Experimental and numerical investigation of the operating performance of air-to-air membrane enthalpy exchangers

被引:3
|
作者
Albdoor, Ahmed K. [1 ,2 ]
Ma, Zhenjun [1 ]
Al-Ghazzawi, Fatimah [2 ,3 ,4 ]
Liu, Jingjing [1 ]
Awan, Muhammed B. [1 ]
机构
[1] Univ Wollongong, Sustainable Bldg Res Ctr SBRC, Wollongong, NSW 2522, Australia
[2] Southern Tech Univ, Al Nasiriyah Tech Inst, Thi Qar 64001, Iraq
[3] Univ Wollongong, Intelligent Polymer Res Inst, Wollongong, NSW 2522, Australia
[4] Univ Wollongong, ARC Ctr Electromat Sci, Wollongong, NSW 2522, Australia
关键词
Energy recovery; Membrane enthalpy exchanger; Performance evaluation; Heat and moisture transfer; Mathematical modelling; MASS-TRANSFER; HEAT; PLATE; VENTILATION; SYSTEM;
D O I
10.1016/j.seta.2021.101722
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study examined the impacts of major operating parameters on the performance of a cross flow membrane enthalpy exchanger (MEE) with porous membranes. A lab-scale setup was developed to conduct the experiments based on the test matrix designed with various operating conditions for both heating and cooling operations. The MEE core was made of porous membranes. A mathematical model was developed to predict the transferred heat and moisture fluxes through the membrane. The model implemented a variable moisture diffusivity of the membrane that varied with local air conditions. It was found that the sensible, latent, and total effectiveness of the MEE significantly improved when reducing the airflow rate. In the cooling mode, outdoor air temperature and humidity had a positive influence on the MEE effectiveness, while they showed a negative impact on the heating operations. However, the influences of outdoor conditions on the sensible, latent, and total effectiveness of the MEE were rather insignificant as compared to that of the airflow rate. On the other hand, both airflow rate and outdoor conditions showed significant effects on thermal resistance and total energy recovered for both operating modes. The findings obtained can be used to facilitate optimal design of such devices.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] A comprehensive numerical investigation of the effects of inlet operating conditions on the performance of 3-fluid liquid-to-air membrane energy exchangers
    Zabihi A.
    Pourmahmoud N.
    Journal of Computational and Applied Research in Mechanical Engineering, 2024, 13 (02): : 137 - 156
  • [32] Air conditioning system with enthalpy recovery for space heating and air humidification: An experimental and numerical investigation
    Niemann, Peter
    Schmitz, Gerhard
    ENERGY, 2020, 213 (213)
  • [33] Experimental investigation and modeling of a dual-core air-to-air exchanger
    Souifi, Haifa
    Bouslimani, Yassine
    Ghribi, Mohsen
    Colin, Serge
    ENERGY AND BUILDINGS, 2021, 231
  • [34] AIR-TO-AIR HEAT-EXCHANGERS FOR HOUSES - SCHURCLIFF,WA
    不详
    ELECTRICAL WORLD, 1983, 197 (02): : 121 - 121
  • [35] Experimental investigation on the performance of an air-to-air energy recovery for building applications in hot-humid climate
    Zafirah, M. F.
    Mardiana, A.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2016, 10 (01) : 1857 - 1864
  • [36] Numerical investigation of condensation characteristics of a moist air-to-air plate-fin heat exchanger and experimental validation
    Lei, Xiangshu
    Lin, Zibo
    Wang, Ying
    Li, Xinyang
    Liu, Yingwen
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 191
  • [37] Experimental investigation on the heat and water transfer enhancement in a membrane-based air-to-air humidifier at insulation condition
    Ghaedamini, M.
    Baharlou-Houreh, N.
    Afshari, E.
    Shokouhmand, H.
    Jahantigh, N.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (38) : 17010 - 17021
  • [38] Numerical simulation of operating performance of heat exchangers in a residential split air-conditioner
    Su, Shunyu
    Tian, Tian
    Chen, Jian
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3913 - 3918
  • [39] A POLYMERIC APPROACH TO COUNTERACT FROSTING IN AIR-TO-AIR HEAT-EXCHANGERS
    OSTIN, R
    JOHANNESSON, G
    HEAT RECOVERY SYSTEMS & CHP, 1991, 11 (05): : 415 - 421
  • [40] Energetic analysis of an air handling unit combined with enthalpy air-to-air heat exchanger
    Kalbasi, Rasool
    Ruhani, Behrooz
    Rostami, Sara