Correlation of ultrasound bone velocity with dual-energy x-ray bone absorptiometry in rat bone specimens

被引:13
|
作者
Amo, C [1 ]
Revilla, M [1 ]
Hernandez, ER [1 ]
GonzalezRiola, J [1 ]
Villa, LF [1 ]
Seco, C [1 ]
Rico, H [1 ]
机构
[1] UNIV ALCALA DE HENARES, DEPT MED, E-28801 MADRID, SPAIN
关键词
bone densitometry; ultrasound bone mass; bone ultrasound transmission; velocity; rats; experimental studies;
D O I
10.1097/00004424-199602000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. To investigate bone mass measurements by ultrasound bone velocity (UBV) in bone specimens obtained from experimental animals. METHODS. The authors made UBV measurements in 40 femurs and tibias dissected from Sprague-Dawley rats (14 weeks-old, mean weight 290 g) and compared them with bone densitometric measurements made on the same material using dual-energy x-ray absorptiometry (DXA). RESULTS. The coefficient of variation for UBV measurements, based on values obtained in five femurs and five tibias at different times, was 0.2% and 03% respectively. Regression studies yielded a correlation between UBV and bone mineral density in femur of r = 0.87 (P < 0.0001) and with bone mineral content of r = 0.65 (P < 0.0001); in the tibia similar levels of significance were obtained. The correlation between femur weight and UBV was r = 0.51 (P < 0.0005) and with bone mineral content it was r = 0.79 (P < 0.0001). Partial correlation between UBV and femur bone mineral density, with respect to bone weight, was r = 0.68 (P < 0.001), and with femur bone mineral content was r = 0.71 (P < 0.0001). In the tibia measurements were similarly significant. CONCLUSIONS. Measurements of bone mass made with ultrasound transmission velocity are precise correlate well with DXA measurements.
引用
收藏
页码:114 / 117
页数:4
相关论文
共 50 条
  • [41] CHANGES IN BONE MINERALIZATION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY (DXA) DURING INFANCY
    KOO, W
    WALTERS, J
    CARLSON, SE
    PEDIATRIC RESEARCH, 1995, 37 (04) : A64 - A64
  • [42] The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals
    Fuller, Joel T.
    Archer, Jane
    Buckley, Jonathan D.
    Tsiros, Margarita D.
    Thewlis, Dominic
    SKELETAL RADIOLOGY, 2016, 45 (01) : 135 - 140
  • [43] Bone mineral density measurements in otosclerosis using dual-energy X-ray absorptiometry
    Tonuk, S. B.
    Koybasi, S.
    Bicer, Y. O.
    Alkan Temel, S.
    CLINICAL OTOLARYNGOLOGY, 2016, 41 (02) : 149 - 153
  • [44] Bone Density Measured by Dual-Energy X-ray Absorptiometry in Healthy Kuwaiti Women
    G. Dougherty
    N. Al-Marzouk
    Calcified Tissue International, 2001, 68 : 225 - 229
  • [45] Relationship between bone strength and dual-energy X-ray absorptiometry measurements in pigs
    Nielsen, D. H.
    McEvoy, F. J.
    Madsen, M. T.
    Jensen, J. B.
    Svalastoga, E.
    JOURNAL OF ANIMAL SCIENCE, 2007, 85 (03) : 667 - 672
  • [46] ESTIMATES OF BONE STRENGTH WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY IN SIMULATED LYTIC LESIONS
    ROBERTSON, DD
    CHAN, BW
    BECK, TJ
    SCOTT, WW
    CURTIS, MJ
    FISHMAN, EK
    RADIOLOGY, 1992, 185 : 292 - 292
  • [47] DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR THE MEASUREMENT OF BONE AND SOFT-TISSUE COMPOSITION
    TOTHILL, P
    CLINICAL NUTRITION, 1995, 14 (05) : 263 - 268
  • [48] Total body bone measurements in spinal osteoporosis by dual-energy X-ray absorptiometry
    Revilla, RM
    Hernandez, ER
    Villa, LF
    Seco, C
    SanchezAtrio, A
    Rico, H
    CALCIFIED TISSUE INTERNATIONAL, 1997, 61 (01) : 44 - 47
  • [49] Trabecular alveolar bone in the human mandible:: A dual-energy x-ray absorptiometry study
    Choël, L
    Duboeuf, F
    Bourgeois, D
    Briguet, A
    Lissac, M
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2003, 95 (03): : 364 - 370
  • [50] Fundamentals and pitfalls of bone densitometry using dual-energy X-ray absorptiometry (DXA)
    Watts, NB
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 (11) : 847 - 854