Benefits of Point-Spread Function and Time of Flight for PET/CT Image Quality in Relation to the Body Mass Index and Injected Dose

被引:19
|
作者
Akamatsu, Go [1 ]
Mitsumoto, Katsuhiko [1 ]
Ishikawa, Kaori [1 ]
Taniguchi, Takafumi [1 ]
Ohya, Nobuyoshi [2 ]
Baba, Shingo [3 ]
Abe, Koichiro [3 ]
Sasaki, Masayuki [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Fukuoka 8128582, Japan
[2] Kyushu Univ Hosp, Dept Med Technol, Fukuoka, Japan
[3] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Fukuoka 8128582, Japan
基金
日本学术振兴会;
关键词
point-spread function; time-of-flight; image quality; BMI; injected dose; POSITRON-EMISSION-TOMOGRAPHY; LESION DETECTION; F-18-FDG PET/CT; PATIENT WEIGHT; SCAN DURATION; LUNG-CANCER; IMPACT; RECONSTRUCTION; PROTOCOLS; PERFORMANCE;
D O I
10.1097/RLU.0b013e31828da3bd
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The PET image quality of overweight patients and patients who receive low injected doses deteriorates because of increases in statistical noise. The purpose of this study was to investigate the benefits of the point-spread function (PSF) and time-of-flight (TOF) for PET/CT image quality in such patients. Methods: The PET images were reconstructed using the baseline ordered-subsets expectation-maximization algorithm (OSEM), OSEM + PSF, OSEM + TOF, and OSEM + PSF + TOF. In the phantom study, we used a National Electrical Manufacturers Association body phantom with different radioactivity concentrations and analyzed image quality using the coefficient of variance in the background (CVphantom). In the clinical study, we retrospectively studied 39 patients who underwent clinical F-18-FDG PET/CT. The patients were classified into groups based on body mass index and injected dose. Image quality was evaluated using the CV in the liver (CVliver). Results: In the phantom study, PSF and TOF improved the CVphantom, especially in low-activity models. Among all of the reconstructions, the best CVphantom was obtained with OSEM + PSF + TOF. In the clinical study, the CVliver of the low-dose group with OSEM + PSF + TOF was comparable to that of the high-dose group with conventional OSEM. Conclusions: Point-spread function and TOF improved PET/CT image quality for overweight patients who received a lower injected dose. Therefore, the use of PSF and TOF is suggested to maintain the image quality of such patients without extending scanning times. It is greatly beneficial to obtain sufficient image quality for larger patients, especially in delivery institutions where the injection dose cannot be easily increased.
引用
收藏
页码:407 / 412
页数:6
相关论文
共 50 条
  • [31] Impact of Time-of-Flight and Point-Spread-Function in SUV Quantification for Oncological PET
    Prieto, Elena
    Dominguez-Prado, Ines
    Jose Garcia-Velloso, Maria
    Penuelas, Ivan
    Angel Richter, Jose
    Maria Marti-Climent, Josep
    CLINICAL NUCLEAR MEDICINE, 2013, 38 (02) : 103 - 109
  • [32] Optimization of Reconstruction Parameters for Brain PET Studies with Time of Flight and Point Spread Function Modelling
    Prieto, E.
    Marti-Climent, J. M.
    Arbizu, J.
    Ribelles, M. J.
    Sancho, L.
    Quincoces, G.
    Richter, J. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S172 - S172
  • [33] Effect of time-of-flight and point spread function modeling on detectability of myocardial defects in PET
    Schaefferkoetter, Joshua
    Ouyang, Jinsong
    Rakvongthai, Yothin
    Nappi, Carmela
    El Fakhri, Georges
    MEDICAL PHYSICS, 2014, 41 (06)
  • [34] Time-of-flight and point-spread-function allow shorter time acquisitions or lower activity in PET/CT protocols: a phantom study
    Marti-Climent, J. M.
    Prieto, E.
    Garcia-Velloso, M. J.
    Dominguez-Prado, I.
    Rodriguez-Fraile, M.
    Arbizu, J.
    Vigil, C.
    Caicedo, C.
    Richter, J. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S228 - S229
  • [35] Variations of the hepatic SUV in relation to the body mass index in whole body PET-CT studies
    Batalles, S. M.
    Villavicencio, R. L.
    Quaranta, A.
    Burgos, L.
    Trezzo, S.
    Staffieri, R.
    Pezzotto, S. M.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2013, 32 (01): : 26 - 32
  • [36] Impact of point-spread function reconstruction on dynamic and static 18F-DOPA PET/CT quantitative parameters in glioma
    Girard, Antoine
    Francois, Madani
    Chaboub, Nibras
    Le Reste, Pierre-Jean
    Devillers, Anne
    Saint-Jalmes, Herve
    Le Jeune, Florence
    Palard-Novello, Xavier
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (02) : 1397 - 1404
  • [37] Evaluation of image reconstruction algorithms encompassing Time-Of-Flight and Point Spread Function modelling for quantitative cardiac PET: Phantom studies
    Presotto, L.
    Gianolli, L.
    Gilardi, M. C.
    Bettinardi, V.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (02) : 351 - 363
  • [38] Evaluation of image reconstruction algorithms encompassing Time-Of-Flight and Point Spread Function modelling for quantitative cardiac PET: Phantom studies
    L. Presotto
    L. Gianolli
    M. C. Gilardi
    V. Bettinardi
    Journal of Nuclear Cardiology, 2015, 22 : 351 - 363
  • [39] A simple table lookup method for PET/CT partial volume correction using a point-spread function in diagnosing lymph node metastasis
    Sakaguchi, Yuichi
    Mizoguchi, Noriko
    Mitsumoto, Tatsuya
    Mitsumoto, Katsuhiko
    Himuro, Kazuhiko
    Ohya, Nobuyoshi
    Kaneko, Koichiro
    Baba, Shingo
    Abe, Koichiro
    Onizuka, Yoshihiko
    Sasaki, Masayuki
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (08) : 585 - 591
  • [40] A simple table lookup method for PET/CT partial volume correction using a point-spread function in diagnosing lymph node metastasis
    Yuichi Sakaguchi
    Noriko Mizoguchi
    Tatsuya Mitsumoto
    Katsuhiko Mitsumoto
    Kazuhiko Himuro
    Nobuyoshi Ohya
    Koichiro Kaneko
    Shingo Baba
    Koichiro Abe
    Yoshihiko Onizuka
    Masayuki Sasaki
    Annals of Nuclear Medicine, 2010, 24 : 585 - 591