iStent Trabecular Micro-Bypass Stent Implantation with Cataract Surgery in a Japanese Glaucoma Population

被引:18
|
作者
Nitta, Koji [1 ]
Yamada, Yutaro [1 ]
Morokado, Satomi [1 ]
Sugiyama, Kazuhisa [2 ]
机构
[1] Fukui Ken Saiseikai Hosp, Dept Ophthalmol, Fukui, Fukui, Japan
[2] Kanazawa Univ, Dept Ophthalmol, Kanazawa, Ishikawa, Japan
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
microinvasive glaucoma surgery; MIGS; iStent; trabecular micro-bypass; Japanese; normal-tension glaucoma; OPEN-ANGLE GLAUCOMA; CLEAR CORNEAL PHACOEMULSIFICATION; INTRAOCULAR-PRESSURE CONTROL; CHAMBER LENS IMPLANTATION; ONE-YEAR OUTCOMES; MICROBYPASS STENT; EXTRACTION; PREVALENCE; INJECT; REDUCTION;
D O I
10.2147/OPTH.S274281
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: This study assesses two-year efficacy and safety following implantation of a single trabecular micro-bypass stent (iStent (R)) with concomitant phacoemulsification cataract surgery in Japanese patients with open-angle glaucoma (OAG). Materials and Methods: This retrospective, consecutive case series included eyes that underwent iStent implantation with phacoemulsification and were followed for 24 months postoperative. Efficacy and safety measures included intraocular pressure (TOP), number of glaucoma medications, adverse events, secondary surgeries, visual fields, and endothelial cell counts. Results: Of 73 operated eyes, 53 eyes had 24 months of follow-up and are analyzed. Diagnoses included primary open-angle glaucoma (POAG, n=25), normal-tension glaucoma (NTG, n=16), and pseudoexfoliative glaucoma (PXG, n=12). At 24 months, mean IOP reduced by 18% to 13.6 +/- 3.0 mmHg versus 16.5 +/- 3.4 mmHg preoperatively (p<0.0001), and mean medication number reduced by 81% to 0.37 +/- 0.74 versus 1.96 +/- 0.98 preoperatively (p<0.0001). The percentage of medication-free eyes was 77% versus 0% preoperatively, and 81% of eyes had IOP <15 mmHg versus 42% preoperatively. Results were similarly favorable across glaucoma subtypes (POAG, NTG, PXG). Notably, mean IOP in NTG eyes decreased to 12.8 +/- 1.4 mmHg from 14.4 +/- 3.0 mmHg preoperatively (p=0.03), and medications decreased by 87% to 0.31 +/- 0.70 versus 2.38 +/- 0.72 preoperatively (p<0.0001). At 24 months, 81% of NTG eyes were medication-free (versus 0% preoperatively); 2 NTG eyes (13%) were on >= 2 medications (versus 100% preoperatively). Throughout the follow-up, visual fields and endothelial cell counts remained stable; 1 eye (1.9%) underwent filtration surgery. Discussion: Favorable safety and significant IOP and mediation reductions were achieved through two years following iStent implantation with phacoemulsification in a Japanese population. These gains were achieved across all glaucoma subtypes (including POAG, NTG, PXG). Conclusion: This real-world study supports the viability of iStent implantation to treat Japanese patients with glaucoma and shows that the benefits extend to those with NTG or PXG in addition to POAG.
引用
收藏
页码:3381 / 3391
页数:11
相关论文
共 50 条
  • [31] Initial clinical experience with the trabecular micro-bypass stent in patients with glaucoma
    Detlev Spiegel
    Wolfgang Wetzel
    David S. Haffner
    Richard A. Hill
    Advances in Therapy, 2007, 24 : 161 - 170
  • [32] Initial clinical experience with the trabecular micro-bypass stent in patients with glaucoma
    Spiegel, Detlev
    Wetzel, Wolfgang
    Haffner, David S.
    Hill, Richard A.
    ADVANCES IN THERAPY, 2007, 24 (01) : 161 - 170
  • [33] Mid-Term Evaluation of iStent Inject® Trabecular Micro-Bypass Stent Implantation with or without Phacoemulsification: A Retrospective Study
    Silveira Seixas, Regina Cele
    Balbino, Marcos
    Neto, Alberto Basile
    Almeida Costa, Amanda de Alcantara
    da Silva Jordao, Marcelo Lopes
    Abil Russ, Heloisa Helena
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 4403 - 4413
  • [34] Unplanned Intracanalicular Implantation of a Second-Generation Trabecular Micro-Bypass (iStent inject)
    Gravina, Daniela Marcelo
    Paletta Guedes, Ricardo Augusto
    Paletta Guedes, Vanessa Maria
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (02): : 125 - 125
  • [35] Standalone Implantation of 2-3 Trabecular Micro-Bypass Stents (iStent inject ± iStent) as an Alternative to Trabeculectomy for Moderate-to-Severe Glaucoma
    Paletta Guedes, Ricardo Augusto
    Gravina, Daniela Marcelo
    Paletta Guedes, Vanessa Maria
    Chaoubah, Alfredo
    OPHTHALMOLOGY AND THERAPY, 2022, 11 (01) : 271 - 292
  • [36] Third-Generation Trabecular Micro-Bypass Implantation with Phacoemulsification for Glaucoma
    Vest, Zachary
    Alinaghizadeh, Nadia
    Prendergast, Connor
    OPHTHALMOLOGY AND THERAPY, 2025, 14 (03) : 529 - 539
  • [37] Safety and efficacy of iStent Inject trabecular micro-bypass stents in combination with phacoemulsification for chronic open angle glaucoma associated with cataract
    Cela, D.
    Brasnu, E.
    Hamard, P.
    Baudouin, C.
    Labbe, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (02): : 129 - 136
  • [38] Cataract surgery with trabecular micro-bypass stent implantation in patients with mild-to-moderate open-angle glaucoma and cataract: Two-year follow-up
    Craven, E. Randy
    Katz, L. Jay
    Wells, Jeffrey M.
    Giamporcaro, Jane Ellen
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (08): : 1339 - 1345
  • [39] Trabecular micro-bypass stent implantation during small-incision cataract surgery for open-angle glaucoma or ocular hypertension: Long-term results
    Neuhann, Tobias H.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (12): : 2664 - 2671
  • [40] Implantation of trabecular micro-bypass stent using a novel "landing strip" technique
    Zheng, Cindy X.
    Moster, Marlene R.
    Gogte, Priyanka
    Dai, Yang
    Manzi, Remy S.
    Waisbourd, Michael
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (05) : 738 - 741