One-step immunoassay of C-reactive protein using droplet microfluidics

被引:51
|
作者
Tang, Matthew Y. H. [1 ]
Shum, Ho Cheung [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Mech Engn, Pokfulam Rd, Hong Kong, Hong Kong, Peoples R China
[2] HKU Shenzhen Inst Res & Innovat HKU SIRI, Shenzhen 518000, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
CARDIOVASCULAR-DISEASE; HIGH-THROUGHPUT; PLATFORM; ELISA; RISK; INFLAMMATION; TECHNOLOGY; SYSTEM; CELLS;
D O I
10.1039/c6lc01121g
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a wash-free high-sensitivity immunoassay of C-reactive proteins with droplet microfluidics. Microbeads are encapsulated within droplets for the immunoassay, and the droplets are scanned by a fluorescence detection platform to quantify the amount of proteins captured on the microbeads. The limit of detection determined by our platform is 0.01 mu g mL(-1), which is ten times more sensitive than conventional high-sensitivity C-reactive protein assays. With the decrease in diffusion distance within droplets, the immunoassay requires only half of the time required for similar conventional approaches. This approach for carrying out immunoassays can potentially be applied to other biomarkers beyond C-reactive proteins.
引用
收藏
页码:4359 / 4365
页数:7
相关论文
共 50 条
  • [31] SINGLE-STEP PURIFICATION OF RAT C-REACTIVE PROTEIN AND GENERATION OF MONOSPECIFIC C-REACTIVE PROTEIN ANTIBODY
    PRUDEN, DJ
    CONNOLLY, KM
    STECHER, VJ
    JOURNAL OF CHROMATOGRAPHY, 1988, 437 (02): : 399 - 410
  • [32] One-step formation of multiple emulsions in microfluidics
    Abate, Adam R.
    Thiele, Julian
    Weitz, David A.
    LAB ON A CHIP, 2011, 11 (02) : 253 - 258
  • [33] Detection of C-Reactive Protein by Electrochemiluminescence-Based Droplet-Free Digital Immunoassay with Tyramide Signal Amplification
    Abe, Hiroya
    Nakamura, Shuri
    Ito, Kentaro
    Ino, Kosuke
    Liu, Zhengyi
    Sato, Shinichi
    Inoue, Kumi Y.
    Shiku, Hitoshi
    CHEMELECTROCHEM, 2025,
  • [34] IMMUNOASSAY METHODS FOR DETERMINATION OF SERUM C-REACTIVE PROTEIN-LEVELS
    MERLINI, G
    PAVESI, F
    BERGONZI, C
    BELLOTTI, V
    ZORZOLI, I
    VADACCA, G
    AGUZZI, L
    MORATTI, R
    RICERCA IN CLINICA E IN LABORATORIO, 1984, 14 (03): : 581 - 585
  • [35] MICROPARTICLE-ENHANCED NEPHELOMETRIC IMMUNOASSAY FOR HUMAN C-REACTIVE PROTEIN
    MONTAGNE, P
    LAROCHE, P
    CUILLIERE, ML
    VARCIN, P
    PAU, B
    DUHEILLE, J
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1992, 6 (01) : 24 - 29
  • [36] A Smartphone-based Diffusometric Immunoassay for Detecting C-Reactive Protein
    Chuang, Chih-Shen
    Deng, Chih-Zong
    Fang, Yi-Fan
    Jiang, Hong-Ren
    Tseng, Pao-Wei
    Sheen, Horn-Jiunn
    Fan, Yu-Jui
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [37] Latex piezoelectric immunoassay: Analysis of C-reactive protein in human serum
    Kurosawa, S
    Aizawa, H
    Yoshimoto, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (05) : 1256 - 1258
  • [38] A Smartphone-based Diffusometric Immunoassay for Detecting C-Reactive Protein
    Chih-Shen Chuang
    Chih-Zong Deng
    Yi-Fan Fang
    Hong-Ren Jiang
    Pao-Wei Tseng
    Horn-Jiunn Sheen
    Yu-Jui Fan
    Scientific Reports, 9
  • [39] Rapid automated high sensitivity enzyme immunoassay of C-reactive protein
    Wilkins, J
    Gallimore, JR
    Moore, EG
    Pepys, MB
    CLINICAL CHEMISTRY, 1998, 44 (06) : 1358 - 1361
  • [40] A new automated turbidimetric immunoassay for the measurement of canine C-reactive protein
    Pineiro, Matilde
    Pato, Raquel
    Soler, Lourdes
    Pena, Raquel
    Garcia, Natalia
    Torrente, Carlos
    Saco, Yolanda
    Lampreave, Fermin
    Bassols, Anna
    Canalias, Francesca
    VETERINARY CLINICAL PATHOLOGY, 2018, 47 (01) : 130 - 137