly hyperfine-coupled nuclei, in this case the nitroxyl-N-14.
引用
收藏
页码:355 / 378
页数:24
相关论文
共 50 条
  • [31] A PULSE STREAM SYSTEM FOR LOW-POWER NEURO-FUZZY COMPUTATION
    CHIABERGE, M
    SOLOGUREN, EM
    REYNERI, LM
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 1995, 42 (11) : 946 - 954
  • [32] ANTIBODY-RESPONSES OF MICE EXPOSED TO LOW-POWER MICROWAVES UNDER COMBINED, PULSE-AND-AMPLITUDE MODULATION
    VEYRET, B
    BOUTHET, C
    DESCHAUX, P
    DESEZE, R
    GEFFARD, M
    JOUSSOTDUBIEN, J
    LEDIRAISON, M
    MOREAU, JM
    CARISTAN, A
    BIOELECTROMAGNETICS, 1991, 12 (01) : 47 - 56
  • [33] Experimental Study on Two-phase Natural Circulation Characteristics under Low-voltage and Low-power Conditions
    Liu X.
    Zhang Y.
    Jiang L.
    Jiao M.
    Zhao X.
    Wang X.
    Wang X.
    Hedongli Gongcheng/Nuclear Power Engineering, 2022, 43 (05): : 82 - 88
  • [34] Low-power implantable CMOS bipolar Gaussian monocycle pulse generator
    Wang, Kun
    Li, Bin
    Zhao, Ming Jian
    Wu, Zhao Hui
    ELECTRONICS LETTERS, 2017, 53 (03) : 201 - U76
  • [35] Low-Noise, Low-Power Pulse Shaper for Particle Detection (Invited Paper)
    Webb, Devon
    Song, Yixin
    Rozsa, Jace
    Gustafson, Elaura
    Austin, Daniel E.
    Hawkins, Aaron R.
    Chiang, Shiuh-hua Wood
    2020 IEEE 63RD INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2020, : 301 - 304
  • [36] SPEED OF RESPONSE OF LOW-POWER OPERATIONAL-AMPLIFIERS OPERATING UNDER LARGE-SIGNAL CONDITIONS
    KAPITONOV, MV
    PROKOPENKO, NN
    ROGACH, AI
    YUGAI, V
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1979, 33-4 (08) : 98 - 99
  • [37] Design of a Low-Power Radio Frequency Unit and Its Application for Bacterial Inactivation under Laboratory Conditions
    Kozak, Dmytro S.
    Tonti, Maria
    Cuba, Patricia
    Espitia, Julian
    Tsepelev, Vladimir S.
    Verheyen, Davy
    Akkermans, Simen
    Van Impe, Jan F. M.
    APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [38] BWR NATURAL CIRCULATION EXPERIMENTS AT ROSA-III UNDER LOW-POWER AND REDUCED INVENTORY CONDITIONS
    ANODA, Y
    NAKAMURA, H
    KUKITA, Y
    TASAKA, K
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1988, 25 (02) : 143 - 152
  • [39] Rationalizing dissent? Challenging conditions of low-power FM radio
    Hamilton, J
    CRITICAL STUDIES IN MEDIA COMMUNICATION, 2004, 21 (01) : 44 - 63
  • [40] A low-cost implementation of EPR detection in a dissolution DNP setup
    Granwehr, Josef
    Leggett, James
    Kockenberger, Walter
    JOURNAL OF MAGNETIC RESONANCE, 2007, 187 (02) : 266 - 276