Voltage lead corrections for a pulse-driven ac Josephson voltage standard

被引:23
|
作者
van den Brom, Helko E. [1 ]
Houtzager, Ernest [1 ]
机构
[1] VSL BV, NL-2600 AR Delft, Netherlands
关键词
metrology; standards and calibration; basic electromagnetic quantities; measurements in electric variables; SYNTHESIZER; ERROR;
D O I
10.1088/0957-0233/23/12/124007
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We present measurements on a pulse-driven ac Josephson voltage standard (ACJVS) for frequencies up to 1 MHz. By automating our setup we were able to perform a systematic study of the frequency dependence of the ACJVS output. We show that the error caused by the voltage leads is the major error source when measuring at frequencies up to 1 MHz. The squared frequency dependence of the error, which is caused by a resonance in the circuit, allows us to make a correction that results in an uncertainty on the mu V V-1 level for frequencies up to at least 20 kHz.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Progress on the Opto-Electronic Bias for Pulse-Driven Josephson Voltage Standards at PTB
    Kraus, Marco
    Kieler, Oliver
    Behr, Ralf
    Palafox, Luis
    2024 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CPEM 2024, 2024,
  • [32] Realization of an Opto-Electronic Bias for Pulse-Driven Josephson Voltage Standards at PTB
    Herick, Jonas
    Palafox, Luis
    Bardalen, Eivind
    Bauer, Stephan
    Behr, Ralf
    Karlsen, Bjornar
    Kieler, Oliver
    Malmbekk, Helge
    2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [33] Progress on AC Voltage Measurement System with Josephson Voltage Standard
    Wang, Zengmin
    Li, Honghui
    Yang, Yan
    Gao, Yuan
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [34] Pulse driven Josephson voltage standard using modulated optical comb
    Urano, C.
    Kaneko, N.
    Maezawa, M.
    Itatani, T.
    Kiryu, S.
    8TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'07), 2008, 97
  • [35] Quantum Locking Range Effects in Pulse-Driven Josephson Junction Arrays for DC Voltage Generation
    Georgakopoulos, Dimitrios
    CPEM Digest (Conference on Precision Electromagnetic Measurements), 2024,
  • [36] Realization of a Phase Reference System Based on Two Synchronized Pulse-Driven Josephson Voltage Standards
    Bauer, Stephan
    Schmidt, Matthias
    Beug, Florian
    Herick, Jonas
    Kieler, Oliver
    Behr, Ralf
    2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [37] INVERSE AC JOSEPHSON EFFECT VOLTAGE STANDARD
    LEVINSEN, MT
    CHIAO, RY
    FELDMAN, MJ
    TUCKER, BA
    APPLIED PHYSICS LETTERS, 1977, 31 (11) : 776 - 778
  • [38] ESTABLISHING AN AC JOSEPHSON VOLTAGE STANDARD AT NRC
    Filipski, P. S.
    Boecker, M.
    Benz, S. P.
    Burroughs, C. J.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 22 - +
  • [39] Quantum Locking Range Effects in Pulse-Driven Josephson Junction Arrays for DC Voltage Generation
    Georgakopoulos, Dimitrios
    2024 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CPEM 2024, 2024,
  • [40] AC Josephson voltage standard: Progress report
    Hamilton, CA
    Burroughs, CJ
    Benz, SP
    Kinard, JR
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (02) : 224 - 228