Precise Limb Tourniquet Arterial Occlusion Pressure Determination using Real-Time Ultrasonography and a Capacitive-Based Force Sensor

被引:1
|
作者
Wood, Jeffrey N. [1 ,2 ]
Krippendorf, Benjamin S. [2 ]
Blakeney, Craig A. [1 ,2 ]
Kummer, Tobias [2 ]
Hooke, Alexander W. [3 ]
Mullan, Aidan F. [4 ]
Sztajnkrycer, Matthew D. [1 ,2 ]
机构
[1] Mayo Clin, Div Prehosp Care, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Emergency Med, 200 First St SW, Rochester, MN 55905 USA
[3] Mayo Clin, Biomech Res Lab, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Hlth Sci Res, Rochester, MN 55905 USA
关键词
force; hemorrhage; pressure; tourniquet; windlass; PREHOSPITAL TOURNIQUET; HEMORRHAGE; TRAUMA; DEATH;
D O I
10.1017/S1049023X2200142X
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Hemorrhage control prior to shock onset is increasingly recognized as a time-critical intervention. Although tourniquets (TQs) have been demonstrated to save lives, less is known about the physiologic parameters underlying successful TQ application beyond palpation of distal pulses. The current study directly visualized distal arterial occlusion via ultrasonography and measured associated pressure and contact force. Methods: Fifteen tactical officers participated as live models for the study. Arterial occlusion was performed using a standard adult blood pressure (BP) cuff and a Combat Application Tourniquet Generation 7 (CAT7) TQ, applied sequentially to the left mid-bicep. Arterial flow cessation was determined by radial artery palpation and brachial artery pulsed wave doppler ultrasound (US) evaluation. Steady state maximal generated force was measured using a thin-film force sensor. Results: The mean (95% CI) systolic blood pressure (SBP) required to occlude palpable distal pulse was 112.9mmHg (109-117); contact force was 23.8N [Newton] (22.0-25.6). Arterial flow was visible via US in 100% of subjects despite lack of palpable pulse. The mean (95% CI) SBP and contact force to eliminate US flow were 132mmHg (127-137) and 27.7N (25.1-30.3). The mean (95% CI) number of windlass turns to eliminate a palpable pulse was 1.3 (1.0-1.6) while 1.6 (1.2-1.9) turns were required to eliminate US flow. Conclusions: Loss of distal radial pulse does not indicate lack of arterial flow distal to upper extremity TQ. On average, an additional one-quarter windlass turn was required to eliminate distal flow. Blood pressure and force measurements derived in this study may provide data to guide future TQ designs and inexpensive, physiologically accurate TQ training models.
引用
收藏
页码:772 / 777
页数:6
相关论文
共 50 条
  • [21] Real-time in vitro determination of copper ions with a nanocapillary-based sensor
    Timoshenko, Roman
    Vaneev, Alexander
    Savin, Nikita
    Chmelyuk, Nelly
    Krasnovskaya, Olga
    Savchenko, Alexander
    Klyachko, Natalia
    Majouga, Alexander
    Gorelkin, Peter
    Erofeev, Alexander
    Korchev, Yuri
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2021, 50 (SUPPL 1): : 201 - 201
  • [22] Continuous and Real-Time Measurement of Plant Water Potential Using an AAO-Based Capacitive Humidity Sensor for Irrigation Control
    Han, Sanghoon
    Kim, Woojoong
    Lee, Hyun Jae
    Joyce, Robin
    Lee, Junghoon
    ACS APPLIED ELECTRONIC MATERIALS, 2022, 4 (12) : 5922 - 5932
  • [23] Real-time gait event detection for lower limb amputees using a single wearable sensor
    Maqbool, H. F.
    Husman, M. A. B.
    Awad, M. I.
    Abouhossein, A.
    Mehryar, P.
    Iqbal, N.
    Dehghani-Sanij, A. A.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 5067 - 5070
  • [24] Real-time precise orbit determination for BDS satellites using the square root information filter
    Xiaolei Dai
    Yidong Lou
    Zhiqiang Dai
    Yun Qing
    Min Li
    Chuang Shi
    GPS Solutions, 2019, 23
  • [25] Real-time precise orbit determination for BDS satellites using the square root information filter
    Dai, Xiaolei
    Lou, Yidong
    Dai, Zhiqiang
    Qing, Yun
    Li, Min
    Shi, Chuang
    GPS SOLUTIONS, 2019, 23 (02)
  • [26] Precise Real-Time Relative Orbit Determination for Large-Baseline Formations Using GNSS
    Giralo, Vincent
    D'Amico, Simone
    PROCEEDINGS OF THE 2021 INTERNATIONAL TECHNICAL MEETING OF THE INSTITUTE OF NAVIGATION, 2021, : 366 - 384
  • [27] A review of real-time multi-GNSS precise orbit determination based on the filter method
    Lou, Yidong
    Dai, Xiaolei
    Gong, Xiaopeng
    Li, Chenglong
    Qing, Yun
    Liu, Yang
    Peng, Yaquan
    Gu, Shengfeng
    SATELLITE NAVIGATION, 2022, 3 (01):
  • [28] A review of real-time multi-GNSS precise orbit determination based on the filter method
    Yidong Lou
    Xiaolei Dai
    Xiaopeng Gong
    Chenglong Li
    Yun Qing
    Yang Liu
    Yaquan Peng
    Shengfeng Gu
    Satellite Navigation, 3
  • [29] A Real-time Temperature Compensation Algorithm for a Force-rebalanced MEMS Capacitive Accelerometer Based on Resonant Frequency
    Du, Jiehui
    Guo, Yixuan
    Lin, Yiyu
    Zheng, Xudong
    Jin, Zhonghe
    2017 IEEE 12TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2017, : 214 - 217
  • [30] Feasibility of Real-Time Conditional Sacral Neuromodulation Using Wireless Bladder Pressure Sensor
    Majerus, Steve J. A.
    Offutt, Sarah J.
    Brink, Thaddeus S.
    Vasoli, Vincent
    McAdams, Ian
    Damaser, Margot S.
    Zirpel, Lance
    IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2021, 29 : 2067 - 2075