Robotic Vertebral Puncture System for Percutaneous Vertebroplasty

被引:7
|
作者
Onogi, Shinya [1 ]
Nakajima, Yoshikazu [2 ]
Koyama, Tsuyoshi [3 ]
Tamura, Yuichi [4 ]
Kobayashi, Etsuko [5 ]
Sakuma, Ichiro [5 ]
Sugano, Nobuhiko [6 ]
Yonenobu, Kazuo [3 ]
机构
[1] Tokyo Univ Agr & Technol, Grad Sch Bioapplicat & Syst Engn, Koganei, Tokyo 1838538, Japan
[2] Univ Tokyo, Grad Sch Engn, Dept Bioengn, Tokyo 1138654, Japan
[3] Osaka Minami Hosp, Osaka 5400006, Japan
[4] Toyonaka City Hosp, Osaka 5608565, Japan
[5] Univ Tokyo, Grad Sch Engn, Dept Precis Engn, Tokyo 1138654, Japan
[6] Osaka Univ, Grad Sch Med, Dept Organ Regulat Med, Suita, Osaka 5650871, Japan
关键词
Surgical robotics; Minimally invasive surgery; X-ray-translucent mechanism; Passive failsafe mechanism; HIP-REPLACEMENT;
D O I
10.5405/jmbe.954
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A robotic system with an X-ray-translucent end-effector and a passive failsafe mechanism is proposed for percutaneous vertebroplasty (PVP). The proposed system consists of a puncture robot with five degrees of freedom, a workstation for the navigation system, and an optical tracking device. The end-effector of the robot is partially X-ray translucent to allow the needle insertion process to be monitored by an X-ray fluoroscope. The robot has a passive failsafe mechanism for safety purposes. A needle assembly is attached to the robot by four asymmetric contacting parts supported by four springs. To evaluate the puncture accuracy of the system, puncture tests were conducted on 50 pedicles of five polyurethane phantoms simulating human lumbar vertebrae from L1 to L5. Pre-operative computed tomography (CT) volumes were acquired for the respective phantoms and segmented. Surgical plans were made for the respective pedicles by a surgeon. After the system was placed at the experimental table's side and the phantom was fixed on the table, robot calibration and phantom registration were performed. During the experiments, no needles were found to be protruding from the pedicles. The positioning accuracy measured by the optical tracking device was 0.64 mm root-mean-square (RMS) and 1.09 degrees RMS (error range = 0.1-0.98 mm, 0.96-1.36 degrees). After the tests, postoperative CT volumes of the respective phantoms were acquired and the puncture trajectories were analyzed. The puncture errors between the planned and actual trajectories were 1.66 mm RMs and 1.62 degrees RMS (error range = 0.13-4.21 mm, 0.36-2.73 degrees). The results demonstrate the feasibility of safe and accurate punctures with the proposed system.
引用
收藏
页码:491 / 496
页数:6
相关论文
共 50 条
  • [21] Percutaneous vertebroplasty for osteoporotic vertebral compression fracture
    Buchbinder, Rachelle
    Johnston, Renea V.
    Rischin, Kobi J.
    Homik, Joanne
    Jones, C. Allyson
    Golmohammadi, Kamran
    Kallmes, David F.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2018, (04):
  • [22] Effectiveness of percutaneous vertebroplasty in cases of vertebral metastases
    Nas, O. F.
    Inecikli, M. F.
    Kacar, E.
    Buyukkaya, R.
    Ozkaya, G.
    Aydin, O.
    Erdogan, C.
    Hakyemez, B.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (11) : 1161 - 1168
  • [23] Percutaneous vertebroplasty in painful refractory vertebral hemangiomas
    R. V. Narayana
    Rajesh Pati
    Sibasankar Dalai
    Indian Journal of Orthopaedics, 2014, 48 : 163 - 167
  • [24] Vertebroplasty and kyphoplasty - Percutaneous stabilization of vertebral bodies
    Weisskopf, M
    Ohnsorge, JAK
    Wirtz, DC
    Niethard, FU
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2004, 142 (06): : R59 - R69
  • [25] Percutaneous vertebral augmentation: Vertebroplasty, kyphoplasty and skyphoplasty
    Peh, Wilfred C. G.
    Munk, Peter L.
    Rashid, Faisal
    Gilula, Louis A.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2008, 46 (03) : 611 - +
  • [26] Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fracture
    Bozzo, Anthony
    Bhandari, Mohit
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (10) : 1920 - 1927
  • [27] Complications in Percutaneous Vertebroplasty Associated with Puncture or Cement Leakage
    Clemens Baumann
    Heiko Fuchs
    Jürgen Kiwit
    Kerstin Westphalen
    Johannes Hierholzer
    CardioVascular and Interventional Radiology, 2007, 30 : 161 - 168
  • [28] Unilateral transpedicular percutaneous vertebroplasty using puncture simulation
    Kobayashi K.
    Takizawa K.
    Koyama M.
    Yoshimatsu M.
    Sakaino S.
    Nakajima Y.
    Radiation Medicine, 2006, 24 (3): : 187 - 194
  • [29] Complications in percutaneous vertebroplasty associated with puncture or cement leakage
    Baumann, Clemens
    Fuchs, Heiko
    Kiwit, Jurgen
    Westphalen, Kerstin
    Hierholzer, Johannes
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) : 161 - 168
  • [30] Anatomical and pathological considerations in percutaneous vertebroplasty and kyphoplasty: A reappraisal of the vertebral venous system
    Groen, RJM
    du Toit, DF
    Phillips, FM
    Hoogland, PVJM
    Kuizenga, K
    Coppes, MH
    Muller, CJF
    Grobbelaar, M
    Mattyssen, J
    SPINE, 2004, 29 (13) : 1465 - 1471