Experimental investigation of the heat transfer performance of an oscillating heat pipe with LiCl salt solution

被引:7
|
作者
Wang, Peng [1 ,2 ]
Cui, Xiaoyu [1 ,2 ]
Weng, Jianhua [3 ]
Cai, Ziqiu [1 ,2 ]
Cai, Ren [3 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, 516 Jungong Rd, Shanghai 200093, Peoples R China
[2] Shanghai Key Lab Multiphase Flow & Heat Transfer, Shanghai 200093, Peoples R China
[3] Shanghai Univ Elect Power, Coll Energy & Mech Engn, Shanghai 200090, Peoples R China
关键词
Oscillating heat pipe LiCl salt solution; Hygroscopicity Phase change Thermal resistance; THERMAL PERFORMANCE; WORKING FLUIDS; START-UP; THERMODYNAMICS; SURFACTANT;
D O I
10.1016/j.ijheatmasstransfer.2020.120033
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer performance of oscillating heat pipes (OHPs) with LiCl solution was investigated experimentally at the concentration of 5wt%, 10wt% and 15wt% with the heat input ranging from 10 to 100 W and the filling ratio (FR) of 45%, 55%, 62%, 70%, 80%, and 90%. OHP with different concentrations of LiCl solution can improve the heat transfer performance compared with deionized water (DW) in most conditions, because of the combined positive effects of bubble characteristics, absorption and generation mechanism, two-phase flow, mass transfer, and other behaviors caused by hygroscopicity of LiCl solution. At an appropriate filling ratio (62% and 70%), the addition of LiCl in DW reduces the thermal resistance of OHP. The thermal resistance of a 62% volume of 10wt% LiCl solution reduces up to 61% compared with DW. At low filling ratio (45% and 55%), LiCl solution can reduce the temperature of the evaporation section and improve the anti-dry-out ability; simultaneously, the higher the concentration, the better the effect. It is due to the low water activity and the characteristics of bubble generation and growth in LiCl solution. At increased filling ratio (80% and 90%), the reduction of the gas phase space inside the OHP and the slowing down of the working fluid make the effect of adding LiCl less on the heat transfer performance, 5wt% LiCl solution performs better than the other concentrations. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Experimental study of flow state and heat transfer performance of closed-loop oscillating heat pipe
    Liu, Xiang-Dong
    Shi, Kai
    Guo, Yu-Han
    Lu, Jin-Li
    Wang, Shu-Juan
    Hao, Ying-Li
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (10): : 1735 - 1738
  • [42] Experimental investigation and influence of filling ratio on heat transfer performance of a pulsating heat pipe
    Rudresha, S.
    Babu, E. R.
    Thejaraju, R.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 38
  • [43] Experimental Investigation of Heat Transfer Performance of A Miniature Loop Heat Pipe with Flat Evaporator
    Zhang, Xianfeng
    Wang, Shuangfeng
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 3806 - 3809
  • [44] Experimental Investigation of the Heat transfer Performance of a Newly Designed Heat Pipe Cold Plate
    Ma, Zheshu
    Yao, Shouguang
    PROCEEDINGS OF THE 6TH IASME/WSEAS INTERNATIONAL CONFERENCE ON HEAT TRANSFER, THERMAL ENGINEERING AND ENVIRONMENT (HTE'08), PTS I AND II: NEW ASPECTS OF HEAT TRANSFER, THERMAL ENGINEERING AND ENVIRONMENT, 2008, : 381 - +
  • [45] Flower Shape Oscillating Heat Pipe - A novel type of oscillating heat pipe in a rotary system of coordinates - An experimental investigation
    Czajkowski, Cezary
    Nowak, Andrzej, I
    Pietrowicz, Slawomir
    APPLIED THERMAL ENGINEERING, 2020, 179 (179)
  • [46] Experimental investigation of transient heat transfer characteristics of a heat pipe
    Sundaram, A. Shanmuga
    Velraj, R.
    Suganya, G.
    International Journal of Heat and Technology, 2009, 27 (01) : 29 - 35
  • [47] A conjugate heat transfer model of oscillating heat pipe dynamics, performance, and dryout
    Li, Yuxuan
    Eldredge, Jeff D.
    Lavine, Adrienne S.
    Fisher, Timothy S.
    Drolen, Bruce L.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 227
  • [48] Performance of circular Oscillating Heat Pipe for highly adaptable heat transfer layout
    Okazaki, Shun
    Fuke, Hideyuki
    Ogawa, Hiroyuki
    APPLIED THERMAL ENGINEERING, 2021, 198
  • [49] COPPER OXIDE (CUO) EFFECT ON HEAT TRANSFER PERFORMANCE IN AN OSCILLATING HEAT PIPE
    Ji, Yulong
    Xu, Chen
    Ma, Hongbin
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2012, VOL 2, 2012, : 361 - 364
  • [50] Experimental Investigation of a Three-Phase Oscillating Heat Pipe
    Hao, Tingting
    Ma, Hongbin
    Ma, Xuehu
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2019, 11 (06)