Optimization of Heat Exchanger Shell and Tube Design Using Helical Baffle and Coiled Wire Insert Technology

被引:0
|
作者
Syafii, Ahmad [1 ]
Biyanto, Totok R. [1 ]
机构
[1] Inst Teknol Sepuluh Nopember Surabaya, Dept Engn Phys, Surabaya, Indonesia
关键词
D O I
10.1063/1.5095294
中图分类号
O59 [应用物理学];
学科分类号
摘要
Heat Exchanger is a device used to transfer heat between two or more liquids at different temperatures. The purpose of this study is (a) to design efficient shells and tubes using technology to increase heat transfer coefficients at the side of the shell and tube simultaneously, (b) To determine the optimized variables to produce a maximum heat transfer coefficient and a minimal pressure drop, (c) to analyze the effect of applying helical baffle and coiled wire insert technology on overall heat transfer coefficient and pressure drop. On the shell side, segmental technology is modified into helical baffle technology by regulating the tube pitch and distance between baffles. The optimization method used is Genetic algorithm (GA). The variable used for optimization on the shell side is the helical baffle angle (beta) and the distance between the helical baffle (L-bc). Variables used for tube side optimization using coiled wire insert technology are pitch of coiled wire (P) and side length of equilateral triangle (e). The objective function in this study is the overall heat transfer (U). constraint in this study is a pressure drop Delta P that cannot exceed the initial design of the heat exchanger. Modeling of heat E-1-04 was successfully carried out. The modeling obtained has a very small deviation value compared to the initial data sheet HE. Deviation of Overall heat transfer E-1-04 =-0.00%. Deviation Delta P-t E-1-04 =-0.22%. The average deviation of all exchanger Delta P-S = 0.00%. Heat exchanger optimization was successfully carried out. This can be seen from the increase in the overall heat transfer value in all heat exchangers. Increasing U at HE-E-1-04 = 2.08%. Shell pressure drops did not experience significant changes, only 0.01% in all Heat exchangers. But the pressure drops on the tube side decreased. Decreasing Delta P-t at HE-E-1-04 =-11.35%.
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [31] Performance of a shell-and-tube heat exchanger with spiral baffle plates
    Son, YS
    Shin, JY
    KSME INTERNATIONAL JOURNAL, 2001, 15 (11): : 1555 - 1562
  • [32] Performance of a shell-and-tube heat exchanger with spiral baffle plates
    Young-Seok Son
    Jee-Young Shin
    KSME International Journal, 2001, 15 : 1555 - 1562
  • [33] Comparison of heat transfer characteristics of a heat exchanger with straight helical tube and a heat exchanger with coiled flow reverser
    Kazemi-Esfe, Hossein
    Shekhari, Younes
    Omidvar, Pourya
    APPLIED THERMAL ENGINEERING, 2024, 253
  • [34] Heat transfer enhancement in a double-pipe helical heat exchanger using spring wire insert and nanofluid
    Sharaf, Maisa A.
    Marzouk, S. A.
    Aljabr, Ahmad
    Almehmadi, Fahad Awjah
    Kaood, Amr
    Alqaed, Saeed
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (10) : 5017 - 5033
  • [35] The effect of injected air bubble size on the thermal performance of a vertical shell and helical coiled tube heat exchanger
    Hasan S.S.
    Baqir A.Sh.
    Mahood H.B.
    Energy Engineering: Journal of the Association of Energy Engineering, 2021, 118 (06): : 1595 - 1609
  • [36] Effect of air bubble injection on the performance of a horizontal helical shell and coiled tube heat exchanger: An experimental study
    Khorasani, Saleh
    Dadvand, Abdolrahman
    APPLIED THERMAL ENGINEERING, 2017, 111 : 676 - 683
  • [37] Experimental analysis of copper coated helical coiled tube heat exchanger using nanofluid and water
    Ramasubramanian S.
    Baskar S.
    Santhosh R.S.
    Materials Today: Proceedings, 2022, 69 : 804 - 806
  • [38] Theoretical and numerical study of a shell and tube heat exchanger using 22% cut segmental baffle
    Kaleru, Aparna
    Venkatesh, Sriram
    Kumar, Narasimha
    HEAT TRANSFER, 2022, 51 (08) : 7805 - 7821
  • [39] Advantages of coiled flow inverter over shell and tube heat exchanger
    1600, Journal of Chemical and Pharmaceutical Research, 3/668 Malviya Nagar, Jaipur, Rajasthan, India (05):
  • [40] Energy and cost optimization of shell and tube heat exchanger with helical baffles using Kriging metamodel based on MOGA
    Wen, Jian
    Yang, Huizhu
    Jian, Guanping
    Tong, Xin
    Li, Ke
    Wang, Simin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 98 : 29 - 39