Analysis of Waveform-Derived ORA Parameters in Early Forms of Keratoconus and Normal Corneas

被引:36
|
作者
Ventura, Bruna V. [1 ,2 ,3 ]
Machado, Aydano P. [1 ,3 ]
Ambrosio, Renato, Jr. [1 ,4 ,5 ]
Ribeiro, Guilherme [1 ,6 ]
Araujo, Luana N. [1 ,3 ]
Luz, Allan [1 ,4 ,5 ]
Lyra, Joao Marcelo [1 ,6 ]
机构
[1] Brazilian Study Grp Artificial Intelligence & Cor, Rio De Janeiro, Brazil
[2] Altino Ventura Fdn, Recife, PE, Brazil
[3] Univ Fed Alagoas, Maceio, Brazil
[4] Inst Olhos Renato Ambrosio, Rio De Janeiro, Brazil
[5] Univ Fed Sao Paulo, Sao Paulo, Brazil
[6] Univ Ciencias Saude Alagoas, Maceio, Brazil
关键词
OCULAR RESPONSE ANALYZER; INTRAOCULAR-PRESSURE; HYSTERESIS; CHILDREN; EYES;
D O I
10.3928/1081597X-20130819-05
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Depew, NY) performance in differentiating grades I and II keratoconus from normal corneas using 41 parameters individually and to assess the effect of analyzing all parameters together. METHODS: This study compared the mean value of 41 ORA parameters in grades I and II keratoconus with healthy age-matched control eyes. Only eyes with a central corneal thickness between 500 and 600 mu m were included. The area under the receiver operating characteristic curve was calculated for each of the 41 parameters independently and for all of the parameters together. RESULTS: This study included 136 eyes with normal corneas and 68 eyes with grades I and II keratoconus. When analyzed individually, four ORA parameters (p1area, p1area1, p2area, and p2area1) had an area under the curve greater than 0.900 for discriminating between both groups. The p2area was the parameter that achieved the largest area under the curve individually (0.931). The area under the curve increased to 0.978 when analyzing all parameters together. CONCLUSION: Alternative ORA parameters are better for differentiating grades I and II keratoconus from normal corneas than the four parameters originally available for ophthalmologists (corneal hysteresis, Goldmann-correlated intraocular pressure, corneal-compensated intraocular pressure, and corneal resistance factor). Although the ORA did not achieve 100% accuracy, the discrimination between these two groups was optimized by combining all parameters.
引用
收藏
页码:637 / +
页数:11
相关论文
共 23 条
  • [21] Computer assisted Doppler waveform analysis and ultrasound derived turbulence intensity ratios can predict early hyperplasia development in newly created vascular access fistula: Pilot study, methodology and analysis
    Bartlett, Matthew
    Diaz-Zuccarini, Vanessa
    Tsui, Janice
    JRSM CARDIOVASCULAR DISEASE, 2021, 10
  • [22] Diffusion-derived parameters in lesions, peri-lesion, and normal-appearing white matter in multiple sclerosis using tensor, kurtosis, and fixel-based analysis
    van der Weijden, Chris Wj
    van der Hoorn, Anouk
    Potze, Jan Hendrik
    Renken, Remco J.
    Borra, Ronald J. H.
    Dierckx, Rudi A. J. O.
    Gutmann, Ingomar W.
    Ouaalam, Hakim
    Karimi, Davood
    Gholipour, Ali
    Warfield, Simon K.
    de Vries, Erik F. J.
    Meilof, Jan F.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2022, 42 (11): : 2095 - 2106
  • [23] Speckle-tracking-derived strain and strain-rate analysis: a technique for the evaluation of early alterations in right ventricle systolic function in patients with systemic sclerosis and normal pulmonary artery pressure
    Matias, Carla
    de Isla, Leopoldo Perez
    Vasconcelos, Mariana
    Almeria, Carlos
    Rodrigo, Jose Luis
    Serra, Viviana
    Zamorano, Jose
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2009, 10 (02) : 129 - 134