Therapeutic effect of an external fixator in the treatment of unstable pelvic fractures in children

被引:3
|
作者
Zhu, Danjiang [1 ]
Liu, Dingwu [1 ]
Song, Baojian [1 ]
Feng, Wei [1 ]
Zhang, Xuejun [1 ]
Wang, Qiang [1 ]
机构
[1] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Orthopaed, 56 Nalishi Rd, Beijing 100045, Peoples R China
关键词
Children; Pelvic fracture; External fixator; RING INJURIES; OUTCOMES;
D O I
10.1016/j.otsr.2021.103150
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unstable pelvic fractures in children are serious and complex injuries, and the optimal method to manage these injuries is controversial. Hypothesis: We hypothesized that an external fixator would be a satisfactory method of treating unstable pelvic fractures in children. Patients and Methods: We retrospectively reviewed 40 pediatric patients with unstable pelvic fractures who were treated with an external fixator in Beijing Children's Hospital from June 2006 to June 2016. Postoperative follow-up was 12 to 108 months, with an average of 26 months. One year after the operation, fracture healing, pelvic asymmetry, and deformity index were assessed by X-ray. Pelvic function was evaluated with the Cole evaluation standard, and daily cognitive and motor functions were evaluated by weeFIM. Patient complications were recorded. Results: The average age of the 40 patients was 5.9 +/- 3.1 years (2 to 14.5), including 25 boys and 15 girls. Among these cases, 37 (92.5%) had injuries caused by traffic accidents and 3 (7.5%) had injuries caused by falling from height. Based on the Tile classification, there were 18 cases of class B (14 class B2 and 4 class B3) and 22 cases of class C (15 class C1, 6 class C2, and 1 class C3). The X-rays showed good fracture healing at the 1-year postoperative follow-up. The pelvic asymmetry was reduced from 1.13 cm before the operation to 0.88 cm after (p < 0.05), and the deformity index was decreased from 0.09 before to 0.05 after the operation (p < 0.05). At the 1-year postoperative follow-up, 36 patients had excellent Cole scores, and 4 had good Cole scores, with a good or excellent rate of 100%. According to the weeFIM, 28 patients had complete independence, 11 had basic independence, and 1 had conditional independence. Three patients (7.5%) had complications, all of which were postoperative pin-site infections. Discussion: For children with horizontally unstable pelvic fractures, an external fixator can be used alone. For children with horizontally and vertically unstable pelvic fractures, after external fixator placement and reduction, lower extremity traction can be performed to achieve better reduction and maintain stability, and the therapeutic effect is satisfactory. (C) 2021 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] TREATMENT OF UNSTABLE PELVIC RING FRACTURES BY EXTERNAL FIXATION WITH A WAGNER APPARATUS
    MULLER, J
    BACHMANN, B
    HELVETICA CHIRURGICA ACTA, 1978, 45 (1-2) : 59 - 61
  • [22] Treatment of distal metaphyseal tibia fractures using an external fixator in children
    Dai, Jin
    Wang, Xiaodong
    Zhang, Fuyong
    Zhu, Lunging
    Zhen, Yunfang
    MEDICINE, 2019, 98 (36)
  • [23] Treatment of acute proximal humeral fractures in children with modular external fixator
    Bisaccia, Michele
    Meccariello, Luigi
    Manni, Mattia
    Falzarano, Gabriele
    Medici, Antonio
    Rinonapoli, Giuseppe
    Di Giacinto, Salvatore
    Colleluori, Giovanni
    Vicente, Cristina Ibanez
    Ceccarini, Paolo
    Bisaccia, Olga
    Caraffa, Auro
    JOURNAL OF ACUTE DISEASE, 2016, 5 (06) : 497 - 501
  • [24] External fixator as a safe method in the treatment of distal tibial fractures in children
    Wen, Yuwei
    Zhu, Danjiang
    Wang, Qiang
    Song, Baojian
    Feng, Wei
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2024, 33 (03): : 233 - 239
  • [25] IMMEDIATE EXTERNAL FIXATION OF UNSTABLE PELVIC FRACTURES
    GYLLING, SF
    WARD, RE
    HOLCROFT, JW
    BRAY, TJ
    CHAPMAN, MW
    AMERICAN JOURNAL OF SURGERY, 1985, 150 (06): : 721 - 724
  • [26] The Radiological and Functional Outcomes of Pelvic Fractures Treated by External Fixator
    Bux, Husain
    Imamuddin
    Azeem, Nazia
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (10): : 3458 - 3459
  • [27] Influence of external pelvic stabilization on hemodynamically unstable pelvic fractures
    Esmer, E.
    Esmer, E.
    Derst, P.
    Schulz, M.
    Siekmann, H.
    Delank, K. S.
    UNFALLCHIRURG, 2017, 120 (04): : 312 - 319
  • [29] Use of the Hoffman 2 compact external fixator in the treatment of redisplaced unstable distal radial fractures
    McQueen, MM
    Simpson, D
    Court-Brown, CM
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (07) : 501 - 505
  • [30] HUGHES EXTERNAL FIXATOR IN TREATMENT OF TIBIAL FRACTURES
    COURTBROWN, CM
    HUGHES, SPF
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1985, 78 (10) : 830 - 837