Determination of low chlorine concentrations in air using semiconductor chemical sensors

被引:9
|
作者
Belysheva, TV [1 ]
Bogovtseva, LP [1 ]
机构
[1] LY Karpov Phys Chem Res Inst, Moscow 103064, Russia
关键词
D O I
10.1134/S106193480605011X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Comparative studies of electophysical gas-sensitive properties of semiconductor metal oxides (NiO, WO3, and In2O3) in detecting trace concentrations of chlorine in air at 250-300 degrees C were performed. WO3 and ln(2)O(3) film sensors were found to have the best sensitivity, selectivity, and stability. However, WO3 films are characterized by a longer relaxation time (3 min) compared to In2O3 films, for which it is no longer than 30 s. The kinetic and steady-state relative conductivity values of In2O3 films as functions of the chlorine concentration in air fall on the same curve in the range 0.01-0.7 ppm. This suggests that the concentration of chlorine in air can be determined from the initial rates of the variation of the relative conductivity of films, which significantly decreases the time of analysis (from 40 to 5 s at a sensor working temperature of 300 degrees C). Changes in air humidity in the range from 40 to 80% have no effect on the initial rates of the variation of the relative conductivity of In2O3 films under kinetic conditions. The mechanism of the variation of In2O3 film conductivity in detecting chlorine in air was discussed.
引用
收藏
页码:494 / 497
页数:4
相关论文
共 50 条
  • [31] Utilizing a Low-Cost Air Quality Sensor: Assessing Air Pollutant Concentrations and Risks Using Low-Cost Sensors in Selangor, Malaysia
    Zaki Khaslan
    Mohd Shahrul Mohd Nadzir
    Hamimatunnisa Johar
    Zhang Siqi
    Nor Azura Sulong
    Faizal Mohamed
    Shubhankar Majumdar
    Fatin Nur Afiqah Suris
    Nor Syamimi Sufiera Limi Hawari
    Jintu Borah
    Maggie Ooi Chel Gee
    Muhammad Ikram A. Wahab
    Mohd Aftar Abu Bakar
    Noratiqah Mohd Ariff
    Ahmad Zia Ul-Saufie Mohamad Japeri
    Mohd Fadzil Firdzaus Mohd Nor
    Utbah Rabuan
    Sawal Hamid Md Ali
    Brentha Murugan
    Mylene G. Cayetano
    Water, Air, & Soil Pollution, 2024, 235
  • [32] Determination of chlorine concentration using single temperature modulated semiconductor gas sensor
    Wozniak, L.
    Kalinowski, P.
    Jasinski, G.
    Jasinski, P.
    14TH INTERNATIONAL CONFERENCE ON OPTICAL AND ELECTRONIC SENSORS, 2016, 10161
  • [33] CHLORINE-PHOSGENE SYSTEM IN RANGE OF LOW CHLORINE CONCENTRATIONS
    DOBKOWSK.Z
    KRAJEWSK.B
    PRZEMYSL CHEMICZNY, 1967, 46 (11): : 682 - &
  • [34] Determination of oxidative stability of polypropylene using chemical sensors
    Potyrailo, RA
    Wroczynski, RJ
    Morris, WG
    Bradtke, GR
    POLYMER DEGRADATION AND STABILITY, 2004, 83 (03) : 375 - 381
  • [35] Detector tube for the determination of chlorine in air
    Pitschmann, V
    Kobliha, Z
    Halámek, E
    Tusarová, I
    CHEMIA ANALITYCZNA, 2005, 50 (04): : 729 - 734
  • [36] SPECTROPHOTOMETRIC DETERMINATION OF FREE CHLORINE IN AIR
    GABBAY, J
    DAVIDSON, M
    DONAGI, AE
    ANALYST, 1976, 101 (1199) : 128 - 135
  • [37] Determination of chlorine in air using ZnO modified with gallium and indium oxides
    Vinokurova, M. V.
    Vinokurov, A. A.
    Derlyukova, L. E.
    INORGANIC MATERIALS, 2009, 45 (12) : 1399 - 1402
  • [38] Determination of chlorine in air using ZnO modified with gallium and indium oxides
    M. V. Vinokurova
    A. A. Vinokurov
    L. E. Derlyukova
    Inorganic Materials, 2009, 45 : 1399 - 1402
  • [39] Evaluating the performance of low cost chemical sensors for air pollution research
    Lewis, Alastair C.
    Lee, James D.
    Edwards, Peter M.
    Shaw, Marvin D.
    Evans, Mat J.
    Moller, Sarah J.
    Smith, Katie R.
    Buckley, Jack W.
    Ellis, Matthew
    Gillot, Stefan R.
    White, Andrew
    FARADAY DISCUSSIONS, 2016, 189 : 85 - 103
  • [40] USE OF SEMICONDUCTOR SENSORS IN DETERMINATION OF ETHANOL
    GUTH, U
    NEUMANN, B
    GRIMMER, I
    REICHEL, J
    MOBIUS, HH
    GOCKERITZ, D