Biomimetic compliant lower limb exoskeleton (BioComEx) and its experimental evaluation

被引:27
|
作者
Baser, Ozgur [1 ]
Kizilhan, Hasbi [1 ]
Kilic, Ergin [1 ]
机构
[1] Suleyman Demirel Univ, Dept Mech Engn, Isparta, Turkey
关键词
Lower limb exoskeleton; Variable stiffness actuator; Series elastic actuator; Robot-in-charge; Human-in-charge; ROBOT; ACTUATOR; DESIGN; REHABILITATION; WALKING; JOINT;
D O I
10.1007/s40430-019-1729-4
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Exoskeleton robots are generally used for rehabilitation and load-carrying applications. Stable and flexible walking with minimal energy consumption of the human body is achieved by the compliant operation of the human joints. Essentially, the stiffness of the human ankle joint varies continuously, while the stiffness of the knee and hip joints remains nearly constant during loading phases of the walking cycles. With inspiration from the human leg biomechanics, a new biomimetic compliant lower limb exoskeleton robot (BioComEx) was constructed and its preliminary experimental tests were carried out in this paper. A variable stiffness actuator was developed for the ankle joint of BioComEx, and series elastic actuator designs were employed in the knee and hip joints of the robot. The joint actuators of BioComEx were designed longitudinally in order to be embedded inside of the thigh and shank leg segments for the compactness. Separate force sensors were employed in each segment of the robot for the modularity of the control strategies. Since the exoskeletons can be used for both load-carrying and rehabilitation, the developed robot was tested in both human-in-charge and robot-in-charge modes, respectively. The robot needs to mimic movement of healthy user joints in the human-in-charge mode and maximize the compliance between the user and robot; thus, the interaction forces should be reduced as possible. Hence, a modular closed-loop impedance control algorithm was developed for this mode. On the other hand, in the robot-in-charge mode, the robot joints need to track predefined gait references to make the patient walk. PID position control algorithm was chosen for preliminary test of the robot in this mode. Experimental results show that BioComEx is sufficiently satisfactory for walking applications of healthy and paralyzed users.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] A Lower Limb Exoskeleton with Hybrid Actuation
    Aguilar-Sierra, Hipolito
    Lopez, Ricardo
    Yu, Wen
    Salazar, Sergio
    Lozano, Rogelio
    2014 5TH IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2014, : 695 - 700
  • [32] Transparent Mode for Lower Limb Exoskeleton
    Mendoza-Crespo, R.
    Soto, R.
    Pons, J. L.
    WEARABLE ROBOTICS: CHALLENGES AND TRENDS, 2017, 16 : 421 - 425
  • [33] Design Aspects of Lower Limb Exoskeleton
    Arunkumar S.
    Sarath M.
    Recent Patents on Mechanical Engineering, 2024, 17 (02) : 123 - 131
  • [34] AN INTELLIGENT EXOSKELETON FOR LOWER LIMB REHABILITATION
    Ashrafiuon, Hashem
    Grosh, Kent
    Burke, Kevin J.
    Bommer, Kathleen
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE 2010, VOL 2, PTS A AND B, 2010, : 3 - 9
  • [35] Running with an elastic lower limb exoskeleton
    Cherry, Michael S.
    Kota, Sridhar
    Young, Aaron
    Ferris, Daniel P.
    Journal of Applied Biomechanics, 2016, 32 (03): : 269 - 277
  • [36] RESEARCH ON THE COMPLIANT CONTROL OF ELECTROHYDRAULIC SERVO DRIVE FORCE/POSITION SWITCHING FOR A LOWER LIMB EXOSKELETON ROBOT
    Li, Jianying
    Wei, Aokun
    Yang, Mingyu
    Wang, Yaqian
    TRANSACTIONS OF FAMENA, 2024, 48 (01) : 97 - 116
  • [37] Prototype design, modeling, and experimental research of a novel lower limb powered exoskeleton
    Zhang, Lixun
    Li, Lailu
    Chen, Zhiming
    Song, Da
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (20) : 3766 - 3779
  • [38] Electric Stimulation Feedback System for Lower Limb Exoskeleton - Evaluation of Reaction Time to Abnormal Situation of Lower-limb
    Wang, Xufeng
    Li, Mengze
    Hasegawa, Yasuhisa
    2016 INTERNATIONAL SYMPOSIUM ON MICRO-NANOMECHATRONICS AND HUMAN SCIENCE (MHS), 2016,
  • [39] Experimental Design Verification of a Compliant Shoulder Exoskeleton
    Xu, Kai
    Qiu, Dong
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2013, : 3894 - 3901
  • [40] Design and Performance Evaluation of a Wearable Sensing System for Lower-Limb Exoskeleton
    Yue, Chunfeng
    Lin, Xichuan
    Zhang, Ximing
    Qiu, Jing
    Cheng, Hong
    APPLIED BIONICS AND BIOMECHANICS, 2018, 2018