Background Endoscopic surgery is developing in various clinical specialties. During ear endoscopic surgery, a surgeon has to hold an endoscope with one hand and operate the surgical instruments with another hand. Therefore, the stability of the surgeon's hand affects the field of surgical view and quality of the surgery considerably. There are few techniques which are used during surgery to stabilize the endoscope. However, no study has evaluated the efficacy of such techniques in detail. This study examined the three dimensional movement of an endoscope to compare and evaluate the effect of various stabilization techniques to reduce the hand tremor while using the endoscope. Methods A non-randomized controlled trial involving 15 medical students was conducted in Tottori University, Japan. Subjects held an endoscope with their non-dominant hand and manipulated it using three different stabilization techniques i.e. with resting the elbow on the table, resting the endoscope on the ear canal, both with the elbow on the table and endoscope on the ear canal. For the control, subjects were made to use the endoscope without any stabilization technique. The endoscopic movement was measured with and without using the stabilization techniques. Results The results obtained in this study indicated that manipulating the endoscope with resting the elbow on the table restrains both vertical (Y-axis) and optical axis (Z-axis) direction of tremor, and manipulating the endoscope by resting it on the ear canal restrains both vertical (Y-axis) and horizontal axis (X-axis) direction while the combined use of both the techniques reduces the endoscope movement in all the three X, Y and Z axes. Conclusion In conclusion, concomitant use of both techniques appears to be clinically beneficial in endoscopic ear surgery.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [31] Three-dimensional endoscopic image analysis
    Kojima, T
    Endo, Y
    Parra-Blanco, HA
    Kirihara, K
    Hattori, T
    Kaminaga, N
    Fujita, R
    GASTROENTEROLOGY, 1999, 116 (04) : A441 - A441
  • [32] Three-dimensional analysis of endoscopic ultrasonography
    Miyamoto, M
    Aoyama, N
    Sakai, S
    Ikemura, T
    Tasaka, K
    Iida, T
    Yoshida, H
    Shirakawa, K
    Futami, S
    Tamura, T
    Honsako, Y
    Morimoto, S
    Nakashima, T
    Ohmoto, A
    Okano, H
    Satonaka, K
    Kasuga, M
    Tamada, F
    GASTROENTEROLOGY, 1997, 112 (04) : A30 - A30
  • [33] Three-Dimensional Motion Analysis of Lumbopelvic Rhythm During Trunk Extension
    Tojima, Michio
    Ogata, Naoshi
    Nakahara, Yasuo
    Haga, Nobuhiko
    JOURNAL OF HUMAN KINETICS, 2016, 50 (01) : 53 - 62
  • [34] Hand motion tracking based on a constraint of three-dimensional continuity
    Inaguma, T
    Saji, H
    Nakatani, H
    JOURNAL OF ELECTRONIC IMAGING, 2005, 14 (01) : 1 - 9
  • [35] Three-dimensional analysis of renal artery bending motion during respiration
    Draney, MT
    Zarins, CK
    Taylor, CA
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (03) : 380 - 386
  • [36] Three-dimensional analysis of renal artery bending motion during respiration
    Draney, MT
    Zarins, CK
    Taylor, CA
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 : 13 - 14
  • [37] A new concept of three-dimensional endoscope for endoscopic surgery
    Muragaki, Y
    Hashizume, M
    Hashimoto, D
    Iseki, H
    Takakura, K
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (11): : 1838 - 1839
  • [38] A new concept of three-dimensional endoscope for endoscopic surgery
    Y. Muragaki
    M. Hashizume
    D. Hashimoto
    H. Iseki
    Kintomo Takakura
    Surgical Endoscopy And Other Interventional Techniques, 2003, 17 : 1838 - 1839
  • [39] Three-Dimensional Endoscopic Endonasal Surgery: A Systematic Review
    Nassimizadeh, Abdul
    Lancer, Hannah
    Hodson, James
    Ahmed, Shahzada
    LARYNGOSCOPE, 2022, 132 (10): : 1895 - 1903
  • [40] Does the angle of the intsruments matter during two handed endoscopic ear surgery?
    Khan, Mubarak Muhamed
    Parab, Sapna Ramkrishna
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2023, 75 (SUPPL 1) : 465 - 469