Graphical enhancements to summary receiver operating characteristic plots to facilitate the analysis and reporting of meta-analysis of diagnostic test accuracy data

被引:97
|
作者
Patel, Amit [1 ,2 ]
Cooper, Nicola [2 ,3 ,4 ]
Freeman, Suzanne [2 ,3 ,4 ]
Sutton, Alex [2 ,3 ,4 ]
机构
[1] Univ Birmingham, Coll Med & Dent Sci, Inst Canc & Genom Sci, Canc Res UK Clin Trials Unit, Birmingham, W Midlands, England
[2] Univ Leicester, Dept Hlth Sci, Biostat Res Grp, Leicester, Leics, England
[3] Univ Leicester, NIHR Complex Reviews Support Unit, Leicester, Leics, England
[4] Univ Glasgow, NIHR Complex Reviews Support Unit, Glasgow, Lanark, Scotland
基金
美国国家卫生研究院;
关键词
diagnostic test accuracy; meta-analysis; received operating characteristic curves; TOOL;
D O I
10.1002/jrsm.1439
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Diagnostic test accuracy (DTA) systematic reviews are conducted to summarize evidence on the accuracy of a diagnostic test including a critical evaluation of the primary studies. Where appropriate, the evidence is meta-analyzed to obtain pooled estimates of effectiveness.In this study, we reviewed and critiqued three DTA guidance documents with respect to the graphical presentation of DTA meta-analysis results. All three documents recommended the use of two forms of graphical presentation: (a) forest plots displaying meta-analysis results for sensitivity (ie, the true positive rate) and specificity (ie, true negative rate) separately, and (b) Summary Receiver Operating Characteristic (SROC) curve to provide a global summary of test performance. Two primary shortcomings were identified: (a) lack of incorporation of quality assessment results into the main analysis and; (b) ambiguity with which the contribution of individual studies is represented on SROC curves. In response, two alternative graphical approaches were developed: A quality assessment enhanced SROC plotwhich displays the results from individual studies in the meta-analysis with multiple indicators of quality assessed using QUADAS-2; and A percentage study weights enhanced SROC plotwhich accurately portrays the percentage contribution each study makes to the meta-analysis. The proposed enhanced SROC curves facilitate the exploration of DTA data, leading to a deeper understanding of the primary studies included in a DTA meta-analysis including identifying reasons for between study heterogeneity and why specific study results may be divergent. Both plots can easily be produced in the free online interactive application, MetaDTA ().
引用
收藏
页码:34 / 44
页数:11
相关论文
共 50 条
  • [21] CAST-HSROC: A Web Application for Calculating the Summary Points of Diagnostic Test Accuracy From the Hierarchical Summary Receiver Operating Characteristic Model
    Banno, Masahiro
    Tsujimoto, Yasushi
    Luo, Yan
    Miyakoshi, Chisato
    Kataoka, Yuki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (02)
  • [22] Meta-DiSc 2.0: a web application for meta-analysis of diagnostic test accuracy data
    Plana, Maria N.
    Arevalo-Rodriguez, Ingrid
    Fernandez-Garcia, Silvia
    Soto, Javier
    Fabregate, Martin
    Perez, Teresa
    Roque, Marta
    Zamora, Javier
    BMC MEDICAL RESEARCH METHODOLOGY, 2022, 22 (01)
  • [23] Meta-DiSc 2.0: a web application for meta-analysis of diagnostic test accuracy data
    Maria N. Plana
    Ingrid Arevalo-Rodriguez
    Silvia Fernández-García
    Javier Soto
    Martin Fabregate
    Teresa Pérez
    Marta Roqué
    Javier Zamora
    BMC Medical Research Methodology, 22
  • [25] 'Cross hairs' plots for diagnostic meta-analysis
    Phillips, Bob
    Stewart, Lesley A.
    Sutton, Alex J.
    RESEARCH SYNTHESIS METHODS, 2010, 1 (3-4) : 308 - 315
  • [26] The meta-analysis on summary data
    Maison, Patrick
    RECHERCHE EN SOINS INFIRMIERS, 2010, (101): : 18 - 24
  • [27] Time-dependent summary receiver operating characteristics for meta-analysis of prognostic studies
    Hattori, Satoshi
    Zhou, Xiao-Hua
    STATISTICS IN MEDICINE, 2016, 35 (26) : 4746 - 4763
  • [28] Beta-binomial analysis of variance model for network meta-analysis of diagnostic test accuracy data
    Nyaga, Victoria N.
    Arbyn, Marc
    Aerts, Marc
    STATISTICAL METHODS IN MEDICAL RESEARCH, 2018, 27 (08) : 2554 - 2566
  • [29] Performance of methods for meta-analysis of diagnostic test accuracy with few studies or sparse data
    Takwoingi, Yemisi
    Guo, Boliang
    Riley, Richard D.
    Deeks, Jonathan J.
    STATISTICAL METHODS IN MEDICAL RESEARCH, 2017, 26 (04) : 1896 - 1911
  • [30] Receiver operating characteristic analysis for paired comparison data
    Huo, Ran
    Glickman, Mark E.
    JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES A-STATISTICS IN SOCIETY, 2024,