MTF non-redundant distribution for multi-piston errors detection of segmented telescopes

被引:1
|
作者
Zhao, Weirui [1 ]
Liu, Tiantian [1 ]
Zhang, Lu [1 ]
Zhao, Yuejin [1 ]
机构
[1] Beijing Inst Technol, Beijing Key Lab Precis Optoelect Measurement Inst, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Fourier transform; MTF sidelobes; piston error; interferometry; diffraction; non-redundant distribution; TILT INTERFEROMETRY; MIRROR SEGMENTS; KECK TELESCOPES; PISTON;
D O I
10.1117/12.2556326
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We propose a MTF non-redundant distribution method, with which the multi-piston errors of segmented telescope can be detected simultaneously. A mask with a sparse multi-subaperture configuration is set in the exit pupil of the segmented telescope. One subaperture matches to one segment and samples the wave-front reflected by this segment. Coherent diffraction patterns, produced by each pair of the wave-fronts, are recorded as point spread function (PSF). A Fourier transform is performed for the PSF to obtain the optical transfer function (OTF). Then, relationship between the piston error and the amplitudes of the MTF sidelobes is derived. The piston error can be retrieved accurately by this relationship, and the capture range is the coherent length of the operating light. The key to realize a multi-piston errors simultaneous detection using this relationship is to avoid overlap of the MTF sidelobes which formed by each pair of subwaves. We research and derive the MTF model of a mask with a sparse multi-subaperture configuration. According to Fourier optics principle, the MTF distribution of this model is analyzed, and rules for the MTF sidelobes non-redundant distribution are obtained. Simulations have been done to validate the rules. Taking an 18-segment mirror as an example, a mask with a sparse 18 sub-apertures configuration is designed to realize the MTF sidelobes non-redundant distribution. Thus, just need to set a mask with a sparse multi-subaperture configuration in the conjugate plane of the segmented mirror, the piston errors of the full aperture can be retrieved simultaneously.
引用
收藏
页数:9
相关论文
共 48 条
  • [41] A non-redundant, reference viral database (RVDB) to facilitate high-throughput sequencing (HTS) analysis for virus detection
    Goodacre, Norman
    Nandakumar, Subhiksha
    Aljanahi, Aisha
    Khan, Arifa
    JOURNAL OF MEDICAL PRIMATOLOGY, 2018, 47 (05) : 335 - 335
  • [42] Three-Dimensional Probe Mispositioning Errors Compensation: A Feasibility Study in the Non-Redundant Helicoidal Near to Far-Field Transformation Case
    D'Agostino, Francesco
    Ferrara, Flaminio
    Gennarelli, Claudio
    Guerriero, Rocco
    Migliozzi, Massimo
    Pascarella, Luigi
    Riccio, Giovanni
    ELECTRONICS, 2024, 13 (18)
  • [43] Multi-fault diagnosis strategy based on a non-redundant interleaved measurement circuit and improved fuzzy entropy for the battery system
    Ren, Song
    Sun, Jing
    ENERGY, 2024, 292
  • [44] An Effective Iterative Algorithm to Correct the Probe Positioning Errors in a Non-Redundant Plane-Rectangular Near-Field to Far-Field Transformation
    D'Agostino, F.
    Ferrara, F.
    Gennarelli, C.
    Guerriero, R.
    Migliozzi, M.
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2019, 34 (11): : 1662 - 1670
  • [45] Supporting multi-resolution out-of-core rendering of massive LiDAR point clouds through non-redundant data structures
    Deibe, David
    Amor, Margarita
    Doallo, Ramon
    INTERNATIONAL JOURNAL OF GEOGRAPHICAL INFORMATION SCIENCE, 2019, 33 (03) : 593 - 617
  • [46] Two non-redundant fragments in the N-terminal peptide of human cytosolic methionyl-tRNA synthetase were indispensable for the multi-synthetase complex incorporation and enzyme activity
    He, Ran
    Zu, Li-Dong
    Yao, Peng
    Chen, Xin
    Wang, En-Duo
    BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS, 2009, 1794 (02): : 347 - 354
  • [47] Comparison of fast multi-slice and standard segmented techniques for detection of late gadolinium enhancement in ischemic and non-ischemic cardiomyopathy – a prospective clinical cardiovascular magnetic resonance trial
    Fabian Muehlberg
    Kristin Arnhold
    Simone Fritschi
    Stephanie Funk
    Marcel Prothmann
    Josephine Kermer
    Leonora Zange
    Florian von Knobelsdorff-Brenkenhoff
    Jeanette Schulz-Menger
    Journal of Cardiovascular Magnetic Resonance, 20
  • [48] Comparison of fast multi-slice and standard segmented techniques for detection of late gadolinium enhancement in ischemic and non-ischemic cardiomyopathy - a prospective clinical cardiovascular magnetic resonance trial
    Muehlberg, Fabian
    Arnhold, Kristin
    Fritschi, Simone
    Funk, Stephanie
    Prothmann, Marcel
    Kermer, Josephine
    Zange, Leonora
    von Knobelsdorff-Brenkenhoff, Florian
    Schulz-Menger, Jeanette
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20