Photothermal biosensor for HPV16 based on strand-displacement amplification and gold nanoparticles using a thermometer as readout

被引:5
|
作者
Yan, Bingyan [1 ,2 ]
Li, Min [3 ]
Luo, Fang [2 ]
Jin, XiaoYa [1 ]
Qiu, Bin [2 ]
Lin, Zhenyu [2 ]
机构
[1] Wenzhou Med Univ, Dept Infect Dis, Key Lab Diag & Controlment Dev Chron Liver Dis Zh, Affiliated Hosp 1, Wenzhou 325025, Peoples R China
[2] Fuzhou Univ, Key Lab Anal & Detect Food Safety, Coll Chem, Minist Educ,Key Lab Analyt Sci Food Safety & Biol, 2 Xue Yuan Rd, Fuzhou 350116, Fujian, Peoples R China
[3] Fujian Med Univ, Fujian Prov Hosp, Dept Gen Med, Prov Clin Med Coll 13, Fuzhou 350001, Fujian, Peoples R China
关键词
Photothermal effect; Gold nanoparticle; Strand-displacement amplification; Human papillomavirus; Thermometer; ELECTROCHEMICAL BIOSENSOR; AGGREGATION;
D O I
10.1007/s00604-022-05522-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold nanoparticles (AuNPs) in aggregated state have a strong near infrared region (NIR) absorption and the causes a much stronger photothermal effect than that of the dispersed AuNPs. Strand-displacement amplification (SDA) can produce large amount of single-stranded DNA (ssDNA), which in turn effectively prevent AuNPs from aggregation. In this study, these characteristics had been applied to design a photothermal biosensor for human papilloma virus (HPV and HPV16 were chosen as model target) detection. In the absence of HPV16, AuNPs was in the aggregated state and large temperature rise can be detected after the irradiation by 808 nm laser. The presence of HPV16 triggers the SDA reaction with the help of Bst DNA polymerase and Nt.BstNBI nicking endonuclease resulting in the production of large amounts of ssDNA; this protects unmodified AuNPs from salt-induced aggregation. Therefore, AuNPs was in a dispersed state and the temperature change was not significant after the irradiation of 808 nm laser. The difference of the temperature changing can be applied for the quantitative detection of HPV16 using a thermometer as readout. The linear response range is 1.0 fM similar to 50 pM with a detection limit of 0.3 fM. The proposed method has been applied to detect HPV16 in clinical cervical sample and is competent for clinical analysis.
引用
收藏
页数:9
相关论文
共 33 条
  • [21] Electrochemical aptamer-based determination of protein tyrosine kinase-7 using toehold-mediated strand displacement amplification on gold nanoparticles and graphene oxide
    Li, Zongbing
    Zhou, Zhengkun
    Xue, Ning
    Wu, Shujie
    Miao, Xiangmin
    MICROCHIMICA ACTA, 2019, 186 (11)
  • [22] Rapid and sensitive detection of Pseudomonas aeruginosa using multiple cross displacement amplification and gold nanoparticle-based lateral flow biosensor visualization
    Zhao, Fan
    Niu, Lina
    Nong, Jinqing
    Wang, Chunmei
    Wang, Jing
    Liu, Yan
    Gao, Naishu
    Zhu, Xiaoxue
    Wu, Lei
    Hu, Shoukui
    FEMS MICROBIOLOGY LETTERS, 2018, 365 (14)
  • [23] Rapid, ultrasensitive, and highly specific identification of Brucella abortus utilizing multiple cross displacement amplification combined with a gold nanoparticles-based lateral flow biosensor
    Yang, Xinggui
    Wang, Yue
    Liu, Ying
    Huang, Junfei
    Wei, Xiaoyu
    Tan, Qinqin
    Zeng, Xiaoyan
    Ying, Xia
    Li, Shijun
    FRONTIERS IN MICROBIOLOGY, 2022, 13
  • [24] Multiple Cross Displacement Amplification Coupled With Gold Nanoparticles-Based Lateral Flow Biosensor for Detection of the Mobilized Colistin Resistance Gene mcr-1
    Gong, Lin
    Liu, Ernan
    Che, Jie
    Li, Juan
    Liu, Xiaoli
    Xu, Huiqiong
    Liang, Jiansheng
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2019, 9
  • [25] Electrochemical lectin-based biosensor array for detection and discrimination of carcinoembryonic antigen using dual amplification of gold nanoparticles and horseradish peroxidase
    Zhao, Lingzhi
    Li, Congcong
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 235 : 575 - 582
  • [26] Ultra-sensitive electrochemical DNA biosensor based on signal amplification using gold nanoparticles modified with molybdenum disulfide, graphene and horseradish peroxidase
    Cao, Xiaoyu
    MICROCHIMICA ACTA, 2014, 181 (9-10) : 1133 - 1141
  • [27] Ultra-sensitive electrochemical DNA biosensor based on signal amplification using gold nanoparticles modified with molybdenum disulfide, graphene and horseradish peroxidase
    Xiaoyu Cao
    Microchimica Acta, 2014, 181 : 1133 - 1141
  • [28] Rapid Detection of Brucella spp. and Elimination of Carryover Using Multiple Cross Displacement Amplification Coupled With Nanoparticles-Based Lateral Flow Biosensor
    Li, Shijun
    Liu, Ying
    Wang, Yue
    Wang, Ming
    Liu, Chunting
    Wang, Yi
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2019, 9
  • [29] Molecular beacon based biosensor for the sequence-specific detection of DNA using DNA-capped gold nanoparticles-streptavidin conjugates for signal amplification
    Xian Fang
    Wei Jiang
    Xiaowei Han
    Yuzhong Zhang
    Microchimica Acta, 2013, 180 : 1271 - 1277
  • [30] Molecular beacon based biosensor for the sequence-specific detection of DNA using DNA-capped gold nanoparticles-streptavidin conjugates for signal amplification
    Fang, Xian
    Jiang, Wei
    Han, Xiaowei
    Zhang, Yuzhong
    MICROCHIMICA ACTA, 2013, 180 (13-14) : 1271 - 1277