Correlation of ultrasound bone velocity with dual-energy x-ray bone absorptiometry in rat bone specimens

被引:13
|
作者
Amo, C [1 ]
Revilla, M [1 ]
Hernandez, ER [1 ]
GonzalezRiola, J [1 ]
Villa, LF [1 ]
Seco, C [1 ]
Rico, H [1 ]
机构
[1] UNIV ALCALA DE HENARES, DEPT MED, E-28801 MADRID, SPAIN
关键词
bone densitometry; ultrasound bone mass; bone ultrasound transmission; velocity; rats; experimental studies;
D O I
10.1097/00004424-199602000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. To investigate bone mass measurements by ultrasound bone velocity (UBV) in bone specimens obtained from experimental animals. METHODS. The authors made UBV measurements in 40 femurs and tibias dissected from Sprague-Dawley rats (14 weeks-old, mean weight 290 g) and compared them with bone densitometric measurements made on the same material using dual-energy x-ray absorptiometry (DXA). RESULTS. The coefficient of variation for UBV measurements, based on values obtained in five femurs and five tibias at different times, was 0.2% and 03% respectively. Regression studies yielded a correlation between UBV and bone mineral density in femur of r = 0.87 (P < 0.0001) and with bone mineral content of r = 0.65 (P < 0.0001); in the tibia similar levels of significance were obtained. The correlation between femur weight and UBV was r = 0.51 (P < 0.0005) and with bone mineral content it was r = 0.79 (P < 0.0001). Partial correlation between UBV and femur bone mineral density, with respect to bone weight, was r = 0.68 (P < 0.001), and with femur bone mineral content was r = 0.71 (P < 0.0001). In the tibia measurements were similarly significant. CONCLUSIONS. Measurements of bone mass made with ultrasound transmission velocity are precise correlate well with DXA measurements.
引用
收藏
页码:114 / 117
页数:4
相关论文
共 50 条
  • [1] Ultrasound velocity and dual-energy X-ray absorptiometry in normal and pagetic bone
    Pande, KC
    Bernard, J
    McCloskey, EV
    de Takats, D
    Kanis, JA
    BONE, 2000, 26 (05) : 525 - 528
  • [2] Dual-energy X-ray absorptiometry for histologic bone sections
    Denissen, H
    DeBlieck, J
    Verhey, H
    Klein, C
    VanLingen, A
    JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 (05) : 638 - 644
  • [3] Dual-energy X-ray absorptiometry and bone density measurement
    Jonsson, K.
    ACTA RADIOLOGICA, 2007, 48 (02) : 123 - 123
  • [4] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE RAT - ACCURACY, PRECISION, AND MEASUREMENT OF BONE LOSS
    GRIFFIN, MG
    KIMBLE, R
    HOPFER, W
    PACIFICI, R
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 (07) : 795 - 800
  • [5] CALIBRATION OF DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR BONE-DENSITY
    MAZESS, RB
    TREMPE, JA
    BISEK, JP
    HANSON, JA
    HANS, D
    JOURNAL OF BONE AND MINERAL RESEARCH, 1991, 6 (08) : 799 - 806
  • [6] Dual-energy X-ray absorptiometry registers bone mineral in the liver
    Koufakis, M
    Söderborg, B
    Kallner, G
    Magi, A
    Svensson, U
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2001, 13 (05) : 523 - 528
  • [7] Quantification of bone healing with dual-energy X-ray absorptiometry.
    denBoer, FC
    vanLingen, A
    Patka, P
    Haarman, HJTM
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 1260 - 1260
  • [8] Comparison of Bone Health Parameters Using Qualitative Ultrasound And Dual-Energy X-Ray Absorptiometry
    Wherry, Sarah J.
    Swan, Pamela D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 237 - 237
  • [9] RELIABILITY AND RELATIONSHIP OF ULTRASOUND AND DUAL-ENERGY X-RAY ABSORPTIOMETRY (DEXA) FOR THE ASSESSMENT OF BONE QUALITY
    BOGDANFFY, GM
    GRIFFITH, SL
    OHNMEISS, DD
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 : S404 - S404
  • [10] Comparison of Histomorphometric Descriptors of Bone Architecture with Dual-Energy X-ray Absorptiometry for Assessing Bone Loss in the Orchidectomized Rat
    H. Libouban
    M. F. Moreau
    E. Legrand
    M. Audran
    M. F. Basle´
    D. Chappard
    Osteoporosis International, 2002, 13 : 422 - 428