Dynamic Model-Driven Quantitative and Visual Evaluation of the Aortic Valve from 4D CT

被引:0
|
作者
Ionasec, Razvan Ioan [1 ,2 ]
Georgescu, Bogdan [1 ]
Gassner, Eva [3 ]
Vogt, Sebastian [4 ]
Kutter, Oliver
Scheuering, Michael [4 ]
Navab, Nassir [2 ]
Comaniciu, Dorin [1 ]
机构
[1] Siemens Corp Res, Integrated Data Syst, Princeton, NJ USA
[2] Tech Univ Munich, Comp Aided Med Proc, D-80290 Munich, Germany
[3] Med Univ South Carolina, Dept Radiol, Charleston, WV USA
[4] Siemens Med Solut, Comp Tomography, Forchheim, Germany
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Aortic valve disease is an important cardio-vascular disorder, which affects 2.5% of the global population and often requires elaborate clinical management. Experts agree that visual and quantitative evaluation of the valve, crucial throughout the clinical workflow, is currently limited to 2D imaging which can potentially yield inaccurate measurements. In this paper, we propose a novel approach for morphological and functional quantification of the aortic valve based on a 4D model estimated from computed tomography data. A physiological model of the aortic valve, capable to express large shape variations, is generated using parametric splines together with anatomically-driven topological and geometrical constraints. Recent advances in discriminative learning and incremental searching methods allow rapid estimation of the model parameters from 4D Cardiac CT specifically for each patient. The proposed approach enables precise valve evaluation with model-based dynamic measurements and advanced visualization. Extensive experiments and initial clinical validation demonstrate the efficiency and accuracy of the proposed approach. To the best of our knowledge this is the first time such a patient specific 4D aortic valve model is proposed.
引用
收藏
页码:686 / +
页数:3
相关论文
共 50 条
  • [1] 4D Dynamic Contrast-Enhanced Breast CT: Evaluation of quantitative accuracy
    Pautasso, Juan J.
    Mikerov, Mikhail
    Goris, Liselot
    Michielsen, Koen
    Sechopoulos, Ioannis
    17TH INTERNATIONAL WORKSHOP ON BREAST IMAGING, IWBI 2024, 2024, 13174
  • [2] Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients
    Elattar, Mustafa A.
    Vink, Leon W.
    van Mourik, Martijn S.
    Baan, Jan, Jr.
    van Bavel, Ed T.
    Planken, R. Nils
    Marquering, Henk A.
    PLOS ONE, 2017, 12 (09):
  • [3] Morphological and dynamic analysis of the normal aortic valve with 4D computed tomography
    Fikani, Amine
    Craiem, Damian
    Mousseaux, Elie
    Soulat, Gilles
    Rouchaud, Aymeric
    Boulogne, Cyrille
    Martins, Elie
    Jouan, Jerome
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 65 (04)
  • [4] 4D flow evaluation of abnormal flow patterns with bicuspid aortic valve
    Michael D Hope
    Alison K Meadows
    Thomas A Hope
    Karen G Ordovas
    David Saloner
    Gautham P Reddy
    Marcus T Alley
    Charles B Higgins
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [5] Evaluation of bicuspid aortic valve and aortic coarctation with 4D flow magnetic resonance imaging
    Hope, Michael D.
    Meadows, Alison K.
    Hope, Thomas A.
    Ordovas, Karen G.
    Reddy, Gautham P.
    Alley, Marcus T.
    Higgins, Charles B.
    CIRCULATION, 2008, 117 (21) : 2818 - 2819
  • [6] 4D BIM and Reality Model-Driven Camera Placement Optimization for Construction Monitoring
    Houng, Seau Chen
    Pal, Aritra
    Lin, Jacob J.
    JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT, 2024, 150 (06)
  • [7] Evaluation of the impact of 4D reconstruction algorithms in quantitative dynamic SPECT
    Narayanan, MV
    Licho, R
    Farncombe, TH
    King, MA
    Pretorius, PH
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1023 - 1026
  • [8] Assessment of a quantitative metric for 4D CT artifact evaluation by observer consensus
    Castillo, Sarah J.
    Castillo, Richard
    Balter, Peter
    Pan, Tinsu
    Ibbott, Geoffrey
    Hobbs, Brian
    Yuan, Ying
    Guerrero, Thomas
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 190 - 201
  • [9] Quantitative evaluation of aortic valve regurgitation in 4D flow cardiac magnetic resonance: at which level should we measure?
    Polacin, Malgorzata
    Geiger, Julia
    Burkhardt, Barbara
    Callaghan, Fraser M.
    Valsangiacomo, Emanuela
    Kellenberger, Christian
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [10] Quantitative evaluation of aortic valve regurgitation in 4D flow cardiac magnetic resonance: at which level should we measure?
    Malgorzata Polacin
    Julia Geiger
    Barbara Burkhardt
    Fraser M. Callaghan
    Emanuela Valsangiacomo
    Christian Kellenberger
    BMC Medical Imaging, 22