Accuracy of real-time PCR, Gram stain and culture for Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae meningitis diagnosis

被引:88
|
作者
Wu, Henry M. [1 ]
Cordeiro, Soraia M. [2 ]
Harcourt, Brian H. [1 ]
Carvalho, Maria da Gloria S. [1 ]
Azevedo, Jailton [2 ]
Oliveira, Tainara Q. [3 ]
Leite, Mariela C. [3 ]
Salgado, Katia [2 ]
Reis, Mitermayer G. [2 ]
Plikaytis, Brian D. [1 ]
Clark, Thomas A. [1 ]
Mayer, Leonard W. [1 ]
Ko, Albert I. [2 ,4 ]
Martin, Stacey W. [1 ]
Reis, Joice N. [2 ,3 ]
机构
[1] CDC, Div Bacterial Dis, Natl Ctr Immunizat & Resp Dis, Atlanta, GA 30333 USA
[2] Fundacao Oswaldo Cruz, BR-40296710 Salvador, BA, Brazil
[3] Univ Fed Bahia, Salvador, BA, Brazil
[4] Cornell Univ, Weill Med Coll, New York, NY 10065 USA
关键词
Bacterial meningitis; Diagnostic test evaluation; Real-time PCR; Streptococcus pneumoniae Neisseria meningitidis; Haemophilus influenzae; POLYMERASE-CHAIN-REACTION; BACTERIAL-MENINGITIS; MENINGOCOCCAL MENINGITIS; CEREBROSPINAL-FLUID; DISEASE; AMPLIFICATION; EPIDEMIOLOGY; FEATURES; ADULTS; TESTS;
D O I
10.1186/1471-2334-13-26
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Although cerebrospinal fluid (CSF) culture is the diagnostic reference standard for bacterial meningitis, its sensitivity is limited, particularly when antibiotics were previously administered. CSF Gram staining and real-time PCR are theoretically less affected by antibiotics; however, it is difficult to evaluate these tests with an imperfect reference standard. Methods and findings: CSF from patients with suspected meningitis from Salvador, Brazil were tested with culture, Gram stain, and real-time PCR using S. pneumoniae, N. meningitidis, and H. influenzae specific primers and probes. An antibiotic detection disk bioassay was used to test for the presence of antibiotic activity in CSF. The diagnostic accuracy of tests were evaluated using multiple methods, including direct evaluation of Gram stain and real-time PCR against CSF culture, evaluation of real-time PCR against a composite reference standard, and latent class analysis modeling to evaluate all three tests simultaneously. Results: Among 451 CSF specimens, 80 (17.7%) had culture isolation of one of the three pathogens (40 S. pneumoniae, 36 N. meningitidis, and 4 H. influenzae), and 113 (25.1%) were real-time PCR positive (51 S. pneumoniae, 57 N. meningitidis, and 5 H. influenzae). Compared to culture, real-time PCR sensitivity and specificity were 95.0% and 90.0%, respectively. In a latent class analysis model, the sensitivity and specificity estimates were: culture, 81.3% and 99.7%; Gram stain, 98.2% and 98.7%; and real-time PCR, 95.7% and 94.3%, respectively. Gram stain and real-time PCR sensitivity did not change significantly when there was antibiotic activity in the CSF. Conclusion: Real-time PCR and Gram stain were highly accurate in diagnosing meningitis caused by S. pneumoniae, N. meningitidis, and H. influenzae, though there were few cases of H. influenzae. Furthermore, real-time PCR and Gram staining were less affected by antibiotic presence and might be useful when antibiotics were previously administered. Gram staining, which is inexpensive and commonly available, should be encouraged in all clinical settings.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Accuracy of real-time PCR, Gram stain and culture for Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae meningitis diagnosis
    Henry M Wu
    Soraia M Cordeiro
    Brian H Harcourt
    Maria da Gloria S Carvalho
    Jailton Azevedo
    Tainara Q Oliveira
    Mariela C Leite
    Katia Salgado
    Mitermayer G Reis
    Brian D Plikaytis
    Thomas A Clark
    Leonard W Mayer
    Albert I Ko
    Stacey W Martin
    Joice N Reis
