iStent Trabecular Micro-Bypass Stent Implantation with Cataract Surgery in a Japanese Glaucoma Population

被引:18
|
作者
Nitta, Koji [1 ]
Yamada, Yutaro [1 ]
Morokado, Satomi [1 ]
Sugiyama, Kazuhisa [2 ]
机构
[1] Fukui Ken Saiseikai Hosp, Dept Ophthalmol, Fukui, Fukui, Japan
[2] Kanazawa Univ, Dept Ophthalmol, Kanazawa, Ishikawa, Japan
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
microinvasive glaucoma surgery; MIGS; iStent; trabecular micro-bypass; Japanese; normal-tension glaucoma; OPEN-ANGLE GLAUCOMA; CLEAR CORNEAL PHACOEMULSIFICATION; INTRAOCULAR-PRESSURE CONTROL; CHAMBER LENS IMPLANTATION; ONE-YEAR OUTCOMES; MICROBYPASS STENT; EXTRACTION; PREVALENCE; INJECT; REDUCTION;
D O I
10.2147/OPTH.S274281
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: This study assesses two-year efficacy and safety following implantation of a single trabecular micro-bypass stent (iStent (R)) with concomitant phacoemulsification cataract surgery in Japanese patients with open-angle glaucoma (OAG). Materials and Methods: This retrospective, consecutive case series included eyes that underwent iStent implantation with phacoemulsification and were followed for 24 months postoperative. Efficacy and safety measures included intraocular pressure (TOP), number of glaucoma medications, adverse events, secondary surgeries, visual fields, and endothelial cell counts. Results: Of 73 operated eyes, 53 eyes had 24 months of follow-up and are analyzed. Diagnoses included primary open-angle glaucoma (POAG, n=25), normal-tension glaucoma (NTG, n=16), and pseudoexfoliative glaucoma (PXG, n=12). At 24 months, mean IOP reduced by 18% to 13.6 +/- 3.0 mmHg versus 16.5 +/- 3.4 mmHg preoperatively (p<0.0001), and mean medication number reduced by 81% to 0.37 +/- 0.74 versus 1.96 +/- 0.98 preoperatively (p<0.0001). The percentage of medication-free eyes was 77% versus 0% preoperatively, and 81% of eyes had IOP <15 mmHg versus 42% preoperatively. Results were similarly favorable across glaucoma subtypes (POAG, NTG, PXG). Notably, mean IOP in NTG eyes decreased to 12.8 +/- 1.4 mmHg from 14.4 +/- 3.0 mmHg preoperatively (p=0.03), and medications decreased by 87% to 0.31 +/- 0.70 versus 2.38 +/- 0.72 preoperatively (p<0.0001). At 24 months, 81% of NTG eyes were medication-free (versus 0% preoperatively); 2 NTG eyes (13%) were on >= 2 medications (versus 100% preoperatively). Throughout the follow-up, visual fields and endothelial cell counts remained stable; 1 eye (1.9%) underwent filtration surgery. Discussion: Favorable safety and significant IOP and mediation reductions were achieved through two years following iStent implantation with phacoemulsification in a Japanese population. These gains were achieved across all glaucoma subtypes (including POAG, NTG, PXG). Conclusion: This real-world study supports the viability of iStent implantation to treat Japanese patients with glaucoma and shows that the benefits extend to those with NTG or PXG in addition to POAG.
引用
收藏
页码:3381 / 3391
页数:11
相关论文
共 50 条
  • [1] Trabecular micro-bypass stent implantation with cataract extraction in pigmentary glaucoma
    Ferguson, Tanner J.
    Ibach, Mitch
    Schweitzer, Justin
    Karpuk, Kayla L.
    Stephens, John D.
    Berdahl, John P.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 48 (01): : 37 - 43
  • [2] iStent trabecular micro-bypass stent for open-angle glaucoma
    Le, Kim
    Saheb, Hady
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 1937 - 1945
  • [3] Coexistent primary open-angle glaucoma and cataract: Preliminary analysis of treatment by cataract surgery and the iStent trabecular micro-bypass stent
    Detlev Spiegel
    Julian García-Feijoó
    Julián García-Sánchez
    Helene Lamielle
    Advances in Therapy, 2008, 25 : 453 - 464
  • [4] Coexistent primary open-angle glaucoma and cataract: Preliminary analysis of treatment by cataract surgery and the iStent trabecular micro-bypass stent
    Spiegel, Detlev
    Garcia-Feijoo, Julian
    Garcia-Sanchez, Julian
    Lamielle, Helene
    ADVANCES IN THERAPY, 2008, 25 (05) : 453 - 464
  • [5] iStent (R): trabecular micro-bypass stent for open-angle glaucoma
    Traverso, Carlo Enrico
    Papadia, Marina
    Scotto, Riccardo
    Bagnis, Alessandro
    EXPERT REVIEW OF OPHTHALMOLOGY, 2010, 5 (04) : 443 - 450
  • [6] Outcomes of Combined iStent Trabecular Micro-Bypass and Cataract Surgery for the Treatment of Open-Angle Glaucoma in a Saudi Population
    Al Habash, Ahmed
    Khan, Omar
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1573 - 1580
  • [7] Implantation of trabecular micro-bypass stent (iStent) using a novel "landing strip" technique
    Zheng, Cindy Xin
    Waisbourd, Michael
    Gogte, Priyanka
    Dai, Yang
    Muhire, Remy Serge Manzi
    Moster, Marlene
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [8] Combined iStent trabecular micro-bypass stent implantation and phacoemulsification for coexistent open-angle glaucoma and cataract: a long-term study
    Arriola-Villalobos, Pedro
    Maria Martinez-de-la-Casa, Jose
    Diaz-Valle, David
    Fernandez-Perez, Cristina
    Garcia-Sanchez, Julian
    Garcia-Feijoo, Julian
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (05) : 645 - 649
  • [9] Randomized Evaluation of the Trabecular Micro-Bypass Stent with Phacoemulsification in Patients with Glaucoma and Cataract
    Samuelson, Thomas W.
    Katz, L. Jay
    Wells, Jeffrey M.
    Duh, Yi-Jing
    Giamporcaro, Jane Ellen
    OPHTHALMOLOGY, 2011, 118 (03) : 459 - 467
  • [10] Two Year Efficacy of Trabecular Micro-Bypass Stent in Patients with Glaucoma and Cataract
    Sayegh, Yoseph
    Baciu, Paul D.
    Vanner, Elizabeth A.
    Maharaj, Arindel S.
    Wellik, Sarah R.
    Kishor, Krishna
    Junk, Anna K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)