Thermal comfort in residential buildings - Failure to predict by Standard model

被引:115
|
作者
Becker, R. [1 ]
Paciuk, M. [2 ]
机构
[1] Technion Israel Inst Technol, Fac Civil & Environm Engn, IL-32000 Haifa, Israel
[2] Technion Israel Inst Technol, Natl Bldg Res Inst, IL-32000 Haifa, Israel
关键词
Thermal sensation; Thermal comfort; Predicted mean vote; Dwellings; Field survey; PMV;
D O I
10.1016/j.buildenv.2008.06.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A field study, conducted in 189 dwellings in winter and 205 dwellings in summer, included measurement of hygro-thermal conditions and documentation of occupant responses and behavior patterns. Both samples included both passive and actively space-conditioned dwellings. Predicted mean votes (PMV) computed using Fanger's model yielded significantly lower-than-reported thermal sensation (TS) values, especially for the winter heated and summer air-conditioned groups. The basic model assumption of a proportional relationship between thermal response and thermal load proved to be inadequate. with actual thermal comfort achieved at substantially lower loads than predicted. Survey results also refuted the model's second assumption that symmetrical responses in the negative and positive directions of the scale represent similar comfort levels. Results showed that the model's curve of predicted percentage of dissatisfied (PPD) substantially overestimated the actual percentage of dissatisfied within the partial group of respondents who voted TS > 0 in winter as well as within the partial group of respondents who voted TS < 0 in summer. Analyses of sensitivity to possible survey-related inaccuracy factors (metabolic rate, clothing thermal resistance) did not explain the systematic discrepancies. These discrepancies highlight the role of contextual variables (local climate, expectations, available control) in thermal adaptation in actual settings. Collected data was analyzed statistically to establish baseline data for local standardized thermal and energy calculations. A 90% satisfaction criterion yielded 19.5 degrees C and 26 degrees C as limit values for passive winter and summer design conditions, respectively, while during active conditioning periods, set-point temperatures of 21.5 degrees C and 23 degrees C should be assumed for winter and summer, respectively. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:948 / 960
页数:13
相关论文
共 50 条
  • [21] Fuzzy Evaluation of Thermal Comfort in Naturally Ventilated Residential Buildings in China
    WANG YiNIU TiancaiLIU JiapingXIAO YongqiangSchool of Environmental and Municipal EngineeringXian University of Architecture and TechnologyXianShaanxi ChinaSchool of ArchitectureXian University of Architecture and TechnologyXianShaanxi ChinaSchool of Physical EducationXian University of Architecture and TechnologyXianShaanxi China
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 71 - 74
  • [22] Fuzzy Evaluation of Thermal Comfort in Naturally Ventilated Residential Buildings in China
    WANG Yi1
    2.School of Architecture
    3.School of Physical Education
    湖南大学学报(自然科学版), 2009, (S1) : 71 - 74
  • [23] Thermal comfort and air quality in three mechanically ventilated residential buildings
    Kruger, U
    Kraenzmer, M
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (03): : 181 - 187
  • [24] Evaluation of Passive Cooling and Thermal Comfort in Historical Residential Buildings in Zanzibar
    Liu, Chang
    Xie, Hui
    Ali, Hartha Mohammed
    Liu, Jing
    BUILDINGS, 2022, 12 (12)
  • [25] A field experiment to determine thermal comfort criteria of Malaysians in residential buildings
    Ibrahim, MN
    Hidayat, MS
    ADVANCES IN MALAYSIAN ENERGY RESEARCH 1999, 1999, : 225 - 230
  • [26] Energy Savings in Residential Buildings Based on Adaptive Thermal Comfort Models
    Almeida, Rodrigo
    Georgieva, Petia
    Martins, Nelson
    PATTERN RECOGNITION AND IMAGE ANALYSIS (IBPRIA 2022), 2022, 13256 : 642 - 654
  • [27] A Systematic Review on the Studies of Thermal Comfort in Urban Residential Buildings in China
    Lin, Yaolin
    Chen, Pengju
    Yang, Wei
    Hu, Xiancun
    Tian, Lin
    ENERGIES, 2024, 17 (05)
  • [28] Improving Thermal Comfort in Residential Buildings Using Artificial Immune System
    Zhu, Jiawei
    Lauri, Fabrice
    Koukam, Abderrafiaa
    Hilaire, Vincent
    Simoes, Marcelo Godoy
    2013 IEEE 10TH INTERNATIONAL CONFERENCE ON AND 10TH INTERNATIONAL CONFERENCE ON AUTONOMIC AND TRUSTED COMPUTING (UIC/ATC) UBIQUITOUS INTELLIGENCE AND COMPUTING, 2013, : 194 - 200
  • [29] Fuzzy evaluation of thermal comfort in naturally ventilated residential buildings in China
    Wang, Yi
    Niu, Tian-Cai
    Liu, Jia-Ping
    Xiao, Yong-Qiang
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL.): : 71 - 74
  • [30] Redeveloping industrial buildings for residential use: Energy and thermal comfort aspects
    Valancius, Kestutis
    Motuziene, Violeta
    Paulauskaite, Sabina