    [J]. BMC Infectious Diseases, 13
  • [2] Diagnosis of bacterial meningitis caused by Streptococcus pneumoniae, Neisseria meningitidis, and Haemophilus influenzae using a multiplex real-time PCR technique
    Noemi Carnalla-Barajas, Maria
    Soto-Nogueron, Araceli
    Martinez-Medina, Lucila
    Elizabeth Olvera-Herrera, Maria
    Luis Mosqueda-Gomez, Juan
    Rodriguez-Cortez, Patricia
    Morfin-Otero, Rayo
    Rodriguez-Noriega, Eduardo
    Luevanos-Velazquez, Antonio
    Merlo-Palomera, Mariana
    Esparza-Ahumada, Sergio
    Marquez-Diaz, Francisco
    Mercedes Alpuche-Aranda, Celia
    Echaniz-Aviles, Gabriela
    [J]. BRAZILIAN JOURNAL OF MICROBIOLOGY, 2022, 53 (04) : 1951 - 1958
  • [3] Diagnosis of bacterial meningitis caused by Streptococcus pneumoniae, Neisseria meningitidis, and Haemophilus influenzae using a multiplex real-time PCR technique
    María Noemí Carnalla-Barajas
    Araceli Soto-Noguerón
    Lucila Martínez-Medina
    Maria Elizabeth Olvera-Herrera
    Juan Luis Mosqueda-Gómez
    Patricia Rodríguez-Cortez
    Rayo Morfin-Otero
    Eduardo Rodriguez-Noriega
    Antonio Luévanos-Velázquez
    Mariana Merlo-Palomera
    Sergio Esparza-Ahumada
    Francisco Márquez-Díaz
    Celia Mercedes Alpuche-Aranda
    Gabriela Echaniz-Aviles
    [J]. Brazilian Journal of Microbiology, 2022, 53 : 1951 - 1958
  • [4] Simultaneous detection of Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae in suspected cases of meningitis and septicemia using real-time PCR
    Corless, CE
    Guiver, M
    Borrow, R
    Edwards-Jones, V
    Fox, AJ
    Kaczmarski, EB
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (04) : 1553 - 1558
  • [5] Real-time PCR detection of Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae DNA in clinical specimens
    Vackova, Z.
    Lzicarova, D.
    Stock, N. K.
    Kozakova, J.
    [J]. EPIDEMIOLOGIE MIKROBIOLOGIE IMUNOLOGIE, 2015, 64 (04): : 222 - 230
  • [6] Incidence and prognosis of meningitis due to Haemophilus influenzae, Streptococcus pneumoniae and Neisseria meningitidis in Sweden
    Berg, S
    Trollfors, B
    Claesson, BA
    Alestig, K
    Gothefors, L
    Hugosson, S
    Lindquist, L
    Olcen, P
    Romanus, V
    Strangert, K
    [J]. SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 1996, 28 (03) : 247 - 252
  • [7] Evaluation of nested PCR method for diagnosis of meningitis due to Neisseria meningitidis and Haemophilus influenzae
    Bonab, Zahra Hojjati
    Farajnia, Safar
    Ghotaslou, Reza
    Nikkhah, Elhameh
    [J]. TURKISH JOURNAL OF BIOLOGY, 2012, 36 (06) : 727 - 731
  • [8] Triplex real-time PCR assay for the detection of Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae directly from clinical specimens without extraction of DNA
    Ouattara, Mahamoudou
    Whaley, Melissa J.
    Jenkins, Laurel T.
    Schwartz, Stephanie B.
    Traore, Rasmata Ouedraogo
    Diana, Seydou
    Collard, Jean-Marc
    Sacchi, Claudio T.
    Wang, Xin
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 93 (03) : 188 - 190
  • [9] Multiplex quantitative PCR for detection of lower respiratory tract infection and meningitis caused by Streptococcus pneumoniae, Haemophilus influenzae and Neisseria meningitidis
    Guma MK Abdeldaim
    Kristoffer Strålin
    Jens Korsgaard
    Jonas Blomberg
    Christina Welinder-Olsson
    Björn Herrmann
    [J]. BMC Microbiology, 10
  • [10] Multiplex quantitative PCR for detection of lower respiratory tract infection and meningitis caused by Streptococcus pneumoniae, Haemophilus influenzae and Neisseria meningitidis
    Abdeldaim, Guma M. K.
    Stralin, Kristoffer
    Korsgaard, Jens
    Blomberg, Jonas
    Welinder-Olsson, Christina
    Herrmann, Bjorn
    [J]. BMC MICROBIOLOGY, 2010, 